Evaluation of implant stability after application of platelet rich fibrin in mandibular posterior ridge splitting and immediate implant placement versus xenograft application : (Record no. 76279)
[ view plain ]
000 -LEADER | |
---|---|
fixed length control field | 02905cam a2200337 a 4500 |
003 - CONTROL NUMBER IDENTIFIER | |
control field | EG-GiCUC |
005 - DATE AND TIME OF LATEST TRANSACTION | |
control field | 20250223032512.0 |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
fixed length control field | 200111s2019 ua dho f m 000 0 eng d |
040 ## - CATALOGING SOURCE | |
Original cataloging agency | EG-GiCUC |
Language of cataloging | eng |
Transcribing agency | EG-GiCUC |
041 0# - LANGUAGE CODE | |
Language code of text/sound track or separate title | eng |
049 ## - LOCAL HOLDINGS (OCLC) | |
Holding library | Deposite |
097 ## - Thesis Degree | |
Thesis Level | Ph.D |
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) | |
Classification number | Cai01.09.13.Ph.D.2019.Sh.E |
100 0# - MAIN ENTRY--PERSONAL NAME | |
Personal name | Shymaa Maghawry Ibrahim |
245 10 - TITLE STATEMENT | |
Title | Evaluation of implant stability after application of platelet rich fibrin in mandibular posterior ridge splitting and immediate implant placement versus xenograft application : |
Remainder of title | Randomized clinical trial / |
Statement of responsibility, etc. | Shymaa Maghawry Ibrahim ; Supervised Elzahraa Fatma Elbagoury , Tarek Elghareeb |
246 15 - VARYING FORM OF TITLE | |
Title proper/short title | تقييم ثبات الغرسة بعد استعمال الفيبرين الغنى بالصفائح الدموية فى تقسيم الحافة السنخية للفك السفلى مع الوضع الفورى للغرسة مقابل استعمال رقعة عظمية حيوانية المصدر : |
Remainder of title | تجربة اكلينيكية عشوائية |
260 ## - PUBLICATION, DISTRIBUTION, ETC. | |
Place of publication, distribution, etc. | Cairo : |
Name of publisher, distributor, etc. | Shymaa Maghawry Ibrahim , |
Date of publication, distribution, etc. | 2019 |
300 ## - PHYSICAL DESCRIPTION | |
Extent | 117 P. : |
Other physical details | charts , facsimiles , photoghraphs ; |
Dimensions | 25cm |
502 ## - DISSERTATION NOTE | |
Dissertation note | Thesis (Ph.D.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Oral and Maxillofacial Surgery |
520 ## - SUMMARY, ETC. | |
Summary, etc. | Aim of the Study: The purpose of this study aimed to answer a clinical question whether the use of platelet rich fibrin after ridge splitting with simultaneous implant placement will enhance implant stability in comparison with xenograft or not. Materials and Methods: Sixteen patients were divided into 2 equal groups (Group I & Group II). Patients in both groups underwent surgical ridge splitting for narrow edentulous posterior mandibular ridge with simultaneous implant placement. In Group I, platelet rich fibrin used as a graft material around the implant in between buccal and lingual cortices. In Group II, Tutogen ® xenograft used as a graft material around the implant in between buccal and lingual cortices. Each patient was assessed for implant stability and relative bone density around the implant. Implant stability measured by Osstell TM by means of resonance frequency analysis (RFA) which was recoded as Implant Stability Quotient (ISQ) values first intraoperative then at intervals 3 months, 6months and 9 months postoperatively. However, the relative bone density has been evaluated by cone beam computed tomography (CBCT) immediate post-operative and 6 months later. All results were statistically analyzed |
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE | |
Additional physical form available note | Issued also as CD |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Alveolar ridge splitting |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Platelet rich fibrin |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Xenograft |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Elzahraa Fatma Elbagoury , |
Relator term | |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Tarek Elghareeb , |
Relator term | |
856 ## - ELECTRONIC LOCATION AND ACCESS | |
Uniform Resource Identifier | <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a> |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) | |
Cataloger | Nazla |
Reviser | Revisor |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) | |
Cataloger | Shimaa |
Reviser | Cataloger |
942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
Source of classification or shelving scheme | Dewey Decimal Classification |
Koha item type | Thesis |
Source of classification or shelving scheme | Not for loan | Home library | Current library | Date acquired | Full call number | Barcode | Date last seen | Koha item type | Copy number |
---|---|---|---|---|---|---|---|---|---|
Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | قاعة الرسائل الجامعية - الدور الاول | 11.02.2024 | Cai01.09.13.Ph.D.2019.Sh.E | 01010110080614000 | 22.09.2023 | Thesis | ||
Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | مخـــزن الرســائل الجـــامعية - البدروم | 11.02.2024 | Cai01.09.13.Ph.D.2019.Sh.E | 01020110080614000 | 22.09.2023 | CD - Rom | 80614.CD |