MARC details
000 -LEADER |
fixed length control field |
02797cam a2200325 a 4500 |
003 - CONTROL NUMBER IDENTIFIER |
control field |
EG-GiCUC |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
fixed length control field |
211114s2021 ua dh f m 000 0 eng d |
040 ## - CATALOGING SOURCE |
Original cataloging agency |
EG-GiCUC |
Language of cataloging |
eng |
Transcribing agency |
EG-GiCUC |
041 0# - LANGUAGE CODE |
Language code of text/sound track or separate title |
eng |
049 ## - LOCAL HOLDINGS (OCLC) |
Holding library |
Deposite |
097 ## - Thesis Degree |
Thesis Level |
Ph.D |
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) |
Classification number |
Cai01.11.25.Ph.D.2021.Mo.R |
100 0# - MAIN ENTRY--PERSONAL NAME |
Personal name |
Mohammed Mazher Mohammed Saif |
245 10 - TITLE STATEMENT |
Title |
Results of dynamic hip screw with trochanteric stabilizing plate in treatment of unstable trochanteric hip fractures / |
Statement of responsibility, etc. |
Mohammed Mazher Mohammed Saif ; Supervised Mohamed Omar Soliman , Mohamed Said Abdelmaksoud , Mohamed Ahmed Abdelmoneim |
246 15 - VARYING FORM OF TITLE |
Title proper/short title |
نتائج استخدام الشريخة المنزلقة مع الشريحة المثبتة الخارجية فى علاج حالات كسور مابين المدورين الغير مستقرة |
260 ## - PUBLICATION, DISTRIBUTION, ETC. |
Place of publication, distribution, etc. |
Cairo : |
Name of publisher, distributor, etc. |
Mohammed Mazher Mohammed Saif , |
Date of publication, distribution, etc. |
2021 |
300 ## - PHYSICAL DESCRIPTION |
Extent |
101 P. : |
Other physical details |
charts , facsimiles ; |
Dimensions |
25cm |
502 ## - DISSERTATION NOTE |
Dissertation note |
Thesis (Ph.D.) - Cairo University - Faculty of Medicine - Department of Orthopedics Surgery |
520 ## - SUMMARY, ETC. |
Summary, etc. |
Background: Trochanteric hip fractures are common among elderly patients. Integrity of lateral wall is important to prevent excessive fracture collapse and poor outcome. DHS with TSP is considered a good treatment option for unstable trochanteric fracture. It prevents lateral wall fracture and medialization. We study the radiological and functional outcome and the complications of using TSP in unstable trochanteric fractures A2-2, A2-3 and A3-3. Patients and methods: 40 patients with unstable hip fractures were operated in KasrAlainy Hospital using DHS with TSP.The mean age was 65.78 years. Patients were followed up prospectively for a minimum of 18 months. Patients were assessed radiographically and clinically using Harris hip score (HHS) at 3,6,12 and 18 months. Results: Time to bony union ranged from 11 weeks to 22 weeks with mean of 16.38±3.01 weeks. At 3 months the HSS ranged from 43 to 89 points, the mean was 70.22±12.65 points. At 6 months the HSS ranged from 50 to 100 points, the mean was 82.81±10.37 points. At 12 months the HSS ranged from 55 to 100 points, the mean was 89.09±9.20 points. At 18 months the HSS ranged from 62 to 100 points, the mean was 93.84±7.95 points. Conclusion: Using DHS with TSP in unstable trochanteric fractures is a good treatment option with good functional outcomes and minimal complications |
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE |
Additional physical form available note |
Issued also as CD |
653 #4 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
Dynamic hip screw |
653 #4 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
Hip fractures |
653 #4 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
Trochanteric stabilizing plate |
700 0# - ADDED ENTRY--PERSONAL NAME |
Personal name |
Mohamed Ahmed Abdelmoneim , |
Relator term |
|
700 0# - ADDED ENTRY--PERSONAL NAME |
Personal name |
Mohamed Omar Soliman , |
Relator term |
|
700 0# - ADDED ENTRY--PERSONAL NAME |
Personal name |
Mohamed Said Abdelmaksoud , |
Relator term |
|
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) |
Cataloger |
Nazla |
Reviser |
Revisor |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) |
Cataloger |
Shimaa |
Reviser |
Cataloger |
942 ## - ADDED ENTRY ELEMENTS (KOHA) |
Source of classification or shelving scheme |
Dewey Decimal Classification |
Koha item type |
Thesis |