Patient Satisfaction And Adaptational Accuracy Of Conventional Versus Virtually Fabricated Ear Prosthesis In Patients With Auricular Defects: A Randomized Controlled Trial / (Record no. 84786)
[ view plain ]
000 -LEADER | |
---|---|
fixed length control field | 03811nam a2200361 a 4500 |
003 - CONTROL NUMBER IDENTIFIER | |
control field | EG-GiCUC |
005 - DATE AND TIME OF LATEST TRANSACTION | |
control field | 20250223032937.0 |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
fixed length control field | 220911s2021 ua dho f m 000 0 eng d |
040 ## - CATALOGING SOURCE | |
Original cataloging agency | EG-GiCUC |
Language of cataloging | eng |
Transcribing agency | EG-GiCUC |
041 0# - LANGUAGE CODE | |
Language code of text/sound track or separate title | eng |
049 ## - LOCAL HOLDINGS (OCLC) | |
Holding library | Deposite |
097 ## - Thesis Degree | |
Thesis Level | M.Sc |
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) | |
Classification number | Cai01.09.09.M.Sc.2021.Fa.P |
100 0# - MAIN ENTRY--PERSONAL NAME | |
Personal name | Fatma Mohyeldeen Abdelhameed Hamed |
245 10 - TITLE STATEMENT | |
Title | Patient Satisfaction And Adaptational Accuracy Of Conventional Versus Virtually Fabricated Ear Prosthesis In Patients With Auricular Defects: A Randomized Controlled Trial / |
Statement of responsibility, etc. | Fatma Mohyeldeen Abdelhameed Hamed ; Supervised Amal Rekaby Taha , Mohamed Amr ElKhashab , Sara Fikry Elshafei |
246 15 - VARYING FORM OF TITLE | |
Title proper/short title | محاولة اكلينيكية عشوائية : |
Remainder of title | رضا المريض ودقة التطبع للاستعاضة الأذنية المصنعة تقليدياً مقابل المصنعة افتراضياً فى المرضى الذين يعانون من عيبوب أذنىة |
260 ## - PUBLICATION, DISTRIBUTION, ETC. | |
Place of publication, distribution, etc. | Cairo : |
Name of publisher, distributor, etc. | Fatma Mohyeldeen Abdelhameed Hamed , |
Date of publication, distribution, etc. | 2021 |
300 ## - PHYSICAL DESCRIPTION | |
Extent | 191 P . : |
Other physical details | charts , facsimiles , photographs ; |
Dimensions | 25cm |
502 ## - DISSERTATION NOTE | |
Dissertation note | Thesis (M.Sc.) - Cairo University - Faculty of Oral and dental medicine - Department of Prosthodontics |
520 ## - SUMMARY, ETC. | |
Summary, etc. | This study was conducted to compare virtually fabricated ear prosthesis to the conventional prosthesis, concerning patient satisfaction and adaptation in patients with auricular defects. Methodology: 15 patients were recruited for auricular prosthetic reconstruction; 5 with bilateral defects and 10 with unilateral defects, total of 20 prostheses were fabricated. Preoperative data was collected including personal and medical history, plain photographs and CT scans. Pre-operative prosthetic and implant planning was carried out and surgical stent was fabricated. Three endosseous implants were placed in a two-stage surgical technique. Patients were assigned into two groups with allocation ratio 1:1. In control group, Implant level impression was recorded and a stone model with lab analogues was cast for the defect site. In intervention group, CT scanning was done for the full head and optical scanning was done to the defect site with scan bodies screwed to the implants. Using Bluesky and Exocad softwares a model of the defect site with implant analogues was planned and printed using SLA printing technology. For both groups, bar-clip attachment system was fabricated. to retain the silicone prostheses. For primary outcome assessment, patients were allowed to answer a 17 items questionnaire, each question was given a score from 1-5, total score was recorded for each patient to assess total satisfaction. For the secondary outcome assessment, acrylic ear models were fabricated. In the control group, waxing up of the ear was done on the stone cast followed by flasking, wax elimination, packing of heat cured acrylic resin and curing. In the intervention group, ear model was planned for using Meshmixer and Exocad soft wares to produce ear model with abutment extensions in relation to the implant positions. A placement jig was done for ear models of both groups and adaptaional accuracy was measured on the patient using silicon replica technique. The silicone replica was sectioned into 12 sections and the gap, represented in light consistency polyvinyl siloxane impression material was measured using digital microscope |
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE | |
Additional physical form available note | Issued also as CD |
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
Topical term or geographic name entry element | ct |
653 ## - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Auricular prosthesis |
653 ## - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | computed tomography |
653 ## - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | patient satisfaction |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Amal Rekaby Taha , |
Relator term | |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Mohamed Amr ElKhashab , |
Relator term | |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Sara Fikry Elshafei , |
Relator term | |
856 ## - ELECTRONIC LOCATION AND ACCESS | |
Uniform Resource Identifier | <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a> |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) | |
Cataloger | Amira |
Reviser | Cataloger |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) | |
Reviser | Revisor |
942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
Source of classification or shelving scheme | Dewey Decimal Classification |
Koha item type | Thesis |
Source of classification or shelving scheme | Not for loan | Home library | Current library | Date acquired | Full call number | Barcode | Date last seen | Koha item type | Copy number |
---|---|---|---|---|---|---|---|---|---|
Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | قاعة الرسائل الجامعية - الدور الاول | 11.02.2024 | Cai01.09.09.M.Sc.2021.Fa.P | 01010110085711000 | 22.09.2023 | Thesis | ||
Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | مخـــزن الرســائل الجـــامعية - البدروم | 11.02.2024 | Cai01.09.09.M.Sc.2021.Fa.P | 01020110085711000 | 22.09.2023 | CD - Rom | 85711.CD |