header

Remote continuous monitoring for the ground grid resistance / (Record no. 8703)

MARC details
000 -LEADER
fixed length control field 018290000a22003250004500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GICUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223025235.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 061106s2004 ua a f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GICUC
Language of cataloging eng
Transcribing agency EG-GICUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title Eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level Ph.D
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.13.07.Ph.D.2004.Mo.R
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Mohamed Gamal_ElDin Hassan Abdallah
245 10 - TITLE STATEMENT
Title Remote continuous monitoring for the ground grid resistance /
Statement of responsibility, etc. Mohamed Gamal_ElDin Hassan Abdallah ; Supervised Essam AbueLDahab , Mahmoud Gilani , Mohamed ElHadidi
246 15 - VARYING FORM OF TITLE
Title proper/short title المراقبة المستمرة عن بعد لمقاومة شبكات التاريض
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Mohamed Gamal_ElDin Hassan Abdallah ,
Date of publication, distribution, etc. 2004
300 ## - PHYSICAL DESCRIPTION
Extent 157p :
Other physical details ill ;
Dimensions 30cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (PH.D.) - Cairo University - Faculty of Engineering - Department of Electrical Power and Machines
520 ## - SUMMARY, ETC.
Summary, etc. Earthing plays an important role in the reliability of electrical power systemsAs it helps in ensuring the stability of the voltage level , it is common practice to connect the system to ground at suitable pointsSuch a connection will absorb sufficient current in the event of faultMaintaining variation in the ground grid resistance (Rg) within extremely tight limits is of utmost importance , as substantial variation leads to a potentially large variation in the ground step - voltage in the proximity of operational equipment , and could also increase the touch voltage on the equipment casing
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Continuos monitoring
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Essam AbueLDahab ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Mahmoud Gilani ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Mohamed ElHadidi ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Aml
Reviser Cataloger
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Esam
Reviser Revisor
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.13.07.Ph.D.2004.Mo.R 01010110043398000 22.09.2023 Thesis
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.13.07.Ph.D.2004.Mo.R 01020110043398000 22.09.2023 CD - Rom