Comparative study between the diagnostic accuracy of 3D-Saline Infusion Sonohysterography and Office Hysteroscopy in assessment of uterine cavity after hysteroscopic septum resection / (Record no. 80746)
[ view plain ]
000 -LEADER | |
---|---|
fixed length control field | 03771cam a2200349 a 4500 |
003 - CONTROL NUMBER IDENTIFIER | |
control field | EG-GiCUC |
005 - DATE AND TIME OF LATEST TRANSACTION | |
control field | 20250223032731.0 |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
fixed length control field | 210424s2020 ua dh f m 000 0 eng d |
040 ## - CATALOGING SOURCE | |
Original cataloging agency | EG-GiCUC |
Language of cataloging | eng |
Transcribing agency | EG-GiCUC |
041 0# - LANGUAGE CODE | |
Language code of text/sound track or separate title | eng |
049 ## - LOCAL HOLDINGS (OCLC) | |
Holding library | Deposite |
097 ## - Thesis Degree | |
Thesis Level | Ph.D |
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) | |
Classification number | Cai01.11.15.Ph.D.2020.Ah.C |
100 0# - MAIN ENTRY--PERSONAL NAME | |
Personal name | Ahmed Shaban Ali Shehata |
245 10 - TITLE STATEMENT | |
Title | Comparative study between the diagnostic accuracy of 3D-Saline Infusion Sonohysterography and Office Hysteroscopy in assessment of uterine cavity after hysteroscopic septum resection / |
Statement of responsibility, etc. | Ahmed Shaban Ali Shehata ; Supervised Mostafa Mohamed Elsadek , Bahaa Eldeen Mohamed Saad Hammad , Hassan Mostafa Gaafar |
246 15 - VARYING FORM OF TITLE | |
Title proper/short title | دراسة مقارنة بين الدقة التشخيصية للتصوير بالموجات فوق الصوتية ثلاثية الأبعاد بالتسريب بمحلول ملحى وتنظير الرحم المكتبي في تقييم تجويف الرحم بعد عمليات استئصال الحاجز الرحمى بالمنظار الرحمى الجراحى |
260 ## - PUBLICATION, DISTRIBUTION, ETC. | |
Place of publication, distribution, etc. | Cairo : |
Name of publisher, distributor, etc. | Ahmed Shaban Ali Shehata , |
Date of publication, distribution, etc. | 2020 |
300 ## - PHYSICAL DESCRIPTION | |
Extent | 128 P. : |
Other physical details | charts , facimiles ; |
Dimensions | 25cm |
502 ## - DISSERTATION NOTE | |
Dissertation note | Thesis (Ph.D.) - Cairo University - Faculty of Medicine - Department of Gynecology and Obstetrics |
520 ## - SUMMARY, ETC. | |
Summary, etc. | Objective: The aim of this study was to compare the diagnostic accuracy of 3D-SIS with of{uFB01}ce Hysteroscopy (control) regarding uterine cavity assessment after hysteroscopic septum resection and their agreement in uterine cavity assessment after hysteroscopic septum resection Methods: 50 patients with uterine septum confirmed by 3D-SIS, complaining of infertility or recurrent miscarriages were recruited from infertility clinic, Kasr Al Ainy hospital, Faculty of medicine, Cairo University over 1 year from February 2019 to February 2020. Hysteroscopic septum resection was done at Kasr Al Ainy hospital operative theatre. Eight weeks later, 3D-SIS was done during the postmenstrual phase by the same investigator for all patients, it was done on the same day immediately before second look office hysteroscopy done by the same investigator using calibrated instruments and patients did not receive any medication between the procedures. Outcome measures: Preoperatively, length, width of septum and residual cavity lengths were assessed by 3D-SIS. Postoperatively, length of fundal notch (residual septum), residual cavity length, and presence or absence of intrauterine adhesions were assessed by 3D-SIS and office hysteroscopy.Primary outcome: comparison between the results of the 3D-SIS and office hysteroscopy done after hysteroscopic septum resection and agreement of 3D-SIS in evaluation of uterine cavity postoperatively. Secondary outcome: comparison between the results of the 3D-SIS done before and after the septum resection. Results: our study showed no significant differences between results of 3D SIS and office hysteroscopy regarding length of fundal notch (P value 0.215) and residual cavity length (P value 0.661), and it showed very good agreement between their results (P value <0.001). Regarding intrauterine adhesions detection, 3D-SIS showed sensitivity 55%, specificity 100%, PPV 100%, NPV 91% with 92% accuracy and good agreement to the results of the office hysteroscopy by Kappa method (K=0.672) |
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE | |
Additional physical form available note | Issued also as CD |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Septate uterus |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Septum resection |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Uterine septum |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Bahaa Eldeen Mohamed Saad Hammad , |
Relator term | |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Hassan Mostafa Gaafar , |
Relator term | |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Mostafa Mohamed Elsadek , |
Relator term | |
856 ## - ELECTRONIC LOCATION AND ACCESS | |
Uniform Resource Identifier | <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a> |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) | |
Cataloger | Nazla |
Reviser | Revisor |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) | |
Cataloger | Shimaa |
Reviser | Cataloger |
942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
Source of classification or shelving scheme | Dewey Decimal Classification |
Koha item type | Thesis |
Source of classification or shelving scheme | Not for loan | Home library | Current library | Date acquired | Full call number | Barcode | Date last seen | Koha item type | Copy number |
---|---|---|---|---|---|---|---|---|---|
Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | قاعة الرسائل الجامعية - الدور الاول | 11.02.2024 | Cai01.11.15.Ph.D.2020.Ah.C | 01010110083320000 | 22.09.2023 | Thesis | ||
Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | مخـــزن الرســائل الجـــامعية - البدروم | 11.02.2024 | Cai01.11.15.Ph.D.2020.Ah.C | 01020110083320000 | 22.09.2023 | CD - Rom | 83320.CD |