Predictive circuit modeling of total ionizing dose effects on ِbulk cmos technologies / (Record no. 74274)
[ view plain ]
000 -LEADER | |
---|---|
fixed length control field | 02744cam a2200349 a 4500 |
003 - CONTROL NUMBER IDENTIFIER | |
control field | EG-GiCUC |
005 - DATE AND TIME OF LATEST TRANSACTION | |
control field | 20250223032410.0 |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
fixed length control field | 191001s2019 ua do f m 000 0 eng d |
040 ## - CATALOGING SOURCE | |
Original cataloging agency | EG-GiCUC |
Language of cataloging | eng |
Transcribing agency | EG-GiCUC |
041 0# - LANGUAGE CODE | |
Language code of text/sound track or separate title | eng |
049 ## - LOCAL HOLDINGS (OCLC) | |
Holding library | Deposite |
097 ## - Thesis Degree | |
Thesis Level | M.Sc |
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) | |
Classification number | Cai01.13.08.M.Sc.2019.He.P |
100 0# - MAIN ENTRY--PERSONAL NAME | |
Personal name | Hesham Hassan Hassan Salah Eldin Shaker |
245 10 - TITLE STATEMENT | |
Title | Predictive circuit modeling of total ionizing dose effects on ِbulk cmos technologies / |
Statement of responsibility, etc. | Hesham Hassan Hassan Salah Eldin Shaker ; Supervised Serag Eldin Habib , Mohammed Refky Amin , Alaa Abdelwahab Saleh |
246 15 - VARYING FORM OF TITLE | |
Title proper/short title | نمذجة تنبؤية لتأثيرات الجرعة المؤينة الكلية على تقنيات الترانزيستور ذى المعدن-الأكسيد-شبه الموصل |
260 ## - PUBLICATION, DISTRIBUTION, ETC. | |
Place of publication, distribution, etc. | Cairo : |
Name of publisher, distributor, etc. | Hesham Hassan Hassan Salah Eldin Shaker , |
Date of publication, distribution, etc. | 2019 |
300 ## - PHYSICAL DESCRIPTION | |
Extent | 159 P. : |
Other physical details | charts , photographs ; |
Dimensions | 30cm |
502 ## - DISSERTATION NOTE | |
Dissertation note | Thesis (M.Sc.) - Cairo University - Faculty of Engineering - Department of Electronics and Communications |
520 ## - SUMMARY, ETC. | |
Summary, etc. | Most activities inside nuclear facilities are carried out in well-shielded areas to achieve the needed safety requirements against the exposure to ionizing radiation. This implies the necessity of employment of remote inspection and handling electronic equipment inside these areas. Therefore, these electronic equipment should be radiation tolerant to be able to work properly over its expected lifetime. The gamma rays are the main threatening ionizing radiation on electronic equipment mounted in nuclear facilities. Total Ionizing Dose (TID) introduced by the gamma radiation into silicon dioxide portions of MOS devices can cause their functionality failure. This work discusses a modeling methodology of the TID effects. These effects are introduced due to the absorption of gamma rays into shallow trench isolation oxides in bulk CMOS devices. The benefit of this modeling methodology is to provide the circuit designers with a tool to test the performance of their circuits at high absorbed doses and to develop radiation tolerant circuit designs suitable for different nuclear facilities. This modeling approach is applied to 130nm predictive technology model for bulk FET devices as a case study and the results show a good agreement with published measured data |
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE | |
Additional physical form available note | Issued also as CD |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Gamma rays |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Nuclear facilities |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Total ionizing dose |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Alaa Abdelwahab Saleh , |
Relator term | |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Mohammed Refky Amin , |
Relator term | |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Serag Eldin Habib , |
Relator term | |
856 ## - ELECTRONIC LOCATION AND ACCESS | |
Uniform Resource Identifier | <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a> |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) | |
Cataloger | Nazla |
Reviser | Revisor |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) | |
Cataloger | Samia |
Reviser | Cataloger |
942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
Source of classification or shelving scheme | Dewey Decimal Classification |
Koha item type | Thesis |
Source of classification or shelving scheme | Not for loan | Home library | Current library | Date acquired | Full call number | Barcode | Date last seen | Koha item type | Copy number |
---|---|---|---|---|---|---|---|---|---|
Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | قاعة الرسائل الجامعية - الدور الاول | 11.02.2024 | Cai01.13.08.M.Sc.2019.He.P | 01010110079442000 | 22.09.2023 | Thesis | ||
Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | مخـــزن الرســائل الجـــامعية - البدروم | 11.02.2024 | Cai01.13.08.M.Sc.2019.He.P | 01020110079442000 | 22.09.2023 | CD - Rom | 79442.CD |