header

Validity and reliability of smartphone goniometer for assessment of joint position sense in patellofemoral pain syndrome / (Record no. 83230)

MARC details
000 -LEADER
fixed length control field 03475cam a2200337 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223032850.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 211121s2021 ua dh f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.21.03.M.Sc.2021.Mo.V
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Mostafa Ahmed Ali Abed
245 10 - TITLE STATEMENT
Title Validity and reliability of smartphone goniometer for assessment of joint position sense in patellofemoral pain syndrome /
Statement of responsibility, etc. Mostafa Ahmed Ali Abed ; Supervised Enas Fawzy Youssef , Dina Mohamed Ali
246 15 - VARYING FORM OF TITLE
Title proper/short title صلاحية و موثوقية تطبيق الجونيوميتر للهاتف الذكى لتقييم إحساس وضع المفصل فى مرضى متلازمة الألم الفخذى البطنى
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Mostafa Ahmed Ali Abed ,
Date of publication, distribution, etc. 2021
300 ## - PHYSICAL DESCRIPTION
Extent 72 P. :
Other physical details charts , facsimiles ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of of Physical Therapy - Department of Musculoskeletal disorders
520 ## - SUMMARY, ETC.
Summary, etc. Background: Proprioception deficiency of the knee is considered one of the most important signs that can be detected in the assessment of individuals with patellofemoral pain syndrome. Objective: To evaluate concurrent validity and reliability of smartphone application [android app clinometer - version 2.4 (16052510)] in assessment of active knee joint position sense in individuals with patellofemoral pain syndrome. Methods: Thirty-two patellofemoral pain syndrome individuals (21 males and 11 females with unilateral symptoms with their age 28.15 ± 5.43 years were included in the study. Active knee joint position sense was measured by isokinetic dynamometer and by smartphone clinometer application at two different angles (30{u02DA} and 60{u02DA}) of knee flexion and the results were compared to examine concurrent validity of the smartphone clinometer application. Measurements taken by the smartphone were repeated on the same day by another experienced examiner to measure inter-rater reliability. After two days, measurements taken by smartphone were repeated by the main examiner to measure intra-rater reliability. Person Product Moment Correlation Coefficient was used to evaluate concurrent validity and Inter class correlation coefficient was used to evaluate intra and inter-rater reliabilities.Results: Smartphone clinometer application was valid in assessing active knee joint position sense at target angle 60{u02DA} but not at 30{u02DA} of knee flexion. At 30{u02DA} there was weak positive non-significant correlation (p = 0.67), (r=0.085), while at 60{u02DA} there was strong positive significant correlation (p = 0.000), (r=0.793). Intra-rater reliability of smartphone clinometer application at 30{u02DA} was negative weak non-significant (p=0.637 (r= -0.095), while it was positive strong significant at 60{u00B0} of knee flexion (p = 0.000) and (r= -0.914). Inter-rater reliability of smartphone clinometer application suggested moderate positive significance at 30{u02DA} (p = 0.000) and (r=0.695) and 60{u00B0} (p = 0.000) and (r=0.899) of knee flexion
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Joint position sense
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Reliability
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Validity
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Dina Mohamed Ali ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Enas Fawzy Youssef ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Shimaa
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.21.03.M.Sc.2021.Mo.V 01010110084785000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.21.03.M.Sc.2021.Mo.V 01020110084785000 22.09.2023 CD - Rom 84785.CD