MARC details
000 -LEADER |
fixed length control field |
03032cam a2200337 a 4500 |
003 - CONTROL NUMBER IDENTIFIER |
control field |
EG-GiCUC |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
fixed length control field |
220226s2021 ua dh f m 000 0 eng d |
040 ## - CATALOGING SOURCE |
Original cataloging agency |
EG-GiCUC |
Language of cataloging |
eng |
Transcribing agency |
EG-GiCUC |
041 0# - LANGUAGE CODE |
Language code of text/sound track or separate title |
eng |
049 ## - LOCAL HOLDINGS (OCLC) |
Holding library |
Deposite |
097 ## - Thesis Degree |
Thesis Level |
Ph.D |
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) |
Classification number |
Cai01.11.01.Ph.D.2021.Ah.H |
100 0# - MAIN ENTRY--PERSONAL NAME |
Personal name |
Ahmed Salah Abdelazeem Elsayed |
245 10 - TITLE STATEMENT |
Title |
Hemodynamic monitoring and correlation between electrical cardiometry and esophageal doppler in patients undergoing major abdominal surgery / |
Statement of responsibility, etc. |
Ahmed Salah Abdelazeem Elsayed ; Suervised Tarek Abdelhalium Kaddah , Abla Elhadedy , Shady Rady Abdallah |
246 15 - VARYING FORM OF TITLE |
Title proper/short title |
مراقبة الدورة الدموية و الارتباط بين جهاز القياس الكهربائى لقوة القلب و دوبلر المرئ فى المرضى الذين يخضعون لجراحات البطن الكبرى |
260 ## - PUBLICATION, DISTRIBUTION, ETC. |
Place of publication, distribution, etc. |
Cairo : |
Name of publisher, distributor, etc. |
Ahmed Salah Abdelazeem Elsayed , |
Date of publication, distribution, etc. |
2021 |
300 ## - PHYSICAL DESCRIPTION |
Extent |
91 P. : |
Other physical details |
charts , facsimiles ; |
Dimensions |
25cm |
502 ## - DISSERTATION NOTE |
Dissertation note |
Thesis (Ph.D.) - Cairo University - Faculty of Medicine - Department of Anesthesia |
520 ## - SUMMARY, ETC. |
Summary, etc. |
Objectives: The aim of this study is to correlate hemodynamic monitoring between noninvasive Electrical Cardiometry (EC) and minimally invasive Esophageal Doppler(ED) in patients undergoing major abdominal surgery. Patients and Methods: The research was conducted on thirty five adult patients, ASA II or III, undergoing major abdominal surgery. Patients were allocated into one group, with Esophageal Doppler and Electrical Cardiometry attached on the same patient. parameters measured were hemodynamic parameters (blood pressure, heart rate, cardiac output, cardiac index.Stroke volume, stroke volume index, systemic vascular resistance and oxygen delivery index). Results: Comparison of cardiac output (CO) with ICON and ED.The ICON mean value range from 5.6 to 6.2 l/min and ED mean value range from 5.7 to 7.6 l/min with non-significant difference between the two methods in all times.The precision for the ICON was measured to be ranged from 15.19 to 17.99% and the precision for ED was ranged from 13.39 to 17.08%. A 15% change of ED values were examined and the sensitivity and specificity of these values to detect an acute change in ICON was calculated and showed that it was highly sensitive 72.6% but low specific 30.9% for acute changes in CO with AUC 0.505. Conclusion: The agreement between CO measured by EC and ED is acceptable. Both were able to monitor trend changes and guide fluid administration in the operation theatre. The EC is as accurate as ED in measuring hemodynamics during major abdominal surgery |
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE |
Additional physical form available note |
Issued also as CD |
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Hemodynamic monitoring |
653 ## - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
Abdominal surgery |
653 ## - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
Electrical cardiometry |
653 ## - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
Esophageal doppler |
700 0# - ADDED ENTRY--PERSONAL NAME |
Personal name |
Abla Elhadedy , |
Relator term |
|
700 0# - ADDED ENTRY--PERSONAL NAME |
Personal name |
Shady Rady Abdallah , |
Relator term |
|
700 0# - ADDED ENTRY--PERSONAL NAME |
Personal name |
Tarek Abdelhalium Kaddah , |
Relator term |
|
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) |
Cataloger |
Nazla |
Reviser |
Revisor |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) |
Cataloger |
Shimaa |
Reviser |
Cataloger |
942 ## - ADDED ENTRY ELEMENTS (KOHA) |
Source of classification or shelving scheme |
Dewey Decimal Classification |
Koha item type |
Thesis |