MARC details
000 -LEADER |
fixed length control field |
02564cam a2200325 a 4500 |
003 - CONTROL NUMBER IDENTIFIER |
control field |
EG-GiCUC |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
fixed length control field |
190930s2019 ua dh f m 000 0 eng d |
040 ## - CATALOGING SOURCE |
Original cataloging agency |
EG-GiCUC |
Language of cataloging |
eng |
Transcribing agency |
EG-GiCUC |
041 0# - LANGUAGE CODE |
Language code of text/sound track or separate title |
eng |
049 ## - LOCAL HOLDINGS (OCLC) |
Holding library |
Deposite |
097 ## - Thesis Degree |
Thesis Level |
Ph.D |
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) |
Classification number |
Cai01.13.13.Ph.D.2019.Sh.E |
100 0# - MAIN ENTRY--PERSONAL NAME |
Personal name |
Shaker Abdelwahab Shaker Gelany |
245 10 - TITLE STATEMENT |
Title |
Establishment and characterization of reference system for calibration of dynamic pressure sensors / |
Statement of responsibility, etc. |
Shaker Abdelwahab Shaker Gelany ; Supervised Tarek Abdelsadek Osman , Abdelaziz Mahmoud , Alaaeldin Abdelfattah Eltawil |
246 15 - VARYING FORM OF TITLE |
Title proper/short title |
تأسيس وتوصيف نظام مرجعي لمعايرة حساسات قياس الضغط الديناميكي |
260 ## - PUBLICATION, DISTRIBUTION, ETC. |
Place of publication, distribution, etc. |
Cairo : |
Name of publisher, distributor, etc. |
Shaker Abdelwahab Shaker Gelany , |
Date of publication, distribution, etc. |
2019 |
300 ## - PHYSICAL DESCRIPTION |
Extent |
77 P. : |
Other physical details |
charts , facsimiles ; |
Dimensions |
30cm |
502 ## - DISSERTATION NOTE |
Dissertation note |
Thesis (Ph.D.) - Cairo University - Faculty of Engineering - Department of Mechanical Design and Production |
520 ## - SUMMARY, ETC. |
Summary, etc. |
Measurement standards for dynamic pressure and its traceability to the International System of Units (SI) is a novel field in metrology. Therefore, such standards are not commonly found in National Metrology Institutes (NMIs) that could enable calibration of modern dynamic pressure transducers. For several industrial fields using dynamic pressure technologies, this, in turn, limits quality assurance.Due to, the lack of traceability in the dynamic pressure measurements, the dynamic pressure sensors and transducers are calibrated using static or quasi-static methods. This may lead to significant errors in measurements as the behavior of the sensor in the dynamic mode differs from the static mode.In response to this problem, this study has been dedicated to establish and investigate a primary standard system for dynamic pressure measurements up to 100 MPa with relative uncertainty as low as 1.5 %. This new reference dynamic pressure standard is of crucial importance to develop calibration methods for dynamic pressure transducers. Furthermore, it provides the metrological basis for the dynamic pressure technologies such as automotive industries, military, aerodynamics, medicine, and material testing |
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE |
Additional physical form available note |
Issued also as CD |
653 #4 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
Dynamic calibration |
653 #4 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
Dynamic pressure |
653 #4 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
Falling mass |
700 0# - ADDED ENTRY--PERSONAL NAME |
Personal name |
Abdelaziz Mahmoud , |
Relator term |
|
700 0# - ADDED ENTRY--PERSONAL NAME |
Personal name |
Alaaeldin Abdelfattah Eltawil , |
Relator term |
|
700 0# - ADDED ENTRY--PERSONAL NAME |
Personal name |
Tarek Abdelsadek Osman , |
Relator term |
|
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) |
Cataloger |
Nazla |
Reviser |
Revisor |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) |
Cataloger |
Shimaa |
Reviser |
Cataloger |
942 ## - ADDED ENTRY ELEMENTS (KOHA) |
Source of classification or shelving scheme |
Dewey Decimal Classification |
Koha item type |
Thesis |