header

Axillary ultrasound versus traditional ultrasound on functional ability of patient with adhesive capsulitis / (Record no. 75446)

MARC details
000 -LEADER
fixed length control field 02891cam a2200349 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223032447.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 191125s2019 ua dh f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.21.09.M.Sc.2019.Af.A
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Afnan Hamdy Abdelghny Ali Elfol
245 10 - TITLE STATEMENT
Title Axillary ultrasound versus traditional ultrasound on functional ability of patient with adhesive capsulitis /
Statement of responsibility, etc. Afnan Hamdy Abdelghny Ali Elfol ; Supervised Abeer Abdelrahman Mohamed , Ali Mohamed Elgeoushy , Marwa Shafiek Mustafa
246 15 - VARYING FORM OF TITLE
Title proper/short title الموجات فوق الصوتية أبطى مقابل الموجات الفوق الصوتية التقليدية على القدرة الوظيفية لدى مرضى التهاب المحفظة اللاصق
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Afnan Hamdy Abdelghny Ali Elfol ,
Date of publication, distribution, etc. 2019
300 ## - PHYSICAL DESCRIPTION
Extent 109 P. :
Other physical details charts , facsimiles ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Physical Therapy - Department of Basic Sciences
520 ## - SUMMARY, ETC.
Summary, etc. Background: Adhesive capsulitis is a painful and disabling disorder of unclear cause in the shoulder. It restricts joint motion and cause chronic pain. Purpose: to investigate and compare the effect of axillary ultrasound application versus traditional ultrasound on functional ability in patient with adhesive capsulitis. Subjects and methods: Thirty patients of both sex with unilateral adhesive capsulitis had been participated and recruited from physical therapy department of Al Azhar university specialized hospital. Patients were randomly divided into two equal group{u2019}s number: Group (A) (Axillary ultrasound group): It composed of 15 patients who received axillary ultrasound in addition to physical therapy treatment. Group (B) (Traditional Ultrasound group): It composed of 15 patients who received traditional ultrasound in addition to physical therapy treatment. Patients in both groups received ultrasound according to the following specification: medium transducer,3MHz pulsed type (1:1), and 1.5 W/Cm applied for 10 minutes. In both group, Functional activity was measured by disabilities of the arm, shoulder and hand (DASH) questionnaire. Shoulder Flexion, abduction and external rotation range of motion were measured by digital inclinometer. Pain intensity was measured by visual analoug scale(VAS)before and after four weeks of treatment
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Adhesive Capsulitis
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Axillary ultrasound
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Traditional ultrasound
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Abeer Abdelrahman Mohamed ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Ali Mohamed Elgeoushy ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Marwa Shafiek Mustafa ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Asmaa
Reviser Cataloger
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.21.09.M.Sc.2019.Af.A 01010110080181000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.21.09.M.Sc.2019.Af.A 01020110080181000 22.09.2023 CD - Rom 80181.CD