header

Assessment of patient specific titanium implant for immediate tooth replacement : (Record no. 81199)

MARC details
000 -LEADER
fixed length control field 02332cam a2200349 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223032746.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 210606s2019 ua dho f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.09.13.M.Sc.2019.Ah.A
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Ahmed Tarek Taher
245 10 - TITLE STATEMENT
Title Assessment of patient specific titanium implant for immediate tooth replacement :
Remainder of title A randomized clinical trial /
Statement of responsibility, etc. Ahmed Tarek Taher ; Supervised Sameh Mekhemer , Mohamed Farid Shehab , Khalid Abdelghany
246 15 - VARYING FORM OF TITLE
Title proper/short title تقييم زرع محدد لاستبدال الأسنان فوراً :
Remainder of title تجربة سريرية عشوائية
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Ahmed Tarek Taher ,
Date of publication, distribution, etc. 2019
300 ## - PHYSICAL DESCRIPTION
Extent 87 P. :
Other physical details charts , facsimiles , photoghraphs ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Oral and Maxillofacial Surgery
520 ## - SUMMARY, ETC.
Summary, etc. This randomized clinical trial was conducted on 20 patients to evaluate the primary stability and the marginal bone loss of 10 root-analogue DLMS titanium implants and 10 immediate conventional titanium implants at the time of implant insertion and after 6 months follow{u2013}up.This approach could have some advantages, such as uncomplicated immediate implant placement, and decrease in treatment time with fewer surgical interventions, with increased patient comfort moreover, DLMS produce implants with superior mechanical properties by varying the porosity of the bulk and surface material thus enhancing osseointegration. Primary stability was evaluated by periotest while marginal bone loss was measured by CBCT. Although RAIs showed low PTVs (high stability) compared with conventional implants ,marginal bone loss was noticed especially buccal bone loss and this may be due to inaccuracies related to CBCT and DLMS process
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Immediate tooth replacement
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Periotest values (PTVs)
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Titanium
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Khalid Abdelghany ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Mohamed Farid Shehab ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Sameh Mekhemer ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Shimaa
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.09.13.M.Sc.2019.Ah.A 01010110083606000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.09.13.M.Sc.2019.Ah.A 01020110083606000 22.09.2023 CD - Rom 83606.CD