header

Face-lifting through high intensity focused ultrasound versus threads : (Record no. 82100)

MARC details
000 -LEADER
fixed length control field 03065cam a2200337 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223032814.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 210912s2021 ua dh f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.11.10.M.Sc.2021.Me.F
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Menatallah Mohamed Ahmed Hassan Omar
245 10 - TITLE STATEMENT
Title Face-lifting through high intensity focused ultrasound versus threads :
Remainder of title A Comparative study /
Statement of responsibility, etc. Menatallah Mohamed Ahmed Hassan Omar ; Supervised Omar Ahmed Azzam , Mona Mohamed Ibrahim Elkalioby
246 15 - VARYING FORM OF TITLE
Title proper/short title شد الوجه الغير جراحى عن طريق جهاز الموجات الفوق صوتية المكثفة مقابل خيوط الوجه الغير دائمة :
Remainder of title دراسة مقارنة
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Menatallah Mohamed Ahmed Hassan Omar ,
Date of publication, distribution, etc. 2021
300 ## - PHYSICAL DESCRIPTION
Extent 170 P. :
Other physical details charts , facsimiles ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc) - Cairo University - Faculty of Medicine - Department of Dermatology
520 ## - SUMMARY, ETC.
Summary, etc. Objective: To compare the efficacy and safety of high intensity focused Ultrasound (HIFU) versus absorbable threads for face lifting. Methods: Twenty females aged from 30 to 60 with moderate facial sagging were randomized into Group A (10 patients) who received a single session of HIFU and Group B (10 patients) who underwent thread procedure. Patients were assessed by a blinded independent investigator after 1 month and 3 months of the procedures. Results:Both HIFU and threads groups showed statistically significant improvement in Merz Aesthetics Scale for jawline after 3 months (p value= 0.003, 0.007 respectively). Although the percent of improvement was higher among threads group compared to HIFU group, the difference wasn{u2019}t significant (p value= 0.349). The improvement was earlier among threads group with statistical significance at 1 month (p value= 0.020), compared to non-statistical significance for HIFU at 1 month (p value= 0.180). There was an associated improvement in the nasolabial fold, marionette lines, submental area, texture and wrinkles with no statistically significant difference between both groups (p value = 0.052, 0.632, 0.952, 0.141, 0.317 respectively). Edema as an adverse effect was statistically more frequent among threads group (p value = 0.016), still patients who underwent threads were significantly more satisfied (p value= 0.020 Among HIFU group, improvement in Merz Aesthetics Scale for jawline showed a negative correlation with baseline Merz Aesthetics Scale for jawline(R= -0.808, P=0.005) moderate facial sagging are better candidates for HIFU than patients with excessive sagging
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Face anatomy
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Face-lifting
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term High intensity focused Ultrasound (HIFU)
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Mona Mohamed Ibrahim Elkalioby ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Omar Ahmed Azzam ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Shimaa
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.11.10.M.Sc.2021.Me.F 01010110084160000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.11.10.M.Sc.2021.Me.F 01020110084160000 22.09.2023 CD - Rom 84160.CD