header
Image from OpenLibrary

Comparison Of Trunatomy And Xp Endo Shaper On Amount Of Dentin Removal Using Micro-Computed Tomography : In Vitro Study / by Elaf Ali Hassan Rehan ; Supervisors Prof. Dr. Geraldine Mohammed Ahmed, Dr. Radwa Sameeh Emara

By: Contributor(s): Material type: TextTextLanguage: English Summary language: English Spoken language: Arabic Producer: 2023Description: 76 pages : illustrations ; 25 cm. + CDContent type:
  • text
Media type:
  • Unmediated
Carrier type:
  • volume
Other title:
  • مقارنة ما بين تروناتومي فايل واكس بي اندو شيبر على مقدار إزالة العاج باستخدام التصوير المقطعي المحوسب : دراسة معملية [Added title page title]
Subject(s): DDC classification:
  • 617.6
Available additional physical forms:
  • Issued also as CD
Dissertation note: Thesis (M.Sc.)-Cairo University, 2023. Summary: This in vitro study aimed to use micro-computed tomography to evaluate the effectiveness of the TruNatomy versus the XP endo shaper for removing dentin from single-rooted permanent teeth with straight root canals. Method: A total of ninety-eight extracted human single-root teeth were collected and divided into two equal groups; TruNatomy (TRN) and XP endo shaper (XPS). Root canal instrumentation was done according to the manufacturer’s instructions for each NiTi system. Pre- and post- instrumentation images were scanned by using SkyScan 1172 micro-CT scanner at a resolution of 13.73 μm to measure dentin removal, differences in dentin thickness, and percent change in root canal volume. Result: The TruNatomy group and XP endo shaper had no significant difference regarding the amount of removed dentin. Conclusion: Under the limitations of the in vitro study, it can be concluded that; there was no significant difference in post-instrumentation canal volume between TRN and XPS. Also, there was no significant difference in post-instrumentation dentine removal between the TRN versus XPS. Thus both file systems are equally recommended for clinical use as a practice of MIE based on the in-vivo study.Summary: غرض البحث: كان الهدف من هذه الدراسة في المختبر هو استخدام التصوير المقطعي المحوسب لتقييم فعالية تروناتومي واكس بي اندو شيبر لإزالة العاج من أسنان دائمة ذات جذر واحد مع قنوات جذر مستقيمة. طريقه البحث: تم جمع ما مجموعه ثمانية وتسعين من أسنان دائمة ذات جذر واحد مع قنوات جذر مستقيمة المستخرجة وقسمت إلى مجموعتين متساويتين تروناتومي واكس بي اندو شيبر. تم عمل أجهزة قناة الجذر وفقًا لتعليمات الشركات المصنعة لكل نظام نايتاي. تم التقاط الصور قبل وبعد الأجهزة باستخدام باستخدام ماسح ضوئي دقيق من نوع سكاي سكان 1172 بدقة 13.73 µm ميكروميتر لقياس إزالة العاج، والاختلافات في سمك العاج ونسبة التغير في حجم قناة الجذر. النتيجة: لم يكن لمجموعة تروناتومي واكس بي اندو شيبر فرق ملحوظ بين المجموعتين في كمية العاج المزال. الخلاصة: في ظل قيود الدراسة المخبرية، يمكن استنتاج أن: لا يوجد فرق كبير في حجم قناة ما بعد الأجهزة بين تروناتومي واكس بي اندو شيبر أيضًا، ولا يوجد فرق كبير في إزالة العاج بعد الأجهزة بين تروناتومي مقابل اكس بي اندو شيبر وكلا الجهازين فعالان بنفس القدر في كل من حجم القناة وعاج. إزالة، وبالتالي يمكن أن يكون كلا نظامي الملفات موصى به على حد سواء للاستخدام السريري كممارسة تداخل أصغري على أساس الدراسة في الجسم الحي
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Home library Call number Status Date due Barcode
Thesis Thesis قاعة الرسائل الجامعية - الدور الاول المكتبة المركزبة الجديدة - جامعة القاهرة Cai01 09 02 M.Sc 2023 El.C (Browse shelf(Opens below)) Not for loan 01010110088366000

Thesis (M.Sc.)-Cairo University, 2023.

Bibliography: pages 69-74.

This in vitro study aimed to use micro-computed tomography to evaluate the effectiveness of
the TruNatomy versus the XP endo shaper for removing dentin from single-rooted permanent teeth
with straight root canals.
Method: A total of ninety-eight extracted human single-root teeth were collected and divided into
two equal groups; TruNatomy (TRN) and XP endo shaper (XPS). Root canal instrumentation was
done according to the manufacturer’s instructions for each NiTi system. Pre- and post-
instrumentation images were scanned by using SkyScan 1172 micro-CT scanner at a resolution of
13.73 μm to measure dentin removal, differences in dentin thickness, and percent change in root canal
volume.
Result: The TruNatomy group and XP endo shaper had no significant difference regarding the
amount of removed dentin.
Conclusion: Under the limitations of the in vitro study, it can be concluded that; there was no
significant difference in post-instrumentation canal volume between TRN and XPS. Also, there was
no significant difference in post-instrumentation dentine removal between the TRN versus XPS. Thus
both file systems are equally recommended for clinical use as a practice of MIE based on the in-vivo
study.

غرض البحث: كان الهدف من هذه الدراسة في المختبر هو استخدام التصوير المقطعي المحوسب لتقييم فعالية تروناتومي واكس بي اندو شيبر لإزالة العاج من أسنان دائمة ذات جذر واحد مع قنوات جذر مستقيمة.
طريقه البحث: تم جمع ما مجموعه ثمانية وتسعين من أسنان دائمة ذات جذر واحد مع قنوات جذر مستقيمة المستخرجة وقسمت إلى مجموعتين متساويتين تروناتومي واكس بي اندو شيبر. تم عمل أجهزة قناة الجذر وفقًا لتعليمات الشركات المصنعة لكل نظام نايتاي. تم التقاط الصور قبل وبعد الأجهزة باستخدام باستخدام ماسح ضوئي دقيق من نوع سكاي سكان 1172 بدقة 13.73 µm ميكروميتر لقياس إزالة العاج، والاختلافات في سمك العاج ونسبة التغير في حجم قناة الجذر.
النتيجة:
لم يكن لمجموعة تروناتومي واكس بي اندو شيبر فرق ملحوظ بين المجموعتين في كمية العاج المزال.
الخلاصة: في ظل قيود الدراسة المخبرية، يمكن استنتاج أن: لا يوجد فرق كبير في حجم قناة ما بعد الأجهزة بين تروناتومي واكس بي اندو شيبر أيضًا، ولا يوجد فرق كبير في إزالة العاج بعد الأجهزة بين تروناتومي مقابل اكس بي اندو شيبر وكلا الجهازين فعالان بنفس القدر في كل من حجم القناة وعاج. إزالة، وبالتالي يمكن أن يكون كلا نظامي الملفات موصى به على حد سواء للاستخدام السريري كممارسة تداخل أصغري على أساس الدراسة في الجسم الحي

Issued also as CD

Text in English and abstract in Arabic & English.

There are no comments on this title.