Assessment Of Seismic Retrofitting For Soft-Story Buildings Using Gapped Inclined Brace System / By Mohamed Adel Tohamy Ahmed ; Under the Supervision of Prof. Dr. Adel Y. Akl.

By: Contributor(s): Material type: TextTextLanguage: English Summary language: English Spoken language: Arabic Producer: 2023Description: 199 pages : illustrations ; 30 cm. + CDContent type:
  • text
Media type:
  • Unmediated
Carrier type:
  • volume
Other title:
  • تقييم التدعيم المضاد للزلازل للمباني ذات الطوابق المرنة باستخدام نظام الشكالات المائلة ذات الفجوة [Added title page title]
Subject(s): DDC classification:
  • 624.1
Available additional physical forms:
  • Issued also as CD
Dissertation note: Thesis (Ph.D)-Cairo University, 2023. Summary: Gap-Inclined-Brace (GIB) system is a new retrofit technique that provides more ductility and less P-delta effect for soft-story buildings under seismic loads. The effect of the eccentricity between GIB and retrofitted column during installation on the retrofitting system efficiency is studied in this thesis. Moreover, the determination method of GIB properties is adjusted to reduce the effect of GIB eccentricity. In addition, the seismic response of retrofitted mid-rise buildings with different heights considering soft-story at various heights has been studied. Numerical investigation has been performed using finite element models for two mid-rise concrete buildings, by considering several locations of soft-story. To achieve that goal, Non-linear static pushover analysis and Non-linear time history analyses using several earthquake records and intensities are performed for each case study scenario before and after retrofitting. The results showed that large GIB eccentricity reduces the ultimate lateral resistance and deformation capacity of the retrofitting systemSummary: الشكالات المائلة ذات الفجوة هي نظام تدعيم مستجد للأدوار المرنة يؤدي لزيادة الممطولية للدور المرن وتقليل تأثير الأفعال من الدرجة الثانية تحت تأثير أحمال الزلازل. في هذا البحث تمت دراسة تأثير الإزاحة بين الشكالات المائلة والعمود المدعم الناتجة من عملية التركيب على كفاءة نظام التدعيم، بالإضافة إلى تعديل طريقة حساب خصائص نظام التدعيم للتقليل من التأثير السلبي للإزاحة على كفاءة النظام. أيضا تمت دراسة استجابة المباني متوسطة الارتفاع ذات الأدوار المرنة تحت تأثير أحمال الزلازل قبل وبعد التدعيم بالنظام المستجد وأنظمة التدعيم التقليدية مع الأخذ في الاعتبار العديد من المتغيرات. تم عمل نماذج حسابية لمبنيين من الخرسانة المسلحة بارتفاعات مختلفة مع الاخذ في الاعتبار مناسيب متنوعة للدور المرن. تم تحليل حالات الدراسة قبل وبعد التدعيم باستخدام التحليل الإستاتيكي الغير خطي بالدفع الجانبي ثم التحليل الديناميكي للسجل الزمني باستخدام عشر قراءات زلزالية وعجلات أرضية قصوى متنوعة. وقد تبين ان الإزاحات الكبرى في نظام التدعيم الناتجة من عملية التركيب تقلل من كفاءته.
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Home library Call number Status Date due Barcode
Thesis Thesis قاعة الرسائل الجامعية - الدور الاول المكتبة المركزبة الجديدة - جامعة القاهرة Cai01 13 05 Ph.D 2023 Mo.A (Browse shelf(Opens below)) Not for loan 01010110088298000

Thesis (Ph.D)-Cairo University, 2023.

Bibliography: pages 155-158.

Gap-Inclined-Brace (GIB) system is a new retrofit technique that provides more
ductility and less P-delta effect for soft-story buildings under seismic loads. The effect
of the eccentricity between GIB and retrofitted column during installation on the
retrofitting system efficiency is studied in this thesis. Moreover, the determination
method of GIB properties is adjusted to reduce the effect of GIB eccentricity. In
addition, the seismic response of retrofitted mid-rise buildings with different heights
considering soft-story at various heights has been studied. Numerical investigation has
been performed using finite element models for two mid-rise concrete buildings, by
considering several locations of soft-story. To achieve that goal, Non-linear static
pushover analysis and Non-linear time history analyses using several earthquake
records and intensities are performed for each case study scenario before and after
retrofitting. The results showed that large GIB eccentricity reduces the ultimate lateral
resistance and deformation capacity of the retrofitting system

الشكالات المائلة ذات الفجوة هي نظام تدعيم مستجد للأدوار المرنة يؤدي لزيادة الممطولية للدور المرن وتقليل تأثير الأفعال من الدرجة الثانية تحت تأثير أحمال الزلازل. في هذا البحث تمت دراسة تأثير الإزاحة بين الشكالات المائلة والعمود المدعم الناتجة من عملية التركيب على كفاءة نظام التدعيم، بالإضافة إلى تعديل طريقة حساب خصائص نظام التدعيم للتقليل من التأثير السلبي للإزاحة على كفاءة النظام. أيضا تمت دراسة استجابة المباني متوسطة الارتفاع ذات الأدوار المرنة تحت تأثير أحمال الزلازل قبل وبعد التدعيم بالنظام المستجد وأنظمة التدعيم التقليدية مع الأخذ في الاعتبار العديد من المتغيرات. تم عمل نماذج حسابية لمبنيين من الخرسانة المسلحة بارتفاعات مختلفة مع الاخذ في الاعتبار مناسيب متنوعة للدور المرن. تم تحليل حالات الدراسة قبل وبعد التدعيم باستخدام التحليل الإستاتيكي الغير خطي بالدفع الجانبي ثم التحليل الديناميكي للسجل الزمني باستخدام عشر قراءات زلزالية وعجلات أرضية قصوى متنوعة. وقد تبين ان الإزاحات الكبرى في نظام التدعيم الناتجة من عملية التركيب تقلل من كفاءته.