header

Retention strength of polyetheretherketone crowns Vs. zirconia crowns restoring molar teeth : (Record no. 81584)

MARC details
000 -LEADER
fixed length control field 03880cam a2200337 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223032758.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 210802s2020 ua dh f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.09.09.M.Sc.2020.He.R
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Hebat Allah Mohammad Hassan Sayed
245 10 - TITLE STATEMENT
Title Retention strength of polyetheretherketone crowns Vs. zirconia crowns restoring molar teeth :
Remainder of title An in vitro study /
Statement of responsibility, etc. Hebat Allah Mohammad Hassan Sayed ; Supervised Hesham Alansary , Lamia Kheiralla
246 15 - VARYING FORM OF TITLE
Title proper/short title قوة الاستبقاء للتيجان المصنوعة من مادة (البولى ايثر ايثر كيتون) مقارنة بالتيجان المصنوعة من الزيركون لإستعاضة الضروس :
Remainder of title دراسة معملية
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Hebat Allah Mohammad Hassan Sayed ,
Date of publication, distribution, etc. 2020
300 ## - PHYSICAL DESCRIPTION
Extent 125 P. :
Other physical details charts , facsimiles ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine- Department of Prosthodontics
520 ## - SUMMARY, ETC.
Summary, etc. Aim: This study was designed to evaluate the retention strength of monolithic CAD/CAM PEEK crowns versus that of CAD/CAM monolithic 5Y-TZP zirconia crowns, both resin-cemented to epoxy resin die abutments resembling lower molar tooth, after thermomechanical aging simulating 3 months of clinical service. Methodology: 22 identical epoxy dies, resembling the preparation of a lower second molar abutment for full-coverage crown (4 mm height, 6{u00B0} axial convergence and 1 mm-thick deep-chamfer finish line), were produced by replicating one master stainless steel die via 22 vinylpolysiloxane impressions. The 22 epoxy dies were randomly equally distributed into 2 groups, 11 dies each; control group 2Zr3 to receive CAD/CAM milled monolithic 5Y-TZP crowns (KATANA{u2122} Zirconia ML), and intervention group 2P3 to receive CAD/CAM milled monolithic PEEK crowns (breCAM.BioHPP{u2122}). Two opposing, laterally projecting arms (mesial and distal) were included in the design of all crowns for the retention test. The fitting surfaces of all crowns of both groups were sandblasted with 110-æm alumina particles.All of the crowns of both groups were cemented over their corresponding epoxy dies using the hand-mixed dual-cured, self-adhesive resin cement (RelyX{u2122} U200 Clicker{u2122} Dispenser) (3-kg seating force). Samples were stored in a water incubator (37 {u00B0}C) for 24 hours; then, subjected to mechanical aging (37,500 cycles, 49 N load) with simultaneous thermocycling (300 cycles, 5-55 {u00B0}C, 12 s dwell time).Retention strength was evaluated through the pull-off test performed via a universal testing machine (UTM), by vertically pulling-up the crowns from their dies along their vertical axes.The mean dislodgement force (retention strength) for each group was calculated, and statistically compared using Student t-test. Statistical analysis was performed with three-way ANOVA. Pair-wise comparison of groups was made with the Tukey test. Pearson{u2019}s Chi-Square test was used to analyze the failure modes. Results: PEEK crowns group (P) has demonstrated statistically insignificant higher retention strength (171.28 N ± 26.30) than zirconia (Zr) crowns group (150.40 N ± 24.40).2Mixed3 failure mode was the predominant in both groups, followed by 2cement on-crown3 failure mode.Though, the material had a significant effect on the percentage of occurrence of failure modes
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Polyetheretherketone crowns
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Restoring molar teeth
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Zirconia crowns
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Hesham Alansary ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Lamia Kheiralla ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Shimaa
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.09.09.M.Sc.2020.He.R 01010110083835000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.09.09.M.Sc.2020.He.R 01020110083835000 22.09.2023 CD - Rom 83835.CD