Numerical investigation of thermal comfort and indoor air quality inside bank / by Abdelrahman Sayed Mohamed Sayed Elhlwaney ; Supervisor Prof. Dr. Mahmoud Fouad, Dr.Ahmed Abou Zaid, Dr.Ahmed Hamed.
Material type:
- text
- Unmediated
- volume
- / اﻟﺘﺤﻘق اﻟﻌددي للراحة الحرارية وجودة الهواء الداﺧﻠﻲ داﺧﻞ اﻟﺒنك [Added title page title]
- 621.402
- Issues also as CD.
Item type | Current library | Home library | Call number | Status | Barcode | |
---|---|---|---|---|---|---|
![]() |
قاعة الرسائل الجامعية - الدور الاول | المكتبة المركزبة الجديدة - جامعة القاهرة | Cai01.13.11.M.Sc.2024.Ab.N (Browse shelf(Opens below)) | Not for loan | 01010110090071000 |
Browsing المكتبة المركزبة الجديدة - جامعة القاهرة shelves Close shelf browser (Hides shelf browser)
No cover image available | No cover image available | No cover image available | No cover image available | No cover image available | No cover image available | No cover image available | ||
Cai01.13.11.M.Sc.2023.Ma.D Development of markov chain-based driving cycles for light-duty vehicles in greater Cairo / | Cai01.13.11.M.Sc.2023.Ma.N Numerical simulation of bidirectional impulse turbines for thermoacoustic engines / | Cai01.13.11.M.Sc.2023.Om.E. Experimental investigation of high-flowrate sensible-only vapor compression air conditioner / | Cai01.13.11.M.Sc.2024.Ab.N Numerical investigation of thermal comfort and indoor air quality inside bank / | Cai01.13.11.M.Sc.2024.Mo.N Numerical investigation of a thermoacoustic flue gas analyzer / | Cai01.13.11.Ph.D.1996.Ab.E Experimental and theoretical study of methods for enhancing condensation heat - transfer around vertical tubes / | Cai01.13.11.Ph.D.1996.Ah.O The oretical and experimental study of ignition characteristics of organic dust behind shock waves / |
Thesis (M.Sc.)-Cairo University, 2024.
Bibliography: pages 112-114.
The present thesis work is concerned primarily with the analysis and simulation of the thermal comfort and indoor air quality in a Bank.
The research is approved available using computational fluid dynamics (CFD) simulation techniques as embedded in the commercially available CFD code (ANSYS 19.2). The CFD showing techniques solved the continuity, momentum, and energy conservation equations in addition to RNG k – ε model equations for turbulence closure. Mesh sizes used in present work is 4.5 million approximately.
يهتم عمل الأطروحة الحالي في المقام الأول بتحليل ومحاكاة الراحة الحرارية وجودة الهواء الداخلي في البنك. تمت الموافقة على البحث المتاح باستخدام تقنيات محاكاة ديناميكيات الموائع الحسابية (CFD) كما هو مضمن في كود CFD المتاح تجاريا (ANSYS 19.2). حلت تقنيات عرض CFD معادلات الاستمرارية والزخم والحفاظ على الطاقة بالإضافة إلى معادلات نموذج RNG k - ε لإغلاق الاضطراب. أحجام الشبكات المستخدمة في العمل الحالي هي 4.5 م