header

Assessment of primary stability of immediate two- piece zirconium implants placed in fresh sockets in esthetic zone (quasi experimental design) / (Record no. 73871)

MARC details
000 -LEADER
fixed length control field 02594cam a2200313 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 190914s2018 ua dh f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.09.13.M.Sc.2018.Ai.A
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Aisha Khaled Mansour
245 10 - TITLE STATEMENT
Title Assessment of primary stability of immediate two- piece zirconium implants placed in fresh sockets in esthetic zone (quasi experimental design) /
Statement of responsibility, etc. Aisha Khaled Mansour ; Supervised Nader Nabil Elbokle , Mohammed Ashraf Ahmed
246 15 - VARYING FORM OF TITLE
Title proper/short title تقييم الثباتيه الفوريه لقطعتين من غرسات الزركونيوم توضع فى مآخذ جديدة فى المنطقه التجميليه
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Aisha Khaled Mansour ,
Date of publication, distribution, etc. 2018
300 ## - PHYSICAL DESCRIPTION
Extent 103 P. :
Other physical details charts , facsimiles ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Oral and Maxillofacial Surgery
520 ## - SUMMARY, ETC.
Summary, etc. This study was conducted to evaluate the primary stability of immediately placed two piece zirconium implants with autogenous bone graft through resonance frequency analysis. In this study 11 implants were placed in 3 males and 7 females with at least one remaining root in the anterior esthetic zone. The surgical procedures that were applied in this study were performed under local anesthesia. They included atraumatic extraction, drilling through the socket by subsequent drills according to the manufacturer{u2019}s instructions to the selected depth and width to achieve implant stability and maximum adaptation between the implant and socket wall. Stability of each implant was measured by Osstell ISQ immediately after implant placement and 4 months post the procedure before loading implant and abutment placement. No patient developed any post-operative serious complication that could affect implant success. All the 11 fixtures healed well with no infection or failure. We recorded only one implant that broke during placement without any excessive force or torque applied and it was taken out. The analysis of the effect of different variables on the implant stability showed that there was a strong correlation between primary stability and secondary stability
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Fresh sockets
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Immediate
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Zirconium
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Mohammed Ashraf Ahmed ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Nader Nabil Elbokle ,
Relator term
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Shimaa
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.09.13.M.Sc.2018.Ai.A 01010110079302000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.09.13.M.Sc.2018.Ai.A 01020110079302000 22.09.2023 CD - Rom 79302.CD