Flow , thermal patterns and moisture distributions in ventilated archaeological tombs , valley of kings , Luxor / Osama Mohamed Salama ; Supervised Essam E.Khalil
Language: Eng Publication details: Cairo : Osama Mohamed Salama Abdelaziz , 2008Description: 131P. : charts ; 30cmOther title:- السريان ونهج الحرارة وتوزيعات الرطوبة فى مقابر وادى الملوك الاثرية المهواه بالاقصر [Added title page title]
- Issued also as CD
Item type | Current library | Home library | Call number | Copy number | Status | Barcode | |
---|---|---|---|---|---|---|---|
![]() |
قاعة الرسائل الجامعية - الدور الاول | المكتبة المركزبة الجديدة - جامعة القاهرة | Cai01.13.11.M.Sc.2008.Os.F (Browse shelf(Opens below)) | Not for loan | 01010110049801000 | ||
![]() |
مخـــزن الرســائل الجـــامعية - البدروم | المكتبة المركزبة الجديدة - جامعة القاهرة | Cai01.13.11.M.Sc.2008.Os.F (Browse shelf(Opens below)) | 49801.CD | Not for loan | 01020110049801000 |
Browsing المكتبة المركزبة الجديدة - جامعة القاهرة shelves Close shelf browser (Hides shelf browser)
No cover image available | No cover image available | No cover image available | No cover image available | No cover image available | No cover image available | No cover image available | ||
Cai01.13.11.M.Sc.2008.Om.F Flow and conbustion in cylindrical furnaces at different operating conditions / | Cai01.13.11.M.Sc.2008.Om.F Flow and conbustion in cylindrical furnaces at different operating conditions / | Cai01.13.11.M.Sc.2008.Os.F Flow , thermal patterns and moisture distributions in ventilated archaeological tombs , valley of kings , Luxor / | Cai01.13.11.M.Sc.2008.Os.F Flow , thermal patterns and moisture distributions in ventilated archaeological tombs , valley of kings , Luxor / | Cai01.13.11.M.Sc.2009.Ah.B Building stairwell pressurization system as a part of smoke management systems / | Cai01.13.11.M.Sc.2009.Ah.B Building stairwell pressurization system as a part of smoke management systems / | Cai01.13.11.M.Sc.2009.Ah.F Feasibility of fuzzy logic control for steam turbine control systems / |
Thesis (M.Sc.) - Cairo University - Faculty Of Engineering - Department Of Mechanical Power Engineering
Theme of this research is to study the mechanical ventilation systems effect on airflow including temperature and relative humidity distribution inside four tombs namely KVI , KV2 , KVI3 and KVI5 , the study is carried out using computational fluid dynamics CFD