Predictability of teeth positions during complete denture fabrication using rapid prototyping technology compared to conventional fabrication method : (Record no. 84431)
[ view plain ]
000 -LEADER | |
---|---|
fixed length control field | 02933nam a2200349 a 4500 |
003 - CONTROL NUMBER IDENTIFIER | |
control field | EG-GiCUC |
005 - DATE AND TIME OF LATEST TRANSACTION | |
control field | 20250223032927.0 |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
fixed length control field | 220308s2021 ua dh f m 000 0 eng d |
040 ## - CATALOGING SOURCE | |
Original cataloging agency | EG-GiCUC |
Language of cataloging | eng |
Transcribing agency | EG-GiCUC |
041 0# - LANGUAGE CODE | |
Language code of text/sound track or separate title | eng |
049 ## - LOCAL HOLDINGS (OCLC) | |
Holding library | Deposite |
097 ## - Thesis Degree | |
Thesis Level | M.Sc |
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) | |
Classification number | Cai01.09.09.M.Sc.2021.Em.P |
100 0# - MAIN ENTRY--PERSONAL NAME | |
Personal name | Eman Reda Abdalmouty |
245 10 - TITLE STATEMENT | |
Title | Predictability of teeth positions during complete denture fabrication using rapid prototyping technology compared to conventional fabrication method : |
Remainder of title | an in vitro study / |
Statement of responsibility, etc. | Eman Reda Abdalmouty ; Supervised Ashraf Abdelmoneam Amer , Reham Bassuni Osman |
246 15 - VARYING FORM OF TITLE | |
Title proper/short title | توقعية مواضع الاسنان خلال تصنيع الطقم الكامل باستخدام تقنية التصنيع السريع مقارنة بالطريقة التقليدية للتصنيع : |
Remainder of title | دراسة معملية |
260 ## - PUBLICATION, DISTRIBUTION, ETC. | |
Place of publication, distribution, etc. | Cairo : |
Name of publisher, distributor, etc. | Eman Reda Abdalmouty , |
Date of publication, distribution, etc. | 2021 |
300 ## - PHYSICAL DESCRIPTION | |
Extent | 129 P. : |
Other physical details | charts , facsimiles ; |
Dimensions | 25cm |
502 ## - DISSERTATION NOTE | |
Dissertation note | Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontics |
520 ## - SUMMARY, ETC. | |
Summary, etc. | Aim: The purpose of this study was to compare the predictability of teeth positions during complete dentures fabrication through rapid prototyping technology and conventional fabrication method. Methodology : 12 dentures (6 upper and 6 lower) were fabricated using Liquid Crystal Display (LCD) rapid prototyping technology. The same models were used to fabricate another 12 dentures (6 upper and 6 lower) by the conventional compression flask technique. A structured light scanner was used to digitize the trial denture base of the compression dentures group just before processing, as well as the fabricated dentures by LCD technique.The pre-processing and post-processing scan files of each denture were superimposed using 3D-surface matching software. Measurements were made at 30 locations, allowing evaluation of denture tooth movement in occlusal direction.The use of mean and standard error values was used to assess occlusal accuracy. Data were explored for normality using Kolmogorov-Smirnov and Shapiro-Wilk tests, data showed parametric (normal) distribution. Paired sample t-test was used to compare the results between two groups in related samples. (a=.05). Results: The results showed higher mean value for occlusal teeth movement in the conventional group compared to the rapid prototyping counterpart. There was a statistically significant difference between two groups where (P<0.001) |
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE | |
Additional physical form available note | Issued also as CD |
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
Topical term or geographic name entry element | Prosthodontics Dontics |
653 ## - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Fabrication method |
653 ## - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Prototyping technology |
653 ## - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Teeth positions during |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Ashraf Abdelmoneam Amer , |
Relator term | |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Reham Bassuni Osman , |
Relator term | |
856 ## - ELECTRONIC LOCATION AND ACCESS | |
Uniform Resource Identifier | <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a> |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) | |
Cataloger | Shimaa |
Reviser | Cataloger |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) | |
Reviser | Revisor |
942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
Source of classification or shelving scheme | Dewey Decimal Classification |
Koha item type | Thesis |
Source of classification or shelving scheme | Not for loan | Home library | Current library | Date acquired | Full call number | Barcode | Date last seen | Koha item type | Copy number |
---|---|---|---|---|---|---|---|---|---|
Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | قاعة الرسائل الجامعية - الدور الاول | 11.02.2024 | Cai01.09.09.M.Sc.2021.Em.P | 01010110085538000 | 22.09.2023 | Thesis | ||
Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | مخـــزن الرســائل الجـــامعية - البدروم | 11.02.2024 | Cai01.09.09.M.Sc.2021.Em.P | 01020110085538000 | 22.09.2023 | CD - Rom | 85538.CD |