header

Evaluation of the accuracy of CAD-CAM custom made titanium miniplates in positioning of the genial segment in computer guided genioplasty : (Record no. 83280)

MARC details
000 -LEADER
fixed length control field 02794cam a2200337 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223032851.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 211124s2019 ua dho f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.09.13.M.Sc.2019.Mi.E
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Mina Nazih Zaki Sedrak
245 10 - TITLE STATEMENT
Title Evaluation of the accuracy of CAD-CAM custom made titanium miniplates in positioning of the genial segment in computer guided genioplasty :
Remainder of title Pilot study /
Statement of responsibility, etc. Mina Nazih Zaki Sedrak ; Supervised Nader Nabil Elbokle , Mohammed Mokhtar Yousef Khashaba
246 15 - VARYING FORM OF TITLE
Title proper/short title تقييم استقرار لوحات مخصص التايتينيوم فى وضعية الكمبيوتر الارشادية رأب الذقن :
Remainder of title دراسة تجريبية
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Mina Nazih Zaki Sedrak ,
Date of publication, distribution, etc. 2019
300 ## - PHYSICAL DESCRIPTION
Extent 69 P. :
Other physical details charts , facsimiles , photoghraphs ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dnental Medicine - Department of Oral and Maxillofacial Surgery
520 ## - SUMMARY, ETC.
Summary, etc. This study was conducted on one group of 8 patients (5 females and 3 males), suffering from chin deformities.The patients were evaluated for the chin deformity using the cephalometric analysis. Patient consented to the surgery after acceptance of the procedure. The patient cone beam computed tomography was used to fabricate the custom made miniplate for the genioplasty with a cutting guide for the osteotomy and the predetermined plate screw holes.The procedure was done under general anesthesia. The postoperative cone beam computed tomography was taken 1 month after the surgery. Reference point and planes were taken and measured on the postsimulation and the post-operative CT. Statistical analysis showed non-significant difference between the preoperative post-simulation readings (Pog- Nasion Perpendicular). ( S-N-Pog) and (Pog to right and left mental planes) (P<0.05). Overall superimposition of both Models showed range of accuracy percentage between 72% and 92% with mean value of 82.75% which is considered acceptable in the range. The computer guided genioplasty procedure showed high accuracy in its results. The positioning of the genial segment was facilitated and the operative time was reduced. Patients showed less postoperative hypoesthesia due to the planned cut away from the vital structures
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term CAD-CAM
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Computer guided genioplasty
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Made titanium miniplates
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Mohammed Mokhtar Yousef Khashaba ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Nader Nabil Elbokle ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Shimaa
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.09.13.M.Sc.2019.Mi.E 01010110084825000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.09.13.M.Sc.2019.Mi.E 01020110084825000 22.09.2023 CD - Rom 84825.CD