Comparison of patient satisfaction and primary implant stability between two different magnetic attachment for implant retained mandibular over denture following immediate loading : (Record no. 83348)
[ view plain ]
000 -LEADER | |
---|---|
fixed length control field | 02822cam a2200337 a 4500 |
003 - CONTROL NUMBER IDENTIFIER | |
control field | EG-GiCUC |
005 - DATE AND TIME OF LATEST TRANSACTION | |
control field | 20250223032854.0 |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
fixed length control field | 211129s2021 ua dh f m 000 0 eng d |
040 ## - CATALOGING SOURCE | |
Original cataloging agency | EG-GiCUC |
Language of cataloging | eng |
Transcribing agency | EG-GiCUC |
041 0# - LANGUAGE CODE | |
Language code of text/sound track or separate title | eng |
049 ## - LOCAL HOLDINGS (OCLC) | |
Holding library | Deposite |
097 ## - Thesis Degree | |
Thesis Level | M.Sc |
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) | |
Classification number | Cai01.09.13.M.Sc.2021.Hu.C |
100 0# - MAIN ENTRY--PERSONAL NAME | |
Personal name | Hussein Hatam Jawad |
245 10 - TITLE STATEMENT | |
Title | Comparison of patient satisfaction and primary implant stability between two different magnetic attachment for implant retained mandibular over denture following immediate loading : |
Remainder of title | Randomized clinical trial / |
Statement of responsibility, etc. | Hussein Hatam Jawad ; Supervised Ahmed Mohamed Alsaed Fahmy , Amr Ahmed Naguib |
246 15 - VARYING FORM OF TITLE | |
Title proper/short title | المقارنة فى اقتناع المريض للطقم والثبات الأولى للغرسه بين نوعين من المثبتات على الغرسات فى حالات الأطقم المحمولة فى التحميل الفورى |
260 ## - PUBLICATION, DISTRIBUTION, ETC. | |
Place of publication, distribution, etc. | Cairo : |
Name of publisher, distributor, etc. | Hussein Hatam Jawad , |
Date of publication, distribution, etc. | 2021 |
300 ## - PHYSICAL DESCRIPTION | |
Extent | 90 P. : |
Other physical details | charts , facsimiles ; |
Dimensions | 25cm |
502 ## - DISSERTATION NOTE | |
Dissertation note | Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Oral and Mexillofacal Surgery |
520 ## - SUMMARY, ETC. | |
Summary, etc. | Aim: The aim of this study is to assess thepatient satisfaction and primary implant stability of dome magnet attachment design over denture versuspatient satisfaction and primary implant stability of flat magnetic attachment design with immediate loading. Methodology: fourteen patients with completely edentulism were enrolled in this study. Each patient received 2 implants between the canine and lateral incisor area in both side region. The implants were loaded immediately with two magnet attachmentretained over-dentures(flat ,dome magnetic attachment).The Patient satisfaction will be measured in 2 week(base line) and after 12 week by Denture satisfaction questionnaire and Implant stability will be measured for both groups using smart peg /osstellat the day of implant installation and after 2,4,8,12 weeks. Results: Regarding Assessment of Patient Satisfaction After Twelve Weeks of Implant Installation, The statistically significant difference between group 1 and group 2 , which indicate that group one show better improvement than group 2. Regarding Amount of Primary Implant Stability Change during Follow Up for both Groups, according to average of two group at eight and twelve week ,we concluded the group 1 more improvement than group 2 |
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE | |
Additional physical form available note | Issued also as CD |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Magnetic attachment |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Patient satisfaction |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Primary implant stability |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Ahmed Mohamed Alsaed Fahmy , |
Relator term | |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Amr Ahmed Naguib , |
Relator term | |
856 ## - ELECTRONIC LOCATION AND ACCESS | |
Uniform Resource Identifier | <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a> |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) | |
Cataloger | Nazla |
Reviser | Revisor |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) | |
Cataloger | Shimaa |
Reviser | Cataloger |
942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
Source of classification or shelving scheme | Dewey Decimal Classification |
Koha item type | Thesis |
Source of classification or shelving scheme | Not for loan | Home library | Current library | Date acquired | Full call number | Barcode | Date last seen | Koha item type | Copy number |
---|---|---|---|---|---|---|---|---|---|
Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | قاعة الرسائل الجامعية - الدور الاول | 11.02.2024 | Cai01.09.13.M.Sc.2021.Hu.C | 01010110084870000 | 22.09.2023 | Thesis | ||
Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | مخـــزن الرســائل الجـــامعية - البدروم | 11.02.2024 | Cai01.09.13.M.Sc.2021.Hu.C | 01020110084870000 | 22.09.2023 | CD - Rom | 84870.CD |