Evaluation of periodontal health of the abutment teeth in partial dentures made of Injection molded PEEK framework versus cobalt chromium framework in mandibular Kennedy class I edentulous cases : (Record no. 84836)
[ view plain ]
000 -LEADER | |
---|---|
fixed length control field | 03744nam a2200301 a 4500 |
003 - CONTROL NUMBER IDENTIFIER | |
control field | EG-GiCUC |
005 - DATE AND TIME OF LATEST TRANSACTION | |
control field | 20250223032938.0 |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
fixed length control field | 220926s2021 ua dho f m 000 0 eng d |
040 ## - CATALOGING SOURCE | |
Original cataloging agency | EG-GiCUC |
Language of cataloging | eng |
Transcribing agency | EG-GiCUC |
041 0# - LANGUAGE CODE | |
Language code of text/sound track or separate title | eng |
049 ## - LOCAL HOLDINGS (OCLC) | |
Holding library | Deposite |
097 ## - Thesis Degree | |
Thesis Level | M.Sc |
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) | |
Classification number | Cai01.09.09.M.Sc.2021.Ah.E |
100 0# - MAIN ENTRY--PERSONAL NAME | |
Personal name | Ahmed Hefny Zidan |
245 10 - TITLE STATEMENT | |
Title | Evaluation of periodontal health of the abutment teeth in partial dentures made of Injection molded PEEK framework versus cobalt chromium framework in mandibular Kennedy class I edentulous cases : |
Remainder of title | A randomized clinical trial / |
Statement of responsibility, etc. | Ahmed Hefny Zidan ; Supervised Amal Rekaby Taha , Nada Sherin |
246 15 - VARYING FORM OF TITLE | |
Title proper/short title | {uFEA9}{uFEAD}{uFE8D}{uFEB3}{uFE94} {uFEB3}{uFEAE}{uFEF3}{uFEAE}{uFEF3}{uFE94} {uFECB}{uFEB8}{uFEEE}{uFE8D}{uFE8B}{uFEF4}{uFE94} : |
Remainder of title | {uFED3}{uFEF2} {uFEA3}{uFE8E}{uFEFB}{uFE95} {uFEDB}{uFEF4}{uFEE8}{uFEAA}{uFEF1} {uFE8D}{uFEDF}{uFE98}{uFED8}{uFEB4}{uFEF4}{uFEE2} {uFE8D}{uFEFB}{uFEED}{uFEDD} Chromium Cobalt والثاني من مادة PEEKتقييم الفارق في صحة الانسجة الداعمة لاسنان بين نوعين من {uئإ٨ؤ}{uئإؤئ}{uئإ٩٨}{uئإءإ}{uئإؤآ}{uئإئ٤}{uئإ٩٢}{uئإ٨إ}{uئإ٩٥} {uئإ٨ؤ}{uئإؤئ}{uئإإ٤}{uئإ٩٨}{uئإء٤}{uئإءإ}{uئإؤآ}{uئإ٩٤} {uئإ٨ؤ}{uئإئآ}{uئإإؤ}{uئإؤؤ} {uئإإ٣}{uئإآأ}{uئإإ٨}{uئإأء} {uئإإ٣}{uئإإ٦} {uئإ٨ؤ}{uئإؤئ}{uئإآأ}{uئإ٩٢}{uئإ٩٤} {uئإ٨ؤ}{uئإؤئ}{uئإإ٤}{uئإء٤}{uئإؤ٨}{uئإإإ}{uئإإ٧}{uئإ٩٤} {uئإإ٣}{uئإإ٦} {uئإإ٣}{uئإ٨إ}{uئإء٩}{uئإ٩٣} |
260 ## - PUBLICATION, DISTRIBUTION, ETC. | |
Place of publication, distribution, etc. | Cairo : |
Name of publisher, distributor, etc. | Ahmed Hefny Zidan , |
Date of publication, distribution, etc. | 2021 |
300 ## - PHYSICAL DESCRIPTION | |
Extent | 119 P . : |
Other physical details | charts , facsimiles , photographs ; |
Dimensions | 25cm |
502 ## - DISSERTATION NOTE | |
Dissertation note | Thesis (M.Sc.) - Cairo University - Faculty of Oral and dental medicine - Department of Prosthodontics |
520 ## - SUMMARY, ETC. | |
Summary, etc. | Aim: The objective of this study was to evaluate the periodontal health of the abutment teeth in partial dentures made of Injection molded PEEK framework in compared with cobalt chromium framework in mandibular kennedy class I free end saddle edentulous cases. Methodology: Two groups of patients representing Kennedy class I with last standing premolar teeth bilaterally. A conventional cobalt chromium RPD was constructed for each patient in the control group, while PEEK RPD (utilizing injection technology) was constructed for each patient in the intervention group. Periotest used to evaluate the periodontal health of the abutment teeth at the time of delivery and after 3 and 6 months.Results: In the control group, there was no significant difference between values measured at different intervals. The highest value was measured after 3 months, followed by 1 month, while the lowest value was measured at baseline. And the same was for the intervention group as there was no significant difference between values measured at different intervals. The highest value was measured after 1 month, followed by 3 months, while the lowest value was measured at baseline. Comparing the two groups together, there was no statistically significant difference between them.Conclusions: There was an increase in abutment teeth mobility for both groups from zero to three months but finally both RPD frameworks offered acceptable degree of periodontal health preservation. The injected PEEK RPD frameworks provided less degree of abutment teeth mobility with better preservation of their periodontal health |
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE | |
Additional physical form available note | Issued also as CD |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Amal Rekaby Taha , |
Relator term | |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Nada Sherin , |
Relator term | |
856 ## - ELECTRONIC LOCATION AND ACCESS | |
Uniform Resource Identifier | <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a> |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) | |
Cataloger | Amira |
Reviser | Cataloger |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) | |
Reviser | Revisor |
942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
Source of classification or shelving scheme | Dewey Decimal Classification |
Koha item type | Thesis |
Source of classification or shelving scheme | Not for loan | Home library | Current library | Date acquired | Full call number | Barcode | Date last seen | Koha item type | Copy number |
---|---|---|---|---|---|---|---|---|---|
Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | قاعة الرسائل الجامعية - الدور الاول | 11.02.2024 | Cai01.09.09.M.Sc.2021.Ah.E | 01010110085743000 | 22.09.2023 | Thesis | ||
Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | مخـــزن الرســائل الجـــامعية - البدروم | 11.02.2024 | Cai01.09.09.M.Sc.2021.Ah.E | 01020110085743000 | 22.09.2023 | CD - Rom | 85743.CD |