MARC details
000 -LEADER |
fixed length control field |
02389cam a2200325 a 4500 |
003 - CONTROL NUMBER IDENTIFIER |
control field |
EG-GiCUC |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
fixed length control field |
191221s2019 ua dh f m 000 0 eng d |
040 ## - CATALOGING SOURCE |
Original cataloging agency |
EG-GiCUC |
Language of cataloging |
eng |
Transcribing agency |
EG-GiCUC |
041 0# - LANGUAGE CODE |
Language code of text/sound track or separate title |
eng |
049 ## - LOCAL HOLDINGS (OCLC) |
Holding library |
Deposite |
097 ## - Thesis Degree |
Thesis Level |
M.Sc |
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) |
Classification number |
Cai01.13.04.M.Sc.2019.Ma.E |
100 0# - MAIN ENTRY--PERSONAL NAME |
Personal name |
Mahmoud Mohamed Metwally |
245 10 - TITLE STATEMENT |
Title |
Energy optimization for hydrocracker unit using hysys process simulation / |
Statement of responsibility, etc. |
Mahmoud Mohamed Metwally ; Supervised Mohamed Kamal Eldin , Ayat Ossama Ghallab , Mohamed Gamal Abdelnasser |
246 15 - VARYING FORM OF TITLE |
Title proper/short title |
ترشيد استخدام الطاقة في وحدة التكسير الهيدروچيني باستخدام برنامج الهايسيس للمحاكاة |
260 ## - PUBLICATION, DISTRIBUTION, ETC. |
Place of publication, distribution, etc. |
Cairo : |
Name of publisher, distributor, etc. |
Mahmoud Mohamed Metwally , |
Date of publication, distribution, etc. |
2019 |
300 ## - PHYSICAL DESCRIPTION |
Extent |
84 P. : |
Other physical details |
charts , facsimiles ; |
Dimensions |
30cm |
502 ## - DISSERTATION NOTE |
Dissertation note |
Thesis (M.Sc.) - Cairo University - Faculty of Engineering - Department of Chemical Engineering |
520 ## - SUMMARY, ETC. |
Summary, etc. |
The objective of this work is to demonstrate the importance of process simulation in the design and operation of the plants through assessing a case study based on an actual data from an existing Hydrocracking unit. There are two cases will be demonstrated first is that the plant is wasting about 6924 Nm3/h of hydrogen to be used as a fuel gas. Second is that the plant utilizing about 34.2*106 kcal/h as a duty in fired heater to preheat the fractionator feed from 248 {u00B0}C to 373 {u00B0}C. The steady state simulation tools will be used to study the changes to the process and how much energy can be conserved by applying few modifications, followed by cost estimation to evaluate the effectiveness and validation of the modifications. A comprehensive detailed steady state model for the whole plant was built using Aspen HYSYS. The results from the process simulation model was analyzed and it was found that about 6259 Nm3/h hydrogen with net present value of $4,008,833 and 9.6*106 kcal/h of heater duty can be conserved |
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE |
Additional physical form available note |
Issued also as CD |
653 #4 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
Chemical Engineering Plant Cost Index (CEPCI) |
653 #4 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
Hydrocracker unit |
653 #4 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
Process optimization |
700 0# - ADDED ENTRY--PERSONAL NAME |
Personal name |
Ayat Ossama Ghallab , |
Relator term |
|
700 0# - ADDED ENTRY--PERSONAL NAME |
Personal name |
Mohamed Gamal Abdelnasser , |
Relator term |
|
700 0# - ADDED ENTRY--PERSONAL NAME |
Personal name |
Mohamed Kamal Eldin , |
Relator term |
|
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) |
Cataloger |
Nazla |
Reviser |
Revisor |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) |
Cataloger |
Shimaa |
Reviser |
Cataloger |
942 ## - ADDED ENTRY ELEMENTS (KOHA) |
Source of classification or shelving scheme |
Dewey Decimal Classification |
Koha item type |
Thesis |