Standardized radiometric method for evaluating phototherapy irradiance measurements and its medical applications / (Record no. 73898)
[ view plain ]
000 -LEADER | |
---|---|
fixed length control field | 02840cam a2200349 a 4500 |
003 - CONTROL NUMBER IDENTIFIER | |
control field | EG-GiCUC |
005 - DATE AND TIME OF LATEST TRANSACTION | |
control field | 20250223032359.0 |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
fixed length control field | 190916s2019 ua dh f m 000 0 eng d |
040 ## - CATALOGING SOURCE | |
Original cataloging agency | EG-GiCUC |
Language of cataloging | eng |
Transcribing agency | EG-GiCUC |
041 0# - LANGUAGE CODE | |
Language code of text/sound track or separate title | eng |
049 ## - LOCAL HOLDINGS (OCLC) | |
Holding library | Deposite |
097 ## - Thesis Degree | |
Thesis Level | Ph.D |
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) | |
Classification number | Cai01.12.04.Ph.D.2019.Sa.S |
100 0# - MAIN ENTRY--PERSONAL NAME | |
Personal name | Samaa Medhat Abdelrehem Faramawy |
245 10 - TITLE STATEMENT | |
Title | Standardized radiometric method for evaluating phototherapy irradiance measurements and its medical applications / |
Statement of responsibility, etc. | Samaa Medhat Abdelrehem Faramawy ; Supervised Ahmed S. Monem , Reem H. Elgebaly , Alaa Eldin A. Abdelmageed |
246 15 - VARYING FORM OF TITLE | |
Title proper/short title | طريقة راديومترية عيارية لتقييم قياس التساقطية الضوئية العلاجية وتطبيقاتها الطبية |
260 ## - PUBLICATION, DISTRIBUTION, ETC. | |
Place of publication, distribution, etc. | Cairo : |
Name of publisher, distributor, etc. | Samaa Medhat Abd Elrehem Faramawy , |
Date of publication, distribution, etc. | 2019 |
300 ## - PHYSICAL DESCRIPTION | |
Extent | 200 P. : |
Other physical details | charts , facsimiles ; |
Dimensions | 25cm |
502 ## - DISSERTATION NOTE | |
Dissertation note | Thesis (Ph.D.) - Cairo University - Faculty of Science - Department of Biophysics |
520 ## - SUMMARY, ETC. | |
Summary, etc. | The performance of numerous phototherapy devices, developed and marketed, generally has not been adequately tested for irradiance delivery. The safety and efficiency in the operation of these devices remain one of the essential requirements for public health and concern. This thesis investigates the radiometric properties of different therapeutic devices currently used for phototherapy in Egypt. In order to achieve their effectiveness, we have established a standardized radiometric procedure based on evaluating the phototherapy devices through testing their irradiance and uniformity. About 25-50% of all full term neonates and 70-80% of prematurely newborn infants suffer from hyperbilirubinemia during their early days of life.The bilirubin molecule, which is responsible for the yellowness skin appearance of babies with jaundice, is extremely sensitive to optical energy within the spectrum radiation range 400 -500 nm.The effectiveness of phototherapy treatment depends directly on the rate of energy emitted from light source expressed in terms of irradiance W/m2. This effectiveness of neonatal hyperbilirubinaemia treatment depends directly on the wavelength and intensity (irradiance) of the light emitted during phototherapy expressed by spectral irradiance in W/m2/nm, to achieve a therapeutic reduction in the bilirubin concentration in the blood |
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE | |
Additional physical form available note | Issued also as CD |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Irradiance measurement |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Parameters influence the irradiance measurements and uniformity |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Phototherapy |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Ahmed S. Monem , |
Relator term | |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Alaa Eldin A. Abdelmageed , |
Relator term | |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Reem H. Elgebaly , |
Relator term | |
856 ## - ELECTRONIC LOCATION AND ACCESS | |
Uniform Resource Identifier | <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a> |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) | |
Cataloger | Nazla |
Reviser | Revisor |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) | |
Cataloger | Shimaa |
Reviser | Cataloger |
942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
Source of classification or shelving scheme | Dewey Decimal Classification |
Koha item type | Thesis |
Source of classification or shelving scheme | Not for loan | Home library | Current library | Date acquired | Full call number | Barcode | Date last seen | Koha item type | Copy number |
---|---|---|---|---|---|---|---|---|---|
Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | قاعة الرسائل الجامعية - الدور الاول | 11.02.2024 | Cai01.12.04.Ph.D.2019.Sa.S | 01010110079307000 | 22.09.2023 | Thesis | ||
Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | مخـــزن الرســائل الجـــامعية - البدروم | 11.02.2024 | Cai01.12.04.Ph.D.2019.Sa.S | 01020110079307000 | 22.09.2023 | CD - Rom | 79307.CD |