header
Image from OpenLibrary

Retention Of A Chrome-Cobalt Versus Peek Telescopic Retainer For An Implant Supported Overdenture : An Invitro-Study / by Khaled Mahmoud El Samanoudy ; Supervisors by Prof. Dr. Iman Abd El Wahab Radi, Dr. Nouran Abd El Nabi

By: Contributor(s): Material type: TextTextLanguage: English Summary language: English, Arabic Producer: 2022Description: 131 pages : illustrations ; 25 cm. + CDContent type:
  • text
Media type:
  • Unmediated
Carrier type:
  • volume
Other title:
  • الابقاء علي الكروم كوبلت مقابل البيك المثبت تلسكوبيا لطقم فوقي مثبت بالزراعة : تجربة في المختبر [Added title page title]
Subject(s): DDC classification:
  • 617.692
Available additional physical forms:
  • Issued also as CD
Dissertation note: Thesis (M.Sc.)-Cairo University, 2022. Summary: The present study was carried out to compare the retention of two groups of frameworks having different types of materials. Both frameworks were used to retain four implant-supported mandibular overdentures. Retention was evaluated using universal testing machine after mechanical aging that was carried out using chewing simulator. The intervention group was the milled PEEK framework group while control group was the milled Co-Cr framework group. One epoxy models of completely edentulous mandible were constructed and prepared to receive four implants in each model. Six frameworks were constructed; three milled Co-Cr frameworks and three milled PEEK frameworks. Then retention values were measured at baseline using universal testing machine and then the models in each group were subjected to different chewing cycles 12500 and 37500 cycles using ROBOTA chewing simulator. Both the milled cobalt-chromium and milled PEEK groups showed a statistically significant decrease in retention when subjected to different cycles. At baseline, Group C recorded (15.552 ± 1.408) while Group P recorded (8.130 ± 0.885). After 12500 cycles (1 month), Group C recorded (14.818 ± 1.286) while Group P recorded (5.667 ± 0.886) and after 37500cycles (3 months), Group C recorded (9.319 ± 1.374), while Group P recorded (4.418 ± 0.844) with P<0.0001. The overall % change in retention recorded (-40.078%) in Group C while it recorded (-48.98%) in Group P. Summary: أجريت هذه الدراسة لمقارنة الكروم الكوبلت المخروط مقابل البيك المخروط المثبت تلسكوبيا لطقم فوقي مثبت - بالزراعه، باستخدام آلة اختبار عالمية بعد التقادم الميكانيكي الذي تم بواسطة جهاز محاكاة المضغ، كانت مجموعة التدخل عبارة عن البيك المخروط مرفق كانت مجموعة التحكم الكروم الكوبلت المخروط ومجموعة محدد المواقع. - تم بناء نموذجان من إيبوكسي للفك السفلي عديم الأسنان تمامًا وتجهيزه لتلقي اربعة غرسات، تم بناء عشرة أطقم مثبتة، ثم تم قياس قيم الاحتفاظ بعد التقادم الميكانيكي، تم جدولة النتائج وتحليلها إحصائيا للوصول إلى النتيجة
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Home library Call number Status Date due Barcode
Thesis Thesis قاعة الرسائل الجامعية - الدور الاول المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.01.09.M.Sc.2022.Kh.R (Browse shelf(Opens below)) Not for loan 01010110088618000
Browsing المكتبة المركزبة الجديدة - جامعة القاهرة shelves Close shelf browser (Hides shelf browser)
No cover image available
No cover image available
No cover image available
No cover image available
No cover image available
No cover image available
No cover image available
Cai01.01.04.03.Ph.D.2022.من.م. مكافحة الجرائم الماسة بنزاهة الوظيفة العامة في التشريع الفلسطيني : دراسة مقارنة / Cai01.01.09..08.M.sc.2020 The Use of Specially Designed Probe Versus Cone- Beam Computerized Tomography in The Measurement of Gingival Thickness Diagnostic Accuracy Study / Cai01.01.09.03.Ph.D.2021.Ra.M. MISWAK VERSUS STANDARD MEASURES TO PREVENT THE INCIDENCE OF CARIES IN YOUNG EGYPTIAN ADULTS: A RANDOMIZED CONTROLLED CLINICAL TRIAL / Cai01.01.09.M.Sc.2022.Kh.R Retention Of A Chrome-Cobalt Versus Peek Telescopic Retainer For An Implant Supported Overdenture : An Invitro-Study / Cai01.01.11.20.Ph.D.2021.Gh.C. Compative Study Between Tumour Excision with Simultanous Endoscopic Third Ventriclostomy and Tumor Excision without Endoscopic Third Ventriculostomy in / Cai01.01.26.03.M.Sc.2022.اب.ب برنامج لتنمية المهارات الحسية وعلاقته بالتماسك المركزي لدى الأطفال ذوي اضطراب طيف الذاتوية مرتفعي الأداء الوظيفي / Cai01.01.26.03M.Sc.2022نر.ف فعالية برنامج نفسي حركى لتنمية الوعى بالجسم لدى الأطفال ذوى اضطراب الذاتوية /

Thesis (M.Sc.)-Cairo University, 2022.

Bibliography: pages 116-131.

The present study was carried out to compare the retention of two groups of frameworks having different types of materials. Both frameworks were used to retain four implant-supported mandibular overdentures. Retention was evaluated using universal testing machine after mechanical aging that was carried out using chewing simulator.
The intervention group was the milled PEEK framework group while control group was the milled Co-Cr framework group.
One epoxy models of completely edentulous mandible were constructed and prepared to receive four implants in each model. Six frameworks were constructed; three milled Co-Cr frameworks and three milled PEEK frameworks. Then retention values were measured at baseline using universal testing machine and then the models in each group were subjected to different chewing cycles 12500 and 37500 cycles using ROBOTA chewing simulator.
Both the milled cobalt-chromium and milled PEEK groups showed a statistically significant decrease in retention when subjected to different cycles. At baseline, Group C recorded (15.552 ± 1.408) while Group P recorded (8.130 ± 0.885). After 12500 cycles (1 month), Group C recorded (14.818 ± 1.286) while Group P recorded (5.667 ± 0.886) and after 37500cycles (3 months), Group C recorded (9.319 ± 1.374), while Group P recorded (4.418 ± 0.844) with P<0.0001.
The overall % change in retention recorded (-40.078%) in Group C while it recorded (-48.98%) in Group P.

أجريت هذه الدراسة لمقارنة الكروم الكوبلت المخروط مقابل البيك المخروط المثبت تلسكوبيا لطقم فوقي مثبت -
بالزراعه، باستخدام آلة اختبار عالمية بعد التقادم الميكانيكي الذي تم بواسطة جهاز محاكاة المضغ، كانت مجموعة التدخل
عبارة عن البيك المخروط مرفق كانت مجموعة التحكم الكروم الكوبلت المخروط ومجموعة محدد المواقع. -
تم بناء نموذجان من إيبوكسي للفك السفلي عديم الأسنان تمامًا وتجهيزه لتلقي اربعة غرسات، تم بناء عشرة أطقم
مثبتة، ثم تم قياس قيم الاحتفاظ بعد التقادم الميكانيكي، تم جدولة النتائج وتحليلها إحصائيا للوصول إلى النتيجة

Issued also as CD

Text in English and abstract in Arabic & English.

There are no comments on this title.

to post a comment.