header

Comparative study of conventional versus flexible mandibular single complete denture : (Record no. 74316)

MARC details
000 -LEADER
fixed length control field 03254cam a2200337 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223032412.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 191007s2019 ua dh f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.09.09.M.Sc.2019.Ma.C
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Marianne Azer Fouad
245 10 - TITLE STATEMENT
Title Comparative study of conventional versus flexible mandibular single complete denture :
Remainder of title Randomized clinical trial /
Statement of responsibility, etc. Marianne Azer Fouad ; Supervised Essam Adel Aziz , Ahmed Emad Fayyad
246 15 - VARYING FORM OF TITLE
Title proper/short title دراسة مقارنة للأطقم السنية الفكية التقليدية مقابل الأطقم السنية الفكية المرنة فى الأطقم الوحيدة السفلية الكاملة
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Marianne Azer Fouad ,
Date of publication, distribution, etc. 2019
300 ## - PHYSICAL DESCRIPTION
Extent 70 P. :
Other physical details charts , facsimiles ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontics
520 ## - SUMMARY, ETC.
Summary, etc. Single Mandibular denture is a condition in which edentulous mandibular arch is opposing maxillary teeth. It is common to find patients with single mandibular dentures but it is a difficult and challenging case. Patients have expectations of receiving a retentive and well-fitting mandibular denture, however the reality of meeting that outcome is generally variable. For decades, polymethyl methacrylate (PMMA) has been used to fabricate dentures. The PMMA acrylic denture base prostheses have their own advantages and disadvantages. Some problems with PMMA prosthesis are insertion in bilateral bony undercut areas and allergy to methyl methacrylate monomer.The difficulties encountered by such patients are overcome by either using implant or soft denture base material. Implants are highly effective to reach satisfactory prognosis, but they are not a viable solution for all edentulous patients because of medical, psychological, and {uFB01}nancial constraints.Soft denture liner and flexible denture both share the merits of viscoelastic grip properties and damping effect against heavy masticatory load, yet flexible denture base has prolonged life span and minimal chair side adjustment.This brings us to the question, which is better in lower single denture cases regarding patient satisfaction, to use combined conventional denture base material relined by soft liner or flexible denture base material?To answer this question, research was conducted on 20 patients from the outpatient removable prosthodontics clinic, Faculty of Dentistry, Cairo University. Patients were randomly selected and grouped into two groups of 10 patients each; one group received conventional mandibular single dentures with soft liner. The other group received flexible single dentures. A follow up was done at 3 and 6 months after denture delivery
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Polymethyl methacrylate (PMMA)
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Single complete denture
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Versus flexible mandibular
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Ahmed Emad Fayyad ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Essam Adel Aziz ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Shimaa
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.09.09.M.Sc.2019.Ma.C 01010110079516000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.09.09.M.Sc.2019.Ma.C 01020110079516000 22.09.2023 CD - Rom 79516.CD