Simulation and economic assessment of solar desalination by air humidifaction-dehumidifaction / (Record no. 80497)

MARC details
000 -LEADER
fixed length control field 02195cam a2200325 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 210403s2020 ua d f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.13.04.M.Sc.2020.Es.S
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Esraa Khaled Mohamed Hefny
245 10 - TITLE STATEMENT
Title Simulation and economic assessment of solar desalination by air humidifaction-dehumidifaction /
Statement of responsibility, etc. Esraa Khaled Mohamed Hefny ; Supervised Omer Elfarouk Abdelsalam , Ahmed Soilman Mohamed , Ibrahim Mohamed Ismail
246 15 - VARYING FORM OF TITLE
Title proper/short title المحاكاة والتقييم الاقتصادى للتحلية المياة بالطاقة الشمسية بواسطة الترطيب بالهواء ثم تجفيفه
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Esraa Khaled Mohamed Hefny ,
Date of publication, distribution, etc. 2020
300 ## - PHYSICAL DESCRIPTION
Extent 144 P. :
Other physical details charts , facsimiles ;
Dimensions 30cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Engineering - Department of Chemical Engineering
520 ## - SUMMARY, ETC.
Summary, etc. This study mainly depends on solar desalination by humidification dehumidification method, this work divided into two parts: theoretical study and simulation study.Theoretical study depends on papers that already published in journals, and also climate of Egypt in both summer and winter case, the aim of studying climate is to know both suitable solar radiation and rate of evaporation and condensation, while simulation study depends on data from published paper, after doing mass and heat balance from simulation program, the parameters used are ratio between air to saline water, air temperature, recovery ratio, and specific energy consumption. Simple design of equipment is calculated, in order to know cost of fresh water, the maximum capacity of fresh water is 347 m3/hr with cost 1.14 $/m³
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Aspen Plus simulation
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Humidification-dehumidification
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Solar Desalination
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Ahmed Soilman Mohamed ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Ibrahim Mohamed Ismail ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Omer Elfarouk Abdelsalam ,
Relator term
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Shimaa
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.13.04.M.Sc.2020.Es.S 01010110083168000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.13.04.M.Sc.2020.Es.S 01020110083168000 22.09.2023 CD - Rom 83168.CD