header

Radiographic evaluation of bone and mucosa in an edentulous area before implant placement using low dose CBCT with radiopaque X-resin stent versus CT & ridge mapping : (Record no. 76748)

MARC details
000 -LEADER
fixed length control field 03045cam a2200325 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 200223s2019 ua dh f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level Ph.D
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.09.05.Ph.D.2019.Na.R
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Nader Nabil Fouad
245 10 - TITLE STATEMENT
Title Radiographic evaluation of bone and mucosa in an edentulous area before implant placement using low dose CBCT with radiopaque X-resin stent versus CT & ridge mapping :
Remainder of title Diagnostic accuracy study /
Statement of responsibility, etc. Nader Nabil Fouad ; Supervised Mushira Mohamed Dahaba , Eman Abdelaziz Ahmed , Injy Ahmed Mahmoud
246 15 - VARYING FORM OF TITLE
Title proper/short title أستخدام الأشعة المقطعية بالحاسوب مخروطية الشعاع منخفض الجرعة الأشعاعية مع قالب ظليل للأشعة مقابل الأشعة المقطعية بالحاسوب وموضعه الحرف في التقييم الإشعاعي للعظم والأنسجة المخاطية في منطقة عديمة الأسنان قبل وضع الغرسات
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Nader Nabil Fouad ,
Date of publication, distribution, etc. 2019
300 ## - PHYSICAL DESCRIPTION
Extent 139 P. :
Other physical details charts , facsimiles ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (Ph.D.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Oral (Radiology and Diagnosis)
520 ## - SUMMARY, ETC.
Summary, etc. Several factors are known to affect success of any implant system. These factors may be related to features locally, such as bone quality and quantity. Other factors are related to the surgical method by which an implant is placed, or which are related to the implant system used. The purpose of this study was to evaluate bone and soft tissue mucosa of the jaws using CBCT with radiopaque material to assess their clinical significance versus CT and ridge mapping prior to implant placement. Twenty patients undergoing implant surgeries for edentulous areas (mandible and maxilla) were included in this study. All participants were selected randomly from patients submitted as emergency cases to the outpatient clinics of Cairo University, Faculty of Dentistry and University Hospital of Misr University for Science and Technology. All patients were of both sexes and their ages ranged between 25-50 years with a mean age of 35 years. Ninety-six edentulous sites were chosen from the twenty patients and each site was subjected to three different types of examination namely; ridge mapping examination, CBCT examination with the X-resin stent and CT examination. All measurements were statistically analyzed to reveal the most and accurate tool in assessing soft and bone tissues in comparison to the gold standard modality (CT)
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Bone (B)
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Computed Tomography (CT)
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Cone Beam Computed Tomography (CBCT)
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Eman Abdelaziz Ahmed ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Injy Ahmed Mahmoud ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Mushira Mohamed Dahaba ,
Relator term
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Shimaa
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.09.05.Ph.D.2019.Na.R 01010110080882000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.09.05.Ph.D.2019.Na.R 01020110080882000 22.09.2023 CD - Rom 80882.CD