header

Power system operation in the presence of flexible prosumers considering system congestion / (Record no. 82705)

MARC details
000 -LEADER
fixed length control field 02093cam a2200313 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 211020s2021 ua d f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.13.07.M.Sc.2021.Ma.P
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Mayar Mohsen Mostafa Madboly
245 10 - TITLE STATEMENT
Title Power system operation in the presence of flexible prosumers considering system congestion /
Statement of responsibility, etc. Mayar Mohsen Mostafa Madboly ; Supervised Mohamed Salah Elsobki , Amgad Amin Eldeib
246 15 - VARYING FORM OF TITLE
Title proper/short title التشغيل الأمثل لنظم القوى الكهربية فى وجود الأحمال المرنة وأثناء اختناقات النظام
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Mayar Mohsen Mostafa Madboly ,
Date of publication, distribution, etc. 2021
300 ## - PHYSICAL DESCRIPTION
Extent 126 P. :
Other physical details charts ;
Dimensions 30cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Engineering - Department of Electrical Power and Machines
520 ## - SUMMARY, ETC.
Summary, etc. In this thesis, the optimal operation of the power system is studied using different objective functions: minimum total generation cost, minimum active power losses, minimum specific generation cost, minimum average energy cost. The effect of congestion on the voltage and reactive power output as well as the system performance is analyzed. The system performance is assessed through some key performance indices. Two IEEE benchmark systems which are IEEE 5-bus and 14-bus systems were used to test the formulations and algorithms. The model also includes variable loads and prosumers whose presence proved to be effective in dealing with power system congestion.The use of flexible loads and prosumers benefited the power system by reducing the system costs and losses. Additionally, the voltage profile of the system was enhanced
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Flexible prosumers
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Optimal power flow
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Optimization
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Amgad Amin Eldeib ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Mohamed Salah Elsobki ,
Relator term
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Shimaa
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.13.07.M.Sc.2021.Ma.P 01010110084485000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.13.07.M.Sc.2021.Ma.P 01020110084485000 22.09.2023 CD - Rom 84485.CD