header

False trips in gas power plant due to transient voltage variation / (Record no. 75626)

MARC details
000 -LEADER
fixed length control field 02135cam a2200337 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223032452.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 191203s2019 ua f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.13.07.M.Sc.2019.Ma.F
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Mahmoud Ismail Mehanna
245 10 - TITLE STATEMENT
Title False trips in gas power plant due to transient voltage variation /
Statement of responsibility, etc. Mahmoud Ismail Mehanna ; Supervised Essam Eldin M. Aboulzahab , Mahmoud Ibrahim Gilany
246 15 - VARYING FORM OF TITLE
Title proper/short title الفصل الخاطئ فى محطات التوليد الغازية نتيجة التذبذب اللحظى فى الجهد
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Mahmoud Ismail Mehanna ,
Date of publication, distribution, etc. 2019
300 ## - PHYSICAL DESCRIPTION
Extent 81 P. ;
Dimensions 30cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Engineering - Department of Electrical Power and Machines
520 ## - SUMMARY, ETC.
Summary, etc. The sudden isolation of a large combined cycle power plant in Alburullus, Kafr Elsheikh city, Egypt with a capacity of 4800 MW will lead to a defect in the electric grid stability. This sudden isolation occurs due to Trip important sensitive loads in the Gas station of this plant (Fuel gas compressors and auxiliary air compressor). This thesis presents some of the published researches for power conditioning devices used for compensating the voltage fluctuation problem. (DVR) was selected to monitor the source voltage of these sensitive loads and compare it with the reference voltage. If any voltage drop is detected, this value is injected into the load side. MATLAB/Simulink program is used to verify the effectiveness of this device in the compensation of the voltage sag with these loads in a duration less than 10msec. which is less than the trip setting of the load C.B
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Combined cycle
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Sensitive loads
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Unbalance
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Essam Eldin M. Aboulzahab ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Mahmoud Ibrahim Gilany ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Samia
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.13.07.M.Sc.2019.Ma.F 01010110080281000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.13.07.M.Sc.2019.Ma.F 01020110080281000 22.09.2023 CD - Rom 80281.CD