header

Impact Of Corona Ring On The Electric Field Distribution Of High Voltage Polymeric Insulators / (Record no. 84756)

MARC details
000 -LEADER
fixed length control field 02043nam a2200337 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223032936.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 220824s2022 ua dh f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.13.07.M.Sc.2022.Es.I
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Esraa Aziz Mohamed Hammad
245 10 - TITLE STATEMENT
Title Impact Of Corona Ring On The Electric Field Distribution Of High Voltage Polymeric Insulators /
Statement of responsibility, etc. Esraa Aziz Mohamed Hammad ; Supervised Osama E. Gouda
246 15 - VARYING FORM OF TITLE
Title proper/short title تأثير حلقة الهالة على توزيع المجال الكهربى لعازلات الجهد العالى البوليمرية
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Esraa Aziz Mohamed Hammad ,
Date of publication, distribution, etc. 2022
300 ## - PHYSICAL DESCRIPTION
Extent 78 P . :
Other physical details charts,facsmilies ;
Dimensions 30cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Engineering - Department of Electrical Power and Machines
520 ## - SUMMARY, ETC.
Summary, etc. The study included optimize the grading ring to reduce the electric field on 220 kV polymer suspension insulator in electrostatic physics by COMSOL Multi-Physics Program after drawing it on Auto CAD 2D programme finally reached to the optimum case of electric field when it was clean, then pollution was added to show effect of pollution on electric field distribution, the pollution was water drops with different shapes or cases, also conductivity studied to prove no changing on electric field in electrostatic physics. Therefore, the optimum case was changed after adding pollution on insulator surface to prove the pollution is effect on the electric field distribution then shown the optimum three cases when the insulator was clean and the optimum three cases when it was polluted
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element high voltage
653 ## - INDEX TERM--UNCONTROLLED
Uncontrolled term Corona ring
653 ## - INDEX TERM--UNCONTROLLED
Uncontrolled term electric field
653 ## - INDEX TERM--UNCONTROLLED
Uncontrolled term electric potential
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Osama E. Gouda ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Amira
Reviser Cataloger
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Reviser Revisor
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.13.07.M.Sc.2022.Es.I 01010110085685000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.13.07.M.Sc.2022.Es.I 01020110085685000 22.09.2023 CD - Rom 85685.CD