header

Comparison of patient satisfaction and primary implant stability between two different magnetic attachment for implant retained mandibular over denture following immediate loading : (Record no. 83348)

MARC details
000 -LEADER
fixed length control field 02822cam a2200337 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223032854.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 211129s2021 ua dh f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.09.13.M.Sc.2021.Hu.C
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Hussein Hatam Jawad
245 10 - TITLE STATEMENT
Title Comparison of patient satisfaction and primary implant stability between two different magnetic attachment for implant retained mandibular over denture following immediate loading :
Remainder of title Randomized clinical trial /
Statement of responsibility, etc. Hussein Hatam Jawad ; Supervised Ahmed Mohamed Alsaed Fahmy , Amr Ahmed Naguib
246 15 - VARYING FORM OF TITLE
Title proper/short title المقارنة فى اقتناع المريض للطقم والثبات الأولى للغرسه بين نوعين من المثبتات على الغرسات فى حالات الأطقم المحمولة فى التحميل الفورى
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Hussein Hatam Jawad ,
Date of publication, distribution, etc. 2021
300 ## - PHYSICAL DESCRIPTION
Extent 90 P. :
Other physical details charts , facsimiles ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Oral and Mexillofacal Surgery
520 ## - SUMMARY, ETC.
Summary, etc. Aim: The aim of this study is to assess thepatient satisfaction and primary implant stability of dome magnet attachment design over denture versuspatient satisfaction and primary implant stability of flat magnetic attachment design with immediate loading. Methodology: fourteen patients with completely edentulism were enrolled in this study. Each patient received 2 implants between the canine and lateral incisor area in both side region. The implants were loaded immediately with two magnet attachmentretained over-dentures(flat ,dome magnetic attachment).The Patient satisfaction will be measured in 2 week(base line) and after 12 week by Denture satisfaction questionnaire and Implant stability will be measured for both groups using smart peg /osstellat the day of implant installation and after 2,4,8,12 weeks. Results: Regarding Assessment of Patient Satisfaction After Twelve Weeks of Implant Installation, The statistically significant difference between group 1 and group 2 , which indicate that group one show better improvement than group 2. Regarding Amount of Primary Implant Stability Change during Follow Up for both Groups, according to average of two group at eight and twelve week ,we concluded the group 1 more improvement than group 2
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Magnetic attachment
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Patient satisfaction
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Primary implant stability
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Ahmed Mohamed Alsaed Fahmy ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Amr Ahmed Naguib ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Shimaa
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.09.13.M.Sc.2021.Hu.C 01010110084870000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.09.13.M.Sc.2021.Hu.C 01020110084870000 22.09.2023 CD - Rom 84870.CD