Automatic monitoring of the medical equipment performance using electrical signature analysis / (Record no. 78539)
[ view plain ]
000 -LEADER | |
---|---|
fixed length control field | 03100cam a2200349 a 4500 |
003 - CONTROL NUMBER IDENTIFIER | |
control field | EG-GiCUC |
005 - DATE AND TIME OF LATEST TRANSACTION | |
control field | 20250223032623.0 |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
fixed length control field | 201103s2020 ua dh f m 000 0 eng d |
040 ## - CATALOGING SOURCE | |
Original cataloging agency | EG-GiCUC |
Language of cataloging | eng |
Transcribing agency | EG-GiCUC |
041 0# - LANGUAGE CODE | |
Language code of text/sound track or separate title | eng |
049 ## - LOCAL HOLDINGS (OCLC) | |
Holding library | Deposite |
097 ## - Thesis Degree | |
Thesis Level | Ph.D |
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) | |
Classification number | Cai01.13.03.Ph.D.2020.Es.A |
100 0# - MAIN ENTRY--PERSONAL NAME | |
Personal name | Essam Eldeen Naguib Mohammed Tawfik |
245 10 - TITLE STATEMENT | |
Title | Automatic monitoring of the medical equipment performance using electrical signature analysis / |
Statement of responsibility, etc. | Essam Eldeen Naguib Mohammed Tawfik ; Supervised Ahmed H. Kandil , Ahmed M . Elbialy , Sahar Fawzi |
246 15 - VARYING FORM OF TITLE | |
Title proper/short title | الرصد التلقائى لأداء المعدات الطبية باستخدام تحليل التوقيعات الكهربائية |
260 ## - PUBLICATION, DISTRIBUTION, ETC. | |
Place of publication, distribution, etc. | Cairo : |
Name of publisher, distributor, etc. | Essam Eldeen Naguib Mohammed Tawfik , |
Date of publication, distribution, etc. | 2020 |
300 ## - PHYSICAL DESCRIPTION | |
Extent | 84 P . : |
Other physical details | charts , facsmilies ; |
Dimensions | 30cm |
502 ## - DISSERTATION NOTE | |
Dissertation note | Thesis (Ph.D.) - Cairo University - Faculty of Engineering - Department of Systems and Biomedical Engineering |
520 ## - SUMMARY, ETC. | |
Summary, etc. | Quantitative measurement of the effective usability of the medical equipment is an important parameter in the quality and performance assessment. This work introduces a simple non-invasive technique for real time monitoring of medical equipment modes of operation based on its power consumption pattern. Mode of operation detection is a needed to specify the medical equipment reliability, availability, maintainability and usability. The Electrical Signature Analysis technique (ESA), is applied to monitor the overall electric current consumption of the electromechanical and power components inside the medical equipment. ESA is an extracted using the Root Mean Square (RMS) of the electric current measured by a meter interfaced to a PC via its USB port. The ESA of the medial equipment is a recorded, analyzed and correlated with the stored electric current consumption patterns of each specific mode of operation. The results were promising to accomplish the medical equipment monitoring application. This thesis presents an automatic fault detection system to increase reliability and efficient use of medical equipment. The system is an implemented based on an embedded circuit that uses real-time, external and non-invasive electric current sensor to apply Electrical Current Signature Analysis (ECSA). The Root Mean Square (RMS) of the collected data were calculated, saved and analyzed. The system has been a tested for two different models of medical equipment. Promising results were an obtained from testing two types of laboratory equipment. The system was able to detect the occurrence of different faults during equipment use in several modes of operation |
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE | |
Additional physical form available note | Issued also as CD |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Asset management |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Clinical engineering |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Medical equipment monitoring |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Ahmed H. Kandil , |
Relator term | |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Ahmed M . Elbialy , |
Relator term | |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Sahar Fawzi , |
Relator term | |
856 ## - ELECTRONIC LOCATION AND ACCESS | |
Uniform Resource Identifier | <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a> |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) | |
Cataloger | Amira |
Reviser | Cataloger |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) | |
Cataloger | Nazla |
Reviser | Revisor |
942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
Source of classification or shelving scheme | Dewey Decimal Classification |
Koha item type | Thesis |
Source of classification or shelving scheme | Not for loan | Home library | Current library | Date acquired | Full call number | Barcode | Date last seen | Koha item type | Copy number |
---|---|---|---|---|---|---|---|---|---|
Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | قاعة الرسائل الجامعية - الدور الاول | 11.02.2024 | Cai01.13.03.Ph.D.2020.Es.A | 01010110081923000 | 22.09.2023 | Thesis | ||
Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | مخـــزن الرســائل الجـــامعية - البدروم | 11.02.2024 | Cai01.13.03.Ph.D.2020.Es.A | 01020110081923000 | 22.09.2023 | CD - Rom | 81923.CD |