header

Clinical evaluation of the effect of low speed drilling versus conventional drilling technique on crestal bone level in maxilla : (Record no. 76301)

MARC details
000 -LEADER
fixed length control field 02871cam a2200337 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223032513.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 200112s2019 ua dh f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.09.09.M.Sc.2019.Is.C
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Islam Atef Mohamed Abdelrazik Kandil
245 10 - TITLE STATEMENT
Title Clinical evaluation of the effect of low speed drilling versus conventional drilling technique on crestal bone level in maxilla :
Remainder of title A randomized controlled clinical trial /
Statement of responsibility, etc. Islam Atef Mohamed Abdelrazik Kandil ; Supervised Hani Mahmoud Essam Elnahass , Karim Mohamed Fawzy Elsayed
246 15 - VARYING FORM OF TITLE
Title proper/short title مستوى على التقليدية الحفر تقنية مقابل الحفر سرعة انخفاض للتأثير السريرى التقييم العلوى الفك فى القشرى العظم
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Islam Atef Mohamed Abdelrazik Kandil ,
Date of publication, distribution, etc. 2019
300 ## - PHYSICAL DESCRIPTION
Extent 108 P. :
Other physical details charts , facsimiles ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontics
520 ## - SUMMARY, ETC.
Summary, etc. Aim: The aim of the present study was to evaluate the efficiency of low versus conventional speed drilling regarding the amount of crestal bone loss, bone density values, implant survival, implant stability, Visual Analogue Scale score and patients{u2019} satisfaction over 6 months follow up, following implant placement in maxillary edentulous ridge. Materials and methods: The present study is a randomized clinical trial conducted on 12 patients to evaluate the amount of crestal bone loss , density values, implant survival ,implant stability ,VAS score and patient satisfaction over 6 months follow up, following implant placement in maxillary edentulous ridge at low speed drilling without irrigation versus conventional drilling speed technique.Classical implant placement without any bone augmentation was the technique used in both groups. All patients were followed up clinically and radiographically for 6 months. Radiographic evaluation involved digital radiograph immediately after implant insertion, three months and six months postoperatively to evaluate crestal bone loss and bone density changes. Resonance frequency analysis to measure implant stability using Osstell device was performed immediately after implant insertion, three months postoperative at time of implant exposure and six months postoperative
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Conventional speed drilling
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Dental implant
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Low speed drilling
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Hani Mahmoud Essam Elnahass ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Karim Mohamed Fawzy Elsayed ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Shimaa
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.09.09.M.Sc.2019.Is.C 01010110080622000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.09.09.M.Sc.2019.Is.C 01020110080622000 22.09.2023 CD - Rom 80622.CD