header

The validity of electrical cardiometry to predict positive fluid challenge test in mechanically ventilated surgical cardiac patients : (Record no. 81693)

MARC details
000 -LEADER
fixed length control field 02714cam a2200349 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223032801.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 210814s2021 ua dh f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.11.01.M.Sc.2021.Ah.V
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Ahmed Raafat Taha
245 14 - TITLE STATEMENT
Title The validity of electrical cardiometry to predict positive fluid challenge test in mechanically ventilated surgical cardiac patients :
Remainder of title A prospective observational study/
Statement of responsibility, etc. Ahmed Raafat Taha ; Supervised Maged Salah Abdallah , Mohamed Ali Bakry , Amr Kamal Abdelhakim
246 15 - VARYING FORM OF TITLE
Title proper/short title صلاحية جهاز قياس القلب الكهربائى للتنبؤ باختبار تحدى السوائل الإيجابى فى مرضى جراحة القلب
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Ahmed Raafat Taha ,
Date of publication, distribution, etc. 2021
300 ## - PHYSICAL DESCRIPTION
Extent 68 P. :
Other physical details charts , facsimiles ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Medicine - Department of Anesthesia
520 ## - SUMMARY, ETC.
Summary, etc. Introduction: Cardiovascular surgeries are major operations that are associated with changes in cardiac output. Electrical Cardiometry is a non-invasive, simple mechanism for estimation of stroke volume and cardiac output. Objectives: we aimed to test the validity of electrical cardiometrey in predicting fluid responsiveness in cardiac surgical patients postoperatively. Materials and Methods: This was an observational study in 38 patients undergoing cardiac surgery, Before and after fluid bolus hemodynamic data was recorded, VTI was measured by TTE as well as SV measured by EC , we evaluated the accuracy of the change in SV after fluid bolus to predict 15% increase in VTI measured by Echocardiography. Results: There was a strong correlation between the change in SV and the change in VTI in predicting fluid responsiveness with Spearman correlation coefficient (95% confidence interval [CI]) of 0.81 (-6.06, +21.05), however there is no correlation between the absolute values of SVEC and VTITTE. Conclusion: Cardiometry can be used as a non-invasive tool to predict positive fluid challenge test in cardiac surgical patients postoperatively and can guide postoperative fluid management in this type of patients
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Predict positive fluid
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Surgical cardiac patients
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Validity of electrical cardiometry
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Amr Kamal Abdelhakim ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Maged Salah Abdallah ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Mohamed Ali Bakry ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Shimaa
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.11.01.M.Sc.2021.Ah.V 01010110083898000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.11.01.M.Sc.2021.Ah.V 01020110083898000 22.09.2023 CD - Rom 83898.CD