The accuracy of implant placement using opened versus closed sleeve computer guided surgical guide : (Record no. 83058)
[ view plain ]
000 -LEADER | |
---|---|
fixed length control field | 02560cam a2200337 a 4500 |
003 - CONTROL NUMBER IDENTIFIER | |
control field | EG-GiCUC |
005 - DATE AND TIME OF LATEST TRANSACTION | |
control field | 20250223032844.0 |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
fixed length control field | 211108s2018 ua dh f m 000 0 eng d |
040 ## - CATALOGING SOURCE | |
Original cataloging agency | EG-GiCUC |
Language of cataloging | eng |
Transcribing agency | EG-GiCUC |
041 0# - LANGUAGE CODE | |
Language code of text/sound track or separate title | eng |
049 ## - LOCAL HOLDINGS (OCLC) | |
Holding library | Deposite |
097 ## - Thesis Degree | |
Thesis Level | M.Sc |
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) | |
Classification number | Cai01.09.09.M.Sc.2018.Sa.A |
100 0# - MAIN ENTRY--PERSONAL NAME | |
Personal name | Samah Ahmed Sharaka |
245 14 - TITLE STATEMENT | |
Title | The accuracy of implant placement using opened versus closed sleeve computer guided surgical guide : |
Remainder of title | A split mouth technique / |
Statement of responsibility, etc. | Samah Ahmed Sharaka ; Supervised Amal Fathy Kaddah , Amr Hosny Elkhadem |
246 15 - VARYING FORM OF TITLE | |
Title proper/short title | دقه وضع غرسات الاسنان باستخدام اله جراحيه مفتوحه ومغلقه بالكمبيوتر باستخدام اكمام |
260 ## - PUBLICATION, DISTRIBUTION, ETC. | |
Place of publication, distribution, etc. | Cairo : |
Name of publisher, distributor, etc. | Samah Ahmed Sharaka , |
Date of publication, distribution, etc. | 2018 |
300 ## - PHYSICAL DESCRIPTION | |
Extent | 98 P. : |
Other physical details | charts , facsimiles ; |
Dimensions | 25cm |
502 ## - DISSERTATION NOTE | |
Dissertation note | Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontics |
520 ## - SUMMARY, ETC. | |
Summary, etc. | The aim of this study was to find the difference in accuracy of implant placement using open versus closed surgical guide using split mouth technique. 18 pairs of implant were enrolled in this study as about 9 patients. A split mouth technique randomized clinical trial was the study design. Open sleeves were used in one side of surgical guide and closed sleeve in the other side. Each patient was received four implant, which were divided in two implants in each side. Radiographic template was made for each patient according to do examination CBCT.The cone-beam computed tomography was obtained as DICON (digital imaging and communications in medicine) data then imported into the Blue Sky in which the location of four implants of each suspected arch were planned in three dimensions.Then a three-dimensional virtual stent was designed then processed by a rapid prototyping unit which built it from a photo curable resin material (stereolithography) Surgical stent was fixed to it is position by light cure flowable composite then the osteotomy sites were prepared.The implants then were inserted through the surgical guide. Another CBCT was taken after surgery to show the actual placed implant |
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE | |
Additional physical form available note | Issued also as CD |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Closed sleeve computer |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Guided surgical guide |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Implant placement |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Amal Fathy Kaddah , |
Relator term | |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Amr Hosny Elkhadem , |
Relator term | |
856 ## - ELECTRONIC LOCATION AND ACCESS | |
Uniform Resource Identifier | <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a> |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) | |
Cataloger | Nazla |
Reviser | Revisor |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) | |
Cataloger | Shimaa |
Reviser | Cataloger |
942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
Source of classification or shelving scheme | Dewey Decimal Classification |
Koha item type | Thesis |
Source of classification or shelving scheme | Not for loan | Home library | Current library | Date acquired | Full call number | Barcode | Date last seen | Koha item type | Copy number |
---|---|---|---|---|---|---|---|---|---|
Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | قاعة الرسائل الجامعية - الدور الاول | 11.02.2024 | Cai01.09.09.M.Sc.2018.Sa.A | 01010110084701000 | 22.09.2023 | Thesis | ||
Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | مخـــزن الرســائل الجـــامعية - البدروم | 11.02.2024 | Cai01.09.09.M.Sc.2018.Sa.A | 01020110084701000 | 22.09.2023 | CD - Rom | 84701.CD |