header

Evaluation and optimization of CT-based attenuation correction in myocardial perfusion tomographic imaging / (Record no. 75601)

MARC details
000 -LEADER
fixed length control field 02837cam a2200325 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 191202s2019 ua do f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.12.04.M.Sc.2019.Ta.E
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Taher Hosny Abdelhamid Ali
245 10 - TITLE STATEMENT
Title Evaluation and optimization of CT-based attenuation correction in myocardial perfusion tomographic imaging /
Statement of responsibility, etc. Taher Hosny Abdelhamid Ali ; Supervised Wael M. Elshemey , Magdy M. Khalil , Abdo A. Elfiky
246 15 - VARYING FORM OF TITLE
Title proper/short title تقييم و تحسين التصوير المقطعى لتصوير تروية عضلة القلب المعتمد على تصحيح التوهين بالتصوير المقطعى المحسوب
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Taher Hosny Abdelhamid Ali ,
Date of publication, distribution, etc. 2019
300 ## - PHYSICAL DESCRIPTION
Extent 88 P. :
Other physical details charts , photographs ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Science - Department of Biophysics
520 ## - SUMMARY, ETC.
Summary, etc. SPECT myocardial perfusion imaging (SPECT MPI) is a widely used and well-established method for the evaluation of patients with known or suspected coronary artery disease (CAD). The integration of SPECT and CT (low-dose multi-slice CT) can improve the quality of MPI by enabling attenuation correction from CT-mapping of the thorax. Collimator depth dependent, tissue attenuation, and scattered photons are the main image degrading factors in nuclear medicine procedures. Recently, iterative reconstruction algorithms include corrections in the clinical procedures, thus improving imaging quality and diagnostic accuracy. To evaluate the impact of iterative reconstruction corrected for attenuation, scatter and collimator depth dependent, cardiac phantom of 110 ml volume and wall thickness of 10mm was used. Further, two solid defects (transmural 45{u00B0}x 1.5 cm and non-transmural 60{u00B0}x 2 cm and 5 mm wall thickness) was inserted and the whole phantom located inside available cylindrical phantom. Clinically relevant activity was injected into myocardium walls and background. Clinical standard protocol was performed with SPECT imaging scan. Different acquisition parameters (e.g. time/projection and number of projections) were applied. Reconstruction was done applying conventional method and iterative reconstruction with different combination of corrections. Figures of merit were used to evaluate MPI image quality
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Coronary artery disease (CAD)
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term CT-based attenuation correction
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term SPECT myocardial perfusion imaging (SPECT MPI)
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Abdo A. Elfiky ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Magdy M. Khalil ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Wael M. Elshemey ,
Relator term
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Samia
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.12.04.M.Sc.2019.Ta.E 01010110080021000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.12.04.M.Sc.2019.Ta.E 01020110080021000 22.09.2023 CD - Rom 80021.CD