header

Assessment the photo-neutron contamination of IMRT and 3D-conformal techniques using Experimental measurements and Monte Carlo simulations / (Record no. 77445)

MARC details
000 -LEADER
fixed length control field 03210cam a2200349 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223032549.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 200829s2019 ua dh f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level Ph.D
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.12.04.Ph.D.2019.Eb.A
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Ebtesam Mohamed Mohamedy
245 10 - TITLE STATEMENT
Title Assessment the photo-neutron contamination of IMRT and 3D-conformal techniques using Experimental measurements and Monte Carlo simulations /
Statement of responsibility, etc. Ebtesam Mohamed Mohamedy ; Supervised Wafaa Mohamed Khalil , Nadia Lotfy Helal , Ehab Marouf Attalla
246 15 - VARYING FORM OF TITLE
Title proper/short title تقييم التلوث النيوترونى لتقنيات العلاج متغير الشده وثلاثى الأبعاد باستخدام نموذج للمحاكاة والتأكد التجريبى
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Ebtesam Mohamed Mohamedy ,
Date of publication, distribution, etc. 2019
300 ## - PHYSICAL DESCRIPTION
Extent 74 , (10) P. :
Other physical details charts , facsimiles ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (Ph.D.) - Cairo University - Faculty of Science - Department of Biophysics
520 ## - SUMMARY, ETC.
Summary, etc. The aim of the study is to evaluate the dependence of photo-neutron production on different variables and different treatment methods (IMRT and 3DCRT techniques) using TLD (600/700) and MC simulation. The equivalent neutron doses were measured at different field sizes, depth in phantom, gantry angles and different distances along patient couch. The equivalent neutron doses were measured for 5 Prostate cancer cases using TLD (600/700).The equivalent neutron doses were measured for selected rectum case using TLD (600/700) and Geant 4 simulation. The results showed that: The measured equivalent neutron doses decreases from0.2 mSv/Gy to0.09 mSv/Gy as increases field sizes from 2x2 cm2 to 20x20 cm2. The measured equivalent neutron doses was maximum (0.15 mSv/Gy) at dmax =5 cm and decreases gradually as increases depth in phantom reaches to 0.07 mSv/Gy at 10 cm. The measured equivalent neutron doses decreases from 1.5mSv/Gy to0.02 mSv/Gy when measured at isocenter and at 100cm along the patient couch. Using 3DCRT for PTV and OARs were ranging from 0.027 to 0.39 mSv per photon Gy and for IMRT were 0.135 to 2.34 mSv per photon Gy. The measured equivalent neutron doses for rectum case were ranging from 0.04 to 0.24mSv per photon Gy, this result nearly the same calculated by MC. In conclusion the photo-neutron production is decreases as increases field size and distance from isocenter along patient couch while increases with depth in phantom up to dmax and decreases gradually as increases depth in phantom. IMRT requires longer beam-on time than 3DCRT leading to worse OARs sparing and increase the production of photo-neutrons than 3DCRT
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Intensity Modulated Radiation Therapy (IMRT )
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term The equivalent neutron doses
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Three-dimensional conformal radio therapy (3DCRT )
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Ehab Marouf Attalla ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Nadia Lotfy Helal ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Wafaa Mohamed Khalil ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Shimaa
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.12.04.Ph.D.2019.Eb.A 01010110081352000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.12.04.Ph.D.2019.Eb.A 01020110081352000 22.09.2023 CD - Rom 81352.CD