header

Assessment of the central venous pressure via ultrasonography of the internal jugular vein in hemodialysis patients / (Record no. 79736)

MARC details
000 -LEADER
fixed length control field 03100cam a2200349 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223032700.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 210130s2020 ua dh f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.11.31.M.Sc.2020.Am.A
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Amr Abdulrahim Said Ibrahim
245 10 - TITLE STATEMENT
Title Assessment of the central venous pressure via ultrasonography of the internal jugular vein in hemodialysis patients /
Statement of responsibility, etc. Amr Abdulrahim Said Ibrahim ; Supervised Aboelmagd Albohy , Ahmed Abdalrahman Baz , Hussein Saeed Hussein Elfishawy
246 15 - VARYING FORM OF TITLE
Title proper/short title تقدير ضغط الدم الوريدى المركزى بالموجات فوق الصوتية على الوريد الودجى الداخلى فى مرضى غسيل الكلى
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Amr Abdulrahim Said Ibrahim ,
Date of publication, distribution, etc. 2020
300 ## - PHYSICAL DESCRIPTION
Extent 90 P. :
Other physical details charts , facimiles ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Medicine - Department of Radio - Diagnosis
520 ## - SUMMARY, ETC.
Summary, etc. Introduction: Central venous pressure is among the most widely used parameters to assess for hydration status in renal dialysis patients and guiding fluid therapy. However, assessment of CVP via insertion of a central venous catheter is an invasive procedure which carries variable risks. The aim of the work: To investigate the accuracy of CVP measured by ultrasonography of the internal jugular vein in hemodialysis patients in comparison with CVP measured via central venous catheter. Materials and methods: The current study included one hundred and six patients. All patients were subjected to assessment of CVP through the already applied central venous catheters as well as by high resolution ultrasound of the internal jugular vein.Two ultrasonographic methods were used, in method 1 the vertical height between collapsing point of IJV and sternal angle was measured then 5 cmH20 were added, while in method 2 the calculation of IJV/CCA cross-sectional area ratio was done. Results: A highly significant positive correlation was found between both method1 and method 2 and the invasive CVP measurement through central venous catheter(CVPi), while there was no significant correlation was found between patient sex, presence of DM, presence of HTN or the examined side, and between CVPi. Conclusion: Ultrasonography of the internal jugular vein appears to be a simple, cheap, reliable and non-invasive technique which could be used for repeated monitoring of the central venous pressure even in the patients dialyzed using an arteriovenous fistula and consequently do not have a central venous line available
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Central venous pressure
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Internal jugular vein
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Ultrasonography
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Aboelmagd Albohy ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Ahmed Abdalrahman Baz ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Hussein Saeed Hussein Elfishawy ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Shimaa
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.11.31.M.Sc.2020.Am.A 01010110082655000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.11.31.M.Sc.2020.Am.A 01020110082655000 22.09.2023 CD - Rom 82655.CD