header

Evaluation of implant stability after application of platelet rich fibrin in mandibular posterior ridge splitting and immediate implant placement versus xenograft application : (Record no. 76279)

MARC details
000 -LEADER
fixed length control field 02905cam a2200337 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223032512.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 200111s2019 ua dho f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level Ph.D
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.09.13.Ph.D.2019.Sh.E
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Shymaa Maghawry Ibrahim
245 10 - TITLE STATEMENT
Title Evaluation of implant stability after application of platelet rich fibrin in mandibular posterior ridge splitting and immediate implant placement versus xenograft application :
Remainder of title Randomized clinical trial /
Statement of responsibility, etc. Shymaa Maghawry Ibrahim ; Supervised Elzahraa Fatma Elbagoury , Tarek Elghareeb
246 15 - VARYING FORM OF TITLE
Title proper/short title تقييم ثبات الغرسة بعد استعمال الفيبرين الغنى بالصفائح الدموية فى تقسيم الحافة السنخية للفك السفلى مع الوضع الفورى للغرسة مقابل استعمال رقعة عظمية حيوانية المصدر :
Remainder of title تجربة اكلينيكية عشوائية
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Shymaa Maghawry Ibrahim ,
Date of publication, distribution, etc. 2019
300 ## - PHYSICAL DESCRIPTION
Extent 117 P. :
Other physical details charts , facsimiles , photoghraphs ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (Ph.D.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Oral and Maxillofacial Surgery
520 ## - SUMMARY, ETC.
Summary, etc. Aim of the Study: The purpose of this study aimed to answer a clinical question whether the use of platelet rich fibrin after ridge splitting with simultaneous implant placement will enhance implant stability in comparison with xenograft or not. Materials and Methods: Sixteen patients were divided into 2 equal groups (Group I & Group II). Patients in both groups underwent surgical ridge splitting for narrow edentulous posterior mandibular ridge with simultaneous implant placement. In Group I, platelet rich fibrin used as a graft material around the implant in between buccal and lingual cortices. In Group II, Tutogen ® xenograft used as a graft material around the implant in between buccal and lingual cortices. Each patient was assessed for implant stability and relative bone density around the implant. Implant stability measured by Osstell TM by means of resonance frequency analysis (RFA) which was recoded as Implant Stability Quotient (ISQ) values first intraoperative then at intervals 3 months, 6months and 9 months postoperatively. However, the relative bone density has been evaluated by cone beam computed tomography (CBCT) immediate post-operative and 6 months later. All results were statistically analyzed
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Alveolar ridge splitting
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Platelet rich fibrin
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Xenograft
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Elzahraa Fatma Elbagoury ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Tarek Elghareeb ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Shimaa
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.09.13.Ph.D.2019.Sh.E 01010110080614000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.09.13.Ph.D.2019.Sh.E 01020110080614000 22.09.2023 CD - Rom 80614.CD