header
Local cover image
Local cover image
Image from OpenLibrary

Evaluating the Effect of Surface Treatment of Zirconia Ceramics with Erbium Family Lasers on Bond Strength to Resin Cement : An in vitro study / By Mohamed Nasr Mohamed Elsayed Abu El Saud; Supervisors Committee Prof. Dr. Ali Saafan, Prof. Dr. Nagy Abdul Samee, Prof. Dr. Tarek Abdelhamid Elsayed, Dr. Sahar Mohamed Mokhtar.

By: Contributor(s): Material type: TextTextLanguage: English Summary language: English Spoken language: Arabic Producer: 2022Description: 131 pages : illustrations ; 25 cm. + CDContent type:
  • text
Media type:
  • Unmediated
Carrier type:
  • volume
Other title:
  • تقييم تاثير نوعين من ليزر الاربيم فى معالجة سطح الزيركون على قوة رابطة الشد للاصق الريزن دراسة معملية [Added title page title]
Subject(s): DDC classification:
  • 617.6
Available additional physical forms:
  • Issued also as CD
Dissertation note: Thesis (Ph.D)-Cairo University, 2022. Summary: According to surface roughness the results of the present study we rejected the null hypothesis that Erbium lasers irradiation would roughen the surface of zirconia identical as sand blast. The later still the best treatment method this result came in agreement with many studies air abrasion is the most effective surface treatment method than the application of Er: YAG lasers and it has been shown that irradiation of Y-TZP ceramic surfaces with Er: YAG lasers did not increase the surface roughness significantlySummary: الهدف من هذه الدراسة هو مقارنة تأثير الليزرالأربيم ياج والأربيم كورميوم ( على تخشين سطح الزيركون وكذلك تأتير النبضة الطويلة والقصيرة ومدة المعالجة على تخشين سطح الزيركون مقارنة بالطريقة التقليدية وهى التخشين بالرمالة ونتائج هذه الدراسة أسفرت عن أن النبضة أن النبضة طويلة أو قصيرة لا تؤثر على التخشين لدرجة أن نقول أنها أعلى من الطريقة التقليدية ووجدنا أيضا أن كلما زادت مدة المعالجة بالليزر يقل التخشين ولكن فى النهاية إرتباط الاصق على الزيركون سواء المعالج بالليزر أو المعالج بالطريقة التقليدية لا يعتبر مؤثر في هذه النقطة وعندما قارنا قوة هذه الرابطة في إختبار قوة الشد وجدنا أن كل المعالجات أسفرت عن نفس النتيجة
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Home library Call number Status Barcode
Thesis Thesis قاعة الرسائل الجامعية - الدور الاول المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.24.03.Ph.D.2022.Mo.E (Browse shelf(Opens below)) Not for loan 01010110088252000

Thesis (Ph.D)-Cairo University, 2022.

Bibliography: pages 99-131.

According to surface roughness the results of the present study we rejected the null hypothesis that Erbium lasers irradiation would roughen the surface of zirconia identical as sand blast. The later still the best treatment method this result came in agreement with many studies air abrasion is the most effective surface treatment method than the application of Er: YAG lasers and it has been shown that irradiation of Y-TZP ceramic surfaces with Er: YAG lasers did not increase the surface roughness significantly

الهدف من هذه الدراسة هو مقارنة تأثير الليزرالأربيم ياج والأربيم كورميوم ( على تخشين سطح الزيركون وكذلك تأتير النبضة الطويلة والقصيرة ومدة المعالجة على تخشين سطح الزيركون مقارنة بالطريقة التقليدية وهى التخشين بالرمالة ونتائج هذه الدراسة أسفرت عن أن النبضة أن النبضة طويلة أو قصيرة لا تؤثر على التخشين لدرجة أن نقول أنها أعلى من الطريقة التقليدية ووجدنا أيضا أن كلما زادت مدة المعالجة بالليزر يقل التخشين ولكن فى النهاية إرتباط الاصق على الزيركون سواء المعالج بالليزر أو المعالج بالطريقة التقليدية لا يعتبر مؤثر في هذه النقطة وعندما قارنا قوة هذه الرابطة في إختبار قوة الشد وجدنا أن كل المعالجات أسفرت عن نفس النتيجة

Issued also as CD

Text in English and abstract in Arabic & English.

There are no comments on this title.

to post a comment.

Click on an image to view it in the image viewer

Local cover image