Evaluation of the accuracy of CAD-CAM custom made titanium miniplates in positioning of the genial segment in computer guided genioplasty : (Record no. 83280)
[ view plain ]
000 -LEADER | |
---|---|
fixed length control field | 02794cam a2200337 a 4500 |
003 - CONTROL NUMBER IDENTIFIER | |
control field | EG-GiCUC |
005 - DATE AND TIME OF LATEST TRANSACTION | |
control field | 20250223032851.0 |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
fixed length control field | 211124s2019 ua dho f m 000 0 eng d |
040 ## - CATALOGING SOURCE | |
Original cataloging agency | EG-GiCUC |
Language of cataloging | eng |
Transcribing agency | EG-GiCUC |
041 0# - LANGUAGE CODE | |
Language code of text/sound track or separate title | eng |
049 ## - LOCAL HOLDINGS (OCLC) | |
Holding library | Deposite |
097 ## - Thesis Degree | |
Thesis Level | M.Sc |
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) | |
Classification number | Cai01.09.13.M.Sc.2019.Mi.E |
100 0# - MAIN ENTRY--PERSONAL NAME | |
Personal name | Mina Nazih Zaki Sedrak |
245 10 - TITLE STATEMENT | |
Title | Evaluation of the accuracy of CAD-CAM custom made titanium miniplates in positioning of the genial segment in computer guided genioplasty : |
Remainder of title | Pilot study / |
Statement of responsibility, etc. | Mina Nazih Zaki Sedrak ; Supervised Nader Nabil Elbokle , Mohammed Mokhtar Yousef Khashaba |
246 15 - VARYING FORM OF TITLE | |
Title proper/short title | تقييم استقرار لوحات مخصص التايتينيوم فى وضعية الكمبيوتر الارشادية رأب الذقن : |
Remainder of title | دراسة تجريبية |
260 ## - PUBLICATION, DISTRIBUTION, ETC. | |
Place of publication, distribution, etc. | Cairo : |
Name of publisher, distributor, etc. | Mina Nazih Zaki Sedrak , |
Date of publication, distribution, etc. | 2019 |
300 ## - PHYSICAL DESCRIPTION | |
Extent | 69 P. : |
Other physical details | charts , facsimiles , photoghraphs ; |
Dimensions | 25cm |
502 ## - DISSERTATION NOTE | |
Dissertation note | Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dnental Medicine - Department of Oral and Maxillofacial Surgery |
520 ## - SUMMARY, ETC. | |
Summary, etc. | This study was conducted on one group of 8 patients (5 females and 3 males), suffering from chin deformities.The patients were evaluated for the chin deformity using the cephalometric analysis. Patient consented to the surgery after acceptance of the procedure. The patient cone beam computed tomography was used to fabricate the custom made miniplate for the genioplasty with a cutting guide for the osteotomy and the predetermined plate screw holes.The procedure was done under general anesthesia. The postoperative cone beam computed tomography was taken 1 month after the surgery. Reference point and planes were taken and measured on the postsimulation and the post-operative CT. Statistical analysis showed non-significant difference between the preoperative post-simulation readings (Pog- Nasion Perpendicular). ( S-N-Pog) and (Pog to right and left mental planes) (P<0.05). Overall superimposition of both Models showed range of accuracy percentage between 72% and 92% with mean value of 82.75% which is considered acceptable in the range. The computer guided genioplasty procedure showed high accuracy in its results. The positioning of the genial segment was facilitated and the operative time was reduced. Patients showed less postoperative hypoesthesia due to the planned cut away from the vital structures |
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE | |
Additional physical form available note | Issued also as CD |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | CAD-CAM |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Computer guided genioplasty |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Made titanium miniplates |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Mohammed Mokhtar Yousef Khashaba , |
Relator term | |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Nader Nabil Elbokle , |
Relator term | |
856 ## - ELECTRONIC LOCATION AND ACCESS | |
Uniform Resource Identifier | <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a> |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) | |
Cataloger | Nazla |
Reviser | Revisor |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) | |
Cataloger | Shimaa |
Reviser | Cataloger |
942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
Source of classification or shelving scheme | Dewey Decimal Classification |
Koha item type | Thesis |
Source of classification or shelving scheme | Not for loan | Home library | Current library | Date acquired | Full call number | Barcode | Date last seen | Koha item type | Copy number |
---|---|---|---|---|---|---|---|---|---|
Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | قاعة الرسائل الجامعية - الدور الاول | 11.02.2024 | Cai01.09.13.M.Sc.2019.Mi.E | 01010110084825000 | 22.09.2023 | Thesis | ||
Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | مخـــزن الرســائل الجـــامعية - البدروم | 11.02.2024 | Cai01.09.13.M.Sc.2019.Mi.E | 01020110084825000 | 22.09.2023 | CD - Rom | 84825.CD |