header

Treatment planning comparison for conventional 3d conformal radiotherapy (3DCRT), intensity modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) / (Record no. 83756)

MARC details
000 -LEADER
fixed length control field 03179cam a2200325 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 220101s2021 ua dh f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.12.04.M.Sc.2021.Ma.T
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Mahmoud Meselhy Ahmed
245 10 - TITLE STATEMENT
Title Treatment planning comparison for conventional 3d conformal radiotherapy (3DCRT), intensity modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) /
Statement of responsibility, etc. Mahmoud Meselhy Ahmed ; Supervised Anwar Abdelazim Aly , Zenab Eltaher Moneir , Heba Mohamed Fahmy
246 15 - VARYING FORM OF TITLE
Title proper/short title مقارنة التخطيط العلاجى الإشعاعى للعلاج التقليدى ثلاثى الابعاد: العلاج الإشعاعى متغير الشدة والعلاج الإشعاعى الحجمى
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Mahmoud Meselhy Ahmed ,
Date of publication, distribution, etc. 2021
300 ## - PHYSICAL DESCRIPTION
Extent 95 P. :
Other physical details charts , facsimiles ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Science - Department of Biophysics
520 ## - SUMMARY, ETC.
Summary, etc. Purpose of work: to study the best planning techniques for post-operative breast radiotherapy, either forward intensity modulated radiation therapy (FIMRT), or inverse intensity modulated radiation therapy (I-IMRT), and volumetric modulated arc therapy (VMAT). Another strategy is to check the dosimetric difference between using 6 or 10 MV energies for both I-IMRT and VMAT. The present study aims to check the impact of shape parameters on organs at risk doses. Materials and Methods: In the present study, four different inverse plans and one forward plan of randomly selected twenty left breast cancer patients were compared dosimetrically. Plans were done on Monaco's (5.1) treatment planning system, and data analyses were accomplished using IBM SPSS (20) data editor software. Results: Inverse planning achieved superior target coverage over forward planning (p-value =0.001,0.07) by about 2-4 % compared to forward planning. Conformity index (p-value <0.05) also improved 0.7 to 0.85 maintaining adequate homogeneity index (p-value = 0.461, 0.138). Left lung and heart high dose levels decreased using I-IMRT, VMAT (p-value <0.05) at the cost of increasing volume irradiated by low doses (p-value <0.05). For contralateral lung, VMAT increased scattered dose over F-IMRT (p< 0.05), but I-IMRT showed a non-significant increase of V5 Gy (p-value = 0.14). For contralateral breast, both I-IMRT and VMAT increased absorbed dose over F-IMRT (P < 0.05). Using high energy for inverse planning increases scattered low dose to organs at risk, and this effect becomes more significant for healthy tissues away from the target than that near it
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Forward intensity modulated radiation therapy (F-IMRT)
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Inverse intensity modulated radiation therapy (I-IMRT)
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Volumetric modulated arc therapy (VMAT)
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Anwar Abdelazim Aly ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Heba Mohamed Fahmy ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Zenab Eltaher Moneir ,
Relator term
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Shimaa
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.12.04.M.Sc.2021.Ma.T 01010110085120000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.12.04.M.Sc.2021.Ma.T 0102011008512000 22.09.2023 CD - Rom 85120.CD