Assessment of the central venous pressure via ultrasonography of the internal jugular vein in hemodialysis patients / (Record no. 79736)
[ view plain ]
000 -LEADER | |
---|---|
fixed length control field | 03100cam a2200349 a 4500 |
003 - CONTROL NUMBER IDENTIFIER | |
control field | EG-GiCUC |
005 - DATE AND TIME OF LATEST TRANSACTION | |
control field | 20250223032700.0 |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
fixed length control field | 210130s2020 ua dh f m 000 0 eng d |
040 ## - CATALOGING SOURCE | |
Original cataloging agency | EG-GiCUC |
Language of cataloging | eng |
Transcribing agency | EG-GiCUC |
041 0# - LANGUAGE CODE | |
Language code of text/sound track or separate title | eng |
049 ## - LOCAL HOLDINGS (OCLC) | |
Holding library | Deposite |
097 ## - Thesis Degree | |
Thesis Level | M.Sc |
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) | |
Classification number | Cai01.11.31.M.Sc.2020.Am.A |
100 0# - MAIN ENTRY--PERSONAL NAME | |
Personal name | Amr Abdulrahim Said Ibrahim |
245 10 - TITLE STATEMENT | |
Title | Assessment of the central venous pressure via ultrasonography of the internal jugular vein in hemodialysis patients / |
Statement of responsibility, etc. | Amr Abdulrahim Said Ibrahim ; Supervised Aboelmagd Albohy , Ahmed Abdalrahman Baz , Hussein Saeed Hussein Elfishawy |
246 15 - VARYING FORM OF TITLE | |
Title proper/short title | تقدير ضغط الدم الوريدى المركزى بالموجات فوق الصوتية على الوريد الودجى الداخلى فى مرضى غسيل الكلى |
260 ## - PUBLICATION, DISTRIBUTION, ETC. | |
Place of publication, distribution, etc. | Cairo : |
Name of publisher, distributor, etc. | Amr Abdulrahim Said Ibrahim , |
Date of publication, distribution, etc. | 2020 |
300 ## - PHYSICAL DESCRIPTION | |
Extent | 90 P. : |
Other physical details | charts , facimiles ; |
Dimensions | 25cm |
502 ## - DISSERTATION NOTE | |
Dissertation note | Thesis (M.Sc.) - Cairo University - Faculty of Medicine - Department of Radio - Diagnosis |
520 ## - SUMMARY, ETC. | |
Summary, etc. | Introduction: Central venous pressure is among the most widely used parameters to assess for hydration status in renal dialysis patients and guiding fluid therapy. However, assessment of CVP via insertion of a central venous catheter is an invasive procedure which carries variable risks. The aim of the work: To investigate the accuracy of CVP measured by ultrasonography of the internal jugular vein in hemodialysis patients in comparison with CVP measured via central venous catheter. Materials and methods: The current study included one hundred and six patients. All patients were subjected to assessment of CVP through the already applied central venous catheters as well as by high resolution ultrasound of the internal jugular vein.Two ultrasonographic methods were used, in method 1 the vertical height between collapsing point of IJV and sternal angle was measured then 5 cmH20 were added, while in method 2 the calculation of IJV/CCA cross-sectional area ratio was done. Results: A highly significant positive correlation was found between both method1 and method 2 and the invasive CVP measurement through central venous catheter(CVPi), while there was no significant correlation was found between patient sex, presence of DM, presence of HTN or the examined side, and between CVPi. Conclusion: Ultrasonography of the internal jugular vein appears to be a simple, cheap, reliable and non-invasive technique which could be used for repeated monitoring of the central venous pressure even in the patients dialyzed using an arteriovenous fistula and consequently do not have a central venous line available |
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE | |
Additional physical form available note | Issued also as CD |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Central venous pressure |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Internal jugular vein |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Ultrasonography |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Aboelmagd Albohy , |
Relator term | |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Ahmed Abdalrahman Baz , |
Relator term | |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Hussein Saeed Hussein Elfishawy , |
Relator term | |
856 ## - ELECTRONIC LOCATION AND ACCESS | |
Uniform Resource Identifier | <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a> |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) | |
Cataloger | Nazla |
Reviser | Revisor |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) | |
Cataloger | Shimaa |
Reviser | Cataloger |
942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
Source of classification or shelving scheme | Dewey Decimal Classification |
Koha item type | Thesis |
Source of classification or shelving scheme | Not for loan | Home library | Current library | Date acquired | Full call number | Barcode | Date last seen | Koha item type | Copy number |
---|---|---|---|---|---|---|---|---|---|
Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | قاعة الرسائل الجامعية - الدور الاول | 11.02.2024 | Cai01.11.31.M.Sc.2020.Am.A | 01010110082655000 | 22.09.2023 | Thesis | ||
Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | مخـــزن الرســائل الجـــامعية - البدروم | 11.02.2024 | Cai01.11.31.M.Sc.2020.Am.A | 01020110082655000 | 22.09.2023 | CD - Rom | 82655.CD |