header

Energy optimization for hydrocracker unit using hysys process simulation / (Record no. 76048)

MARC details
000 -LEADER
fixed length control field 02389cam a2200325 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 191221s2019 ua dh f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.13.04.M.Sc.2019.Ma.E
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Mahmoud Mohamed Metwally
245 10 - TITLE STATEMENT
Title Energy optimization for hydrocracker unit using hysys process simulation /
Statement of responsibility, etc. Mahmoud Mohamed Metwally ; Supervised Mohamed Kamal Eldin , Ayat Ossama Ghallab , Mohamed Gamal Abdelnasser
246 15 - VARYING FORM OF TITLE
Title proper/short title ترشيد استخدام الطاقة في وحدة التكسير الهيدروچيني باستخدام برنامج الهايسيس للمحاكاة
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Mahmoud Mohamed Metwally ,
Date of publication, distribution, etc. 2019
300 ## - PHYSICAL DESCRIPTION
Extent 84 P. :
Other physical details charts , facsimiles ;
Dimensions 30cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Engineering - Department of Chemical Engineering
520 ## - SUMMARY, ETC.
Summary, etc. The objective of this work is to demonstrate the importance of process simulation in the design and operation of the plants through assessing a case study based on an actual data from an existing Hydrocracking unit. There are two cases will be demonstrated first is that the plant is wasting about 6924 Nm3/h of hydrogen to be used as a fuel gas. Second is that the plant utilizing about 34.2*106 kcal/h as a duty in fired heater to preheat the fractionator feed from 248 {u00B0}C to 373 {u00B0}C. The steady state simulation tools will be used to study the changes to the process and how much energy can be conserved by applying few modifications, followed by cost estimation to evaluate the effectiveness and validation of the modifications. A comprehensive detailed steady state model for the whole plant was built using Aspen HYSYS. The results from the process simulation model was analyzed and it was found that about 6259 Nm3/h hydrogen with net present value of $4,008,833 and 9.6*106 kcal/h of heater duty can be conserved
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Chemical Engineering Plant Cost Index (CEPCI)
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Hydrocracker unit
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Process optimization
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Ayat Ossama Ghallab ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Mohamed Gamal Abdelnasser ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Mohamed Kamal Eldin ,
Relator term
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Shimaa
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.13.04.M.Sc.2019.Ma.E 01010110080459000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.13.04.M.Sc.2019.Ma.E 01020110080459000 22.09.2023 CD - Rom 80459.CD