header

Standardized radiometric method for evaluating phototherapy irradiance measurements and its medical applications / (Record no. 73898)

MARC details
000 -LEADER
fixed length control field 02840cam a2200349 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223032359.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 190916s2019 ua dh f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level Ph.D
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.12.04.Ph.D.2019.Sa.S
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Samaa Medhat Abdelrehem Faramawy
245 10 - TITLE STATEMENT
Title Standardized radiometric method for evaluating phototherapy irradiance measurements and its medical applications /
Statement of responsibility, etc. Samaa Medhat Abdelrehem Faramawy ; Supervised Ahmed S. Monem , Reem H. Elgebaly , Alaa Eldin A. Abdelmageed
246 15 - VARYING FORM OF TITLE
Title proper/short title طريقة راديومترية عيارية لتقييم قياس التساقطية الضوئية العلاجية وتطبيقاتها الطبية
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Samaa Medhat Abd Elrehem Faramawy ,
Date of publication, distribution, etc. 2019
300 ## - PHYSICAL DESCRIPTION
Extent 200 P. :
Other physical details charts , facsimiles ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (Ph.D.) - Cairo University - Faculty of Science - Department of Biophysics
520 ## - SUMMARY, ETC.
Summary, etc. The performance of numerous phototherapy devices, developed and marketed, generally has not been adequately tested for irradiance delivery. The safety and efficiency in the operation of these devices remain one of the essential requirements for public health and concern. This thesis investigates the radiometric properties of different therapeutic devices currently used for phototherapy in Egypt. In order to achieve their effectiveness, we have established a standardized radiometric procedure based on evaluating the phototherapy devices through testing their irradiance and uniformity. About 25-50% of all full term neonates and 70-80% of prematurely newborn infants suffer from hyperbilirubinemia during their early days of life.The bilirubin molecule, which is responsible for the yellowness skin appearance of babies with jaundice, is extremely sensitive to optical energy within the spectrum radiation range 400 -500 nm.The effectiveness of phototherapy treatment depends directly on the rate of energy emitted from light source expressed in terms of irradiance W/m2. This effectiveness of neonatal hyperbilirubinaemia treatment depends directly on the wavelength and intensity (irradiance) of the light emitted during phototherapy expressed by spectral irradiance in W/m2/nm, to achieve a therapeutic reduction in the bilirubin concentration in the blood
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Irradiance measurement
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Parameters influence the irradiance measurements and uniformity
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Phototherapy
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Ahmed S. Monem ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Alaa Eldin A. Abdelmageed ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Reem H. Elgebaly ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Shimaa
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.12.04.Ph.D.2019.Sa.S 01010110079307000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.12.04.Ph.D.2019.Sa.S 01020110079307000 22.09.2023 CD - Rom 79307.CD