header

Influence of implant thread{u2019}s cross-sectional design on the micromotion of the implants in different bone qualities : (Record no. 79061)

MARC details
000 -LEADER
fixed length control field 02882cam a2200337 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223032639.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 201203s2020 ua dh f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.09.09.M.Sc.2020.Da.I
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Dalia Samir Mahmoud Shaker
245 10 - TITLE STATEMENT
Title Influence of implant thread{u2019}s cross-sectional design on the micromotion of the implants in different bone qualities :
Remainder of title Finite element analysis /
Statement of responsibility, etc. Dalia Samir Mahmoud Shaker ; Supervised Amr Hosny Elkhadem , Mohammed Atef Abdelrasoul
246 15 - VARYING FORM OF TITLE
Title proper/short title طريقة تحليل العناصر الغير المحدودة :
Remainder of title تأثير تصميم المقطع العرضى لسن لولب الغرسات على الحركات الدقيقة للغرسات فى العظام مختلفة الجودة
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Dalia Samir Mahmoud Shaker ,
Date of publication, distribution, etc. 2020
300 ## - PHYSICAL DESCRIPTION
Extent 119 P . :
Other physical details charts , facsmilies ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontics
520 ## - SUMMARY, ETC.
Summary, etc. Implant micromotion can be one of the causes of implant failure. One of the factors affecting micromotion is the implant macrodesign, which includes the implant{u2019}s thread cross sectional design. The aim of this study was to evaluate the effect of the implant{u2019}s thread cross sectional design on the micromotion of the implants in different bone qualities. In this finite element analysis study, four implant models exhibiting four different thread designs (buttress, reverse buttress, v-shaped and square) were created using Solidworks software. Each model was assembled with a superstructure in four models of four different bone qualities resulting in 16 groups. Each group was examined for micromotion under 100N force using ANSYS software. The results revealed that when comparing micromotion in different bone qualities, the lowest micromotion values were observed with D1 bone and the highest values were observed with D4 bone regardless the thread design. When comparing different thread designs, in D1 and D2 bone, the lowest micromotion was observed with v-shaped thread, which was lower than the square thread and the buttress thread was lower than the reverse buttress thread. While in D3 and D4 bone, the lowest micromotion was observed with the square thread, which was lower than the v-shaped and the reverse buttress thread was lower than the buttress thread
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Finite element analysis
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Micromotion
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Thread design
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Amr Hosny Elkhadem ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Mohammed Atef Abdelrasoul ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Amira
Reviser Cataloger
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.09.09.M.Sc.2020.Da.I 01010110082234000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.09.09.M.Sc.2020.Da.I 01020110082234000 22.09.2023 CD - Rom 82234.CD