MARC details
000 -LEADER |
fixed length control field |
02699cam a2200325 a 4500 |
003 - CONTROL NUMBER IDENTIFIER |
control field |
EG-GiCUC |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
fixed length control field |
201220s2020 ua dh f m 000 0 eng d |
040 ## - CATALOGING SOURCE |
Original cataloging agency |
EG-GiCUC |
Language of cataloging |
eng |
Transcribing agency |
EG-GiCUC |
041 0# - LANGUAGE CODE |
Language code of text/sound track or separate title |
eng |
049 ## - LOCAL HOLDINGS (OCLC) |
Holding library |
Deposite |
097 ## - Thesis Degree |
Thesis Level |
M.Sc |
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) |
Classification number |
Cai01.11.28.M.Sc.2020.Lo.V |
100 0# - MAIN ENTRY--PERSONAL NAME |
Personal name |
Lobna Fath Allah Elgammal |
245 10 - TITLE STATEMENT |
Title |
Value of lung ultrasound in Neonatal Cardiac Intensive Care Unit, Children Hospital Cairo University / |
Statement of responsibility, etc. |
Lobna Fath Allah Elgammal ; Supervised Amal Mahmoud Elsisi , Maha Fathy Sheba , Mohammed Mosad Mahmoud |
246 15 - VARYING FORM OF TITLE |
Title proper/short title |
قيمة استخدام الموجات الصوتية على الرئة بالرعاية القلبية لحديثى الولادة.مستشفى الأطفال جامعة القاهرة |
260 ## - PUBLICATION, DISTRIBUTION, ETC. |
Place of publication, distribution, etc. |
Cairo : |
Name of publisher, distributor, etc. |
Lobna Fath Allah Elgammal , |
Date of publication, distribution, etc. |
2020 |
300 ## - PHYSICAL DESCRIPTION |
Extent |
140 P. : |
Other physical details |
charts , facsmilies ; |
Dimensions |
25cm |
502 ## - DISSERTATION NOTE |
Dissertation note |
Thesis (M.Sc.) - Cairo University - Faculty of Medicine - Department of Pediatrics |
520 ## - SUMMARY, ETC. |
Summary, etc. |
Purpose: The aim of this cross-sectional study was to assess lung ultrasonography as an alternative diagnostic tool to bedside Chest X-ray for the diagnosis of different neonatal chest diseases. Patients & methods: The study was performed on 60 neonates with congenital heart diseases admitted during the period from February 2019 to October 2019 in the NICU and Neonatal Cardiac Intensive Care Unit of Cairo University Pediatric Hospital presenting with clinical picture of respiratory distress. Chest X-rays and lung US were done. Results: We found that LUS has higher accuracy at diagnosis of pleural effusion. In pneumothorax group, equivocal results by both Chest X-ray and lung ultrasound, so it can be used as an alternative to Chest X-ray. While in RDS, there was mild discrepancy, Chest X-ray could detect one case that couldn{u2019}t be detected by LUS. Also, in pneumonia, there was mild discrepancy, LUS couldn{u2019}t detect 2 cases but they were detected by Chest X-ray. As it is mild discrepancy, we can use lung ultrasound as a diagnosti tool at this group. Conclusion: Lung ultrasound is a simple and reliable tool that can be used by the clinician in different neonatal chest diseases. It is as reliable as CXR, can be easily repeated at the patient's bedside and carries no risk of ionizing radiation, in contrast to radiography and CT imaging |
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE |
Additional physical form available note |
Issued also as CD |
653 #4 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
Chest |
653 #4 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
Chest radiography |
653 #4 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
Neonates |
700 0# - ADDED ENTRY--PERSONAL NAME |
Personal name |
Amal Mahmoud Elsisi , |
Relator term |
|
700 0# - ADDED ENTRY--PERSONAL NAME |
Personal name |
Maha Fathy Sheba , |
Relator term |
|
700 0# - ADDED ENTRY--PERSONAL NAME |
Personal name |
Mohammed Mosad Mahmoud , |
Relator term |
|
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) |
Cataloger |
Amira |
Reviser |
Cataloger |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) |
Cataloger |
Nazla |
Reviser |
Revisor |
942 ## - ADDED ENTRY ELEMENTS (KOHA) |
Source of classification or shelving scheme |
Dewey Decimal Classification |
Koha item type |
Thesis |