header

Postoperative hypersensitivity and digital radiographic assessment of a zinc modified versus a conventional glass ionomer cement in deep carious lesion : (Record no. 76820)

MARC details
000 -LEADER
fixed length control field 03241cam a2200337 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223032529.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 200229s2019 ua dh f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level Ph.D
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.09.03.Ph.D.2019.Di.P
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Dina Mounir Elkady
245 10 - TITLE STATEMENT
Title Postoperative hypersensitivity and digital radiographic assessment of a zinc modified versus a conventional glass ionomer cement in deep carious lesion :
Remainder of title Randomized controlled clinical trial /
Statement of responsibility, etc. Dina Mounir Elkady ; Supervied Mohamed Riad Farid , Rasha Raafat Hassan
246 15 - VARYING FORM OF TITLE
Title proper/short title فرط الحساسية والتقييم الإشعاعى الرقمى لاسمنت الزجاجى المعدل بالزنك واالسمنت الزجاجى التقليدى على الآفة النخاع العميق :
Remainder of title تجربة عشوائية مظبوطة
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Dina Mounir Elkady ,
Date of publication, distribution, etc. 2019
300 ## - PHYSICAL DESCRIPTION
Extent 74 P. :
Other physical details charts , facsimiles ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (Ph.D.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Operative Dentistry
520 ## - SUMMARY, ETC.
Summary, etc. This study aims to determine the effect of different glass ionomer in the healing of deep carious lesion after partial caries removal. A total of 50 teeth of patients who fulfilled the inclusion criteria were selected to participate in the study. Then they were divided into two main groups: control group and intervention group. Teeth with deep caries undergone caries removal with hand or rotary instrument after rubber dame isolation, the caries was removed selectively to firm dentin using the partial caries removal technique and the tested materials were placed in the final restoration.The control group receive a high viscosity glass ionomer(Equia fill) and intervention group receive a zinc modified glass ionomer(Chemfill rock). Postoperative hypersensitivity (using thermal test and percussion test) and periapical lesions (using digital periapical radiograph) were tested in this period at the baseline (T0), after three months (T3) and after six months (T6). After following up period only 48 teeth were statistically analyzed Results showed that both materials have the same effect postoperatively on the pulpal tissues confirmed with thermal, percussion tests and with digital radiograph. We concluded that under the limitation of this study: 1.Glass ionomer either conventional or zinc modified could be successfully used as restoration with partial caries removal technique. 2.zinc modified glass ionomer lessen the postoperative hypersensitivity associated with partial caries removal. 3.Partial caries removal technique could preserve pulp vitality.Clinical recommendation: Further studies to assess the clinical behavior of material is needed for more long time of assessment
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Deep carious lesion
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Digital radiographic
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Postoperative hypersensitivity
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Mohamed Riad Farid ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Rasha Raafat Hassan ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Shimaa
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.09.03.Ph.D.2019.Di.P 01010110080909000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.09.03.Ph.D.2019.Di.P 01020110080909000 22.09.2023 CD - Rom 80909.CD