Comparative study between US and CT in assessment of stable patients in blunt abdomminal trauma / (Record no. 75569)
[ view plain ]
000 -LEADER | |
---|---|
fixed length control field | 02315cam a2200325 a 4500 |
003 - CONTROL NUMBER IDENTIFIER | |
control field | EG-GiCUC |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
fixed length control field | 191201s2019 ua dh f m 000 0 eng d |
040 ## - CATALOGING SOURCE | |
Original cataloging agency | EG-GiCUC |
Language of cataloging | eng |
Transcribing agency | EG-GiCUC |
041 0# - LANGUAGE CODE | |
Language code of text/sound track or separate title | eng |
049 ## - LOCAL HOLDINGS (OCLC) | |
Holding library | Deposite |
097 ## - Thesis Degree | |
Thesis Level | M.Sc |
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) | |
Classification number | Cai01.11.31.M.Sc.2019.Mo.C |
100 0# - MAIN ENTRY--PERSONAL NAME | |
Personal name | Mohamed Abdelkader Abdelsattar Hashem |
245 10 - TITLE STATEMENT | |
Title | Comparative study between US and CT in assessment of stable patients in blunt abdomminal trauma / |
Statement of responsibility, etc. | Mohamed Abdelkader Abdelsattar Hashem ; Supervised Hamed Sameer Elghawaby , Maryse Youssef Awadallah , Ahmed Maher Hassan |
246 15 - VARYING FORM OF TITLE | |
Title proper/short title | مقارنة بين فحصى الموجات فوق الصوتية والأشعة المقطعية فى تقييم المرضى المستقرين فى حالات الصدمات البطنية الثلمة |
260 ## - PUBLICATION, DISTRIBUTION, ETC. | |
Place of publication, distribution, etc. | Cairo : |
Name of publisher, distributor, etc. | Mohamed Abdelkader Abdelsattar Hashem , |
Date of publication, distribution, etc. | 2019 |
300 ## - PHYSICAL DESCRIPTION | |
Extent | 107 P. : |
Other physical details | charts , facsimiles ; |
Dimensions | 25cm |
502 ## - DISSERTATION NOTE | |
Dissertation note | Thesis (M.Sc.) - Cairo University - Faculty of Medicine - Department of Radio-diagnosis |
520 ## - SUMMARY, ETC. | |
Summary, etc. | Background: Assessment of blunt abdominal trauma patients is often difficult by clinical means alone. Laboratory tests and imaging studies are cornerstones for evaluation. According to The Eastern Association for Surgery of Trauma [EAST] guidelines, US and CT can be used in assessing vitally stable patients. The ultimate goal of US and CT is to detect hemoperitoneum and visceral organ injury. Because of radiation hazards and high cost of CT scans, many studies tried to use US as the sole imaging modality in blunt abdominal trauma [BAT]. Our study evaluated US for detection of hemoperitoneum and organ injury against CT as the gold standard in BAT. Methods: Our study included 60 patients presenting to ER as victims of BAT in a hemodynamically stable condition. After primary survey and clinical assessment, US was done for detection of hemoperitoneum and organ injury. CT scan was done for confirmation of US findings |
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE | |
Additional physical form available note | Issued also as CD |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | CT |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Stable |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | US |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Ahmed Maher Hassan , |
Relator term | |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Hamed Sameer Elghawaby , |
Relator term | |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Maryse Youssef Awadallah , |
Relator term | |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) | |
Cataloger | Asmaa |
Reviser | Cataloger |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) | |
Cataloger | Nazla |
Reviser | Revisor |
942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
Source of classification or shelving scheme | Dewey Decimal Classification |
Koha item type | Thesis |
Source of classification or shelving scheme | Not for loan | Home library | Current library | Date acquired | Full call number | Barcode | Date last seen | Koha item type | Copy number |
---|---|---|---|---|---|---|---|---|---|
Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | قاعة الرسائل الجامعية - الدور الاول | 11.02.2024 | Cai01.11.31.M.Sc.2019.Mo.C | 01010110080200000 | 22.09.2023 | Thesis | ||
Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | مخـــزن الرســائل الجـــامعية - البدروم | 11.02.2024 | Cai01.11.31.M.Sc.2019.Mo.C | 01020110080200000 | 22.09.2023 | CD - Rom | 80200.CD |