Ionising radiation dose calculation for the realse of I¹³¹ during accident conditions for materials test reactor / (Record no. 83163)
[ view plain ]
000 -LEADER | |
---|---|
fixed length control field | 02467cam a2200325 a 4500 |
003 - CONTROL NUMBER IDENTIFIER | |
control field | EG-GiCUC |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
fixed length control field | 211115s2021 ua dh f m 000 0 eng d |
040 ## - CATALOGING SOURCE | |
Original cataloging agency | EG-GiCUC |
Language of cataloging | eng |
Transcribing agency | EG-GiCUC |
041 0# - LANGUAGE CODE | |
Language code of text/sound track or separate title | eng |
049 ## - LOCAL HOLDINGS (OCLC) | |
Holding library | Deposite |
097 ## - Thesis Degree | |
Thesis Level | M.Sc |
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) | |
Classification number | Cai01.12.20.M.Sc.2021.Ma.I |
100 0# - MAIN ENTRY--PERSONAL NAME | |
Personal name | Mahmoud Ramadan Mohamed Mahmoud Aboeross |
245 10 - TITLE STATEMENT | |
Title | Ionising radiation dose calculation for the realse of I¹³¹ during accident conditions for materials test reactor / |
Statement of responsibility, etc. | Mahmoud Ramadan Mohamed Mahmoud Aboeross ; Supervised Esmat Hanem Amin , Abdallah AbdelSalam Mohamed , Wafaa Osman Bahr |
246 15 - VARYING FORM OF TITLE | |
Title proper/short title | حسابات الجرع الاشعاعية المؤينة لانطلاق اليود 131 الناتج من حالات الحوادث لمفاعل اختيار المواد |
260 ## - PUBLICATION, DISTRIBUTION, ETC. | |
Place of publication, distribution, etc. | Cairo : |
Name of publisher, distributor, etc. | Mahmoud Ramadan Mohamed Mahmoud Aboeross , |
Date of publication, distribution, etc. | 2021 |
300 ## - PHYSICAL DESCRIPTION | |
Extent | 79 P. : |
Other physical details | charts , facsimiles ; |
Dimensions | 25cm |
502 ## - DISSERTATION NOTE | |
Dissertation note | Thesis (M.Sc.) - Cairo University - Faculty of Science - Department of Physics |
520 ## - SUMMARY, ETC. | |
Summary, etc. | The doses and dose rates following a Loss of Coolant Accident (LOCA) in Material Test Reactor MTR reactor have been studied. MTR reactor is an open water pool reactor type. The water pool serves as a shield from radioactive radiations. The most serious accident in this type of reactor is the Loss of Coolant Accident (LOCA) due to rupture either of a primary coolant pipe or of any experimental beam tube. In the present work it has been assumed that pool water drains out due to double ended rupture of the tangential irradiation beam tube (TIC) which has a diameter 150 mm. For an operating power level of 22 MW, the equilibrium core would enter into melting conditions if the pool drain time is less than one hour. It was also assumed that Emergency Core Cooling System (chimney water injection system and siphon effect breaker) were not working. Therefore conservatively a severe damage (~80%) is expected to occur to the core, either by a core uncover situation following extended boiling operation, or by a core covered situation with extended boiling |
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE | |
Additional physical form available note | Issued also as CD |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | I¹³¹ |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Materials test reacto |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Radiation dose calculation |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Abdallah Abdelsalam Mohamed , |
Relator term | |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Esmat Hanem Amin , |
Relator term | |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Wafaa Osman Bahr , |
Relator term | |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) | |
Cataloger | Nazla |
Reviser | Revisor |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) | |
Cataloger | Shimaa |
Reviser | Cataloger |
942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
Source of classification or shelving scheme | Dewey Decimal Classification |
Koha item type | Thesis |
Source of classification or shelving scheme | Not for loan | Home library | Current library | Date acquired | Full call number | Barcode | Date last seen | Koha item type | Copy number |
---|---|---|---|---|---|---|---|---|---|
Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | قاعة الرسائل الجامعية - الدور الاول | 11.02.2024 | Cai01.12.20.M.Sc.2021.Ma.I | 01010110084756000 | 22.09.2023 | Thesis | ||
Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | مخـــزن الرســائل الجـــامعية - البدروم | 11.02.2024 | Cai01.12.20.M.Sc.2021.Ma.I | 01020110084756000 | 22.09.2023 | CD - Rom | 84756.CD |