header

Clinical evaluation of stability of short implant versus standard implants placed with internal sinus floor elevation in edentulous posterior maxilla : (Record no. 76880)

MARC details
000 -LEADER
fixed length control field 03252cam a2200337 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223032531.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 200308s2018 ua do f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.09.08.M.Sc.2018.Mo.C
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Mostafa Magdy Awad Mostafa
245 10 - TITLE STATEMENT
Title Clinical evaluation of stability of short implant versus standard implants placed with internal sinus floor elevation in edentulous posterior maxilla :
Remainder of title A randomized controlled clinical trial : (part 2) /
Statement of responsibility, etc. Mostafa Magdy Awad Mostafa ; Supervised Mona Shoeib , Hani Elnahass
246 15 - VARYING FORM OF TITLE
Title proper/short title التقييم السريرى لاستقرار غرس قصير بالمقارنة لغرس معيار قياسى وضع مع رفع لطابق الجيب الانفى فى فك علوى خلفى عديم الاسنان :
Remainder of title تجربة مسيطرة إكلينيكية عشوائية : الجزء الثانى
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Mostafa Magdy Awad Mostafa ,
Date of publication, distribution, etc. 2018
300 ## - PHYSICAL DESCRIPTION
Extent 132 P. :
Other physical details charts , photographs ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Periodontology
520 ## - SUMMARY, ETC.
Summary, etc. Objective: The aim of this study is to clinically evaluate the stability of short implants (5.5mm) versus standard implant (10mm) placed with osteotome sinus floor elevation in patients with edentulous posterior maxilla. Materials and Methods: The purpose of this study is to clinically evaluate the stability of short implants (5.5mm) versus standard implants (10mm) placed with osteotome sinus floor elevation technique in medically free patients. This study included 16 implants placed in 16 patients. With 8 implants in every group. Results: Pain and swelling were measured 12 and 8 days respectively after dental implant placement. Recession, probing depth, bleeding and plaque indices were recorded 4 months and 12 months after the day of implant placement. Conclusion: After analysis of the data of this present study, we can conclude the following: The two implant placement protocols showed comparable implant stability quotient (ISQ) and implant success. In terms of crestal bone loss, no statistically significant difference was found between both groups initially, 6 and 12 month followup. Except after 4 months, a significantly higher mean crestal bone loss was recorded in long implants with sinus lift Higher results of post-operative pain and swelling (12 and 8 days respectively) were evident in the control group (standard implant with osteotome sinus floor elevation) than the intervention group (short implant 5.5mm). but found to be statistically insignificant PPD, and MPI showed no statistically significant difference between both groups. MBI showed a significant higher values in long implants after 4 months (p=0.006) than short implants
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Internal Sinus Floor
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Short Implant versus
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Standard Implants
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Hani Elnahass ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Mona Shoeib ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Asmaa
Reviser Cataloger
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.09.08.M.Sc.2018.Mo.C 01010110080959000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.09.08.M.Sc.2018.Mo.C 01020110080959000 22.09.2023 CD - Rom 80959.CD