MARC details
000 -LEADER |
fixed length control field |
03345cam a2200325 a 4500 |
003 - CONTROL NUMBER IDENTIFIER |
control field |
EG-GiCUC |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
fixed length control field |
220221s2016 ua dho f m 000 0 eng d |
040 ## - CATALOGING SOURCE |
Original cataloging agency |
EG-GiCUC |
Language of cataloging |
eng |
Transcribing agency |
EG-GiCUC |
041 0# - LANGUAGE CODE |
Language code of text/sound track or separate title |
eng |
049 ## - LOCAL HOLDINGS (OCLC) |
Holding library |
Deposite |
097 ## - Thesis Degree |
Thesis Level |
M.Sc |
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) |
Classification number |
Cai01.09.09.M.Sc.2016.Mo.E |
100 0# - MAIN ENTRY--PERSONAL NAME |
Personal name |
Mohammed Ghulam Mortada |
245 10 - TITLE STATEMENT |
Title |
Effect of platform switching on stresses transmitted to implant supported fixed partial denture : |
Remainder of title |
In-vitro study / |
Statement of responsibility, etc. |
Mohammed Ghulam Mortada ; Supervised Ahmed Hassanien Khalil , Zeinab Nabil Emam |
246 15 - VARYING FORM OF TITLE |
Title proper/short title |
تاثير تغير صفيحة التشكيل على الحمال المنتقلة فى الاستعاضات السنية المثبتة المتكاة على غرسات : |
Remainder of title |
دراسة معمل{u٠٦أأ}ة |
260 ## - PUBLICATION, DISTRIBUTION, ETC. |
Place of publication, distribution, etc. |
Cairo : |
Name of publisher, distributor, etc. |
Mohammed Ghulam Mortada , |
Date of publication, distribution, etc. |
2016 |
300 ## - PHYSICAL DESCRIPTION |
Extent |
83 P. : |
Other physical details |
charts , facsimiles , photoghrphs ; |
Dimensions |
25cm |
502 ## - DISSERTATION NOTE |
Dissertation note |
Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontics |
520 ## - SUMMARY, ETC. |
Summary, etc. |
Statement of problem: Regarding implant placement and its exposure to the oral environment bone usually under-goes resorption and remodeling known as saucerization.The amount of bone resorption is one of the most deciding factors for the success of the dental implant.Stresses transmitted through the implant-abutment complex to the implant surrounding and supporting structures were claimed to the induce bone resorption. Increased transmitted stresses and exceeding the biological tolerance consequently affect the implant longevity and success. purpose: to evaluate the effect of platform switching when using implant supported fixed partial denture on the stresses transmitted to implant supporting structure and the fracture resistance of abutment fixed partial denture assembly material and methods: In vitro study performed using one implant system. Fixture platform diameter 4.7mm and two different abutment sizes, matching platform abutments 4.7mm diameter (group A) and platform switched abutments 3.5mm diameter (group B).Twenty implants were placed in epoxy resin cast, ten for each group and five porcelain fused to metal fixed prosthesis for each group. Both groups were subjected to 100 and 200 N using universal testing machine and strain gauges to measure strain. results: Under 100 & 200 N load; matching plat form abutments showed statistically significantly higher mean stresses induced at all axial surfaces of the implants than platform switched abutments. No significant difference in the fracture resistance of abutments fixed prosthesis assembly between both groups.conclusions: At 100N and 200N platform switching might decrease the amount of stresses transmitted to implant supporting structures and thus, decrease the crestal bone resorption around the fixture neck.The platform switching technique might have no effect on the fracture resistance of abutments and their corresponding fixed partial denture |
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE |
Additional physical form available note |
Issued also as CD |
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Dental implants |
653 #4 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
Implant supported fixed partial denture |
653 #4 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
Platform switching |
653 #4 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
Stresses transmitted |
700 0# - ADDED ENTRY--PERSONAL NAME |
Personal name |
Ahmed Hassanien Khalil , |
Relator term |
|
700 0# - ADDED ENTRY--PERSONAL NAME |
Personal name |
Zeinab Nabil Emam , |
Relator term |
|
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) |
Cataloger |
Nazla |
Reviser |
Revisor |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) |
Cataloger |
Shimaa |
Reviser |
Cataloger |
942 ## - ADDED ENTRY ELEMENTS (KOHA) |
Source of classification or shelving scheme |
Dewey Decimal Classification |
Koha item type |
Thesis |