header

Retrofitting strategy for building envelop in arid climates to reduce electricity consumption and enhance thermal comfort / (Record no. 74272)

MARC details
000 -LEADER
fixed length control field 02108cam a2200337 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223032410.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 191001s2019 ua a f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level Ph.D
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.13.02.Ph.D.2019.Ah.R
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Ahmed Elsayed Abdelsalam
245 10 - TITLE STATEMENT
Title Retrofitting strategy for building envelop in arid climates to reduce electricity consumption and enhance thermal comfort /
Statement of responsibility, etc. Ahmed Elsayed Abdelsalam ; Supervised Sherine M. Wahba , Basil A. Kamel
246 15 - VARYING FORM OF TITLE
Title proper/short title أستراتيجية تغيير الغلاف الخارجي للمباني في الأقليم الحار الجاف لتخفيض أستهلاكات الطاقه و تحسيين الراحة الحرارية
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Ahmed Elsayed Abdelsalam ,
Date of publication, distribution, etc. 2019
300 ## - PHYSICAL DESCRIPTION
Extent 81 P. :
Other physical details ill. ;
Dimensions 30cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (Ph.D.) - Cairo University - Faculty of Engineering - Department of Architectural Engineering
520 ## - SUMMARY, ETC.
Summary, etc. This thesis represents the potential of vegetative layers in saving electricity consumption and reducing annual CO2 emissions in arid climates. Experiments are performed on neighborhood in Cairo, with a base case control that uses a traditional external materials. Cairo climatic zone was simulated. Costs for green-layer saving potentials were estimated according to the Egyptian electricity consumption calculator, other parameters as retrofit potential. The results demonstrate the economic benefits of using a green-layer under different design situations and provide guidance for the selection and layer systems efficiency in similar climates. Savings varied from 17% to 25% compared to traditional external building material
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Energy Consumption
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Green walls
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Green-roofs
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Basil A. Kamel ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Sherine M. Wahba ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Asmaa
Reviser Cataloger
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.13.02.Ph.D.2019.Ah.R 01010110079271000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.13.02.Ph.D.2019.Ah.R 01020110079271000 22.09.2023 CD - Rom 79271.CD