header
Image from OpenLibrary

Internal fit and marginal adaptation of all ceramic implant-supported hybrid abutment crowns to ti-base : in vitro study / by Marwa Wagih Zaki Fouad Fakhr ; Supervisors Prof. Hesham Al Ansary, Dr. Eman Ezzat Youssef Hassanien.

By: Contributor(s): Material type: TextTextLanguage: English Summary language: English, Arabic Producer: 2024Description: 108 pages : illustrations ; 25 cm. + CDContent type:
  • text
Media type:
  • Unmediated
Carrier type:
  • volume
Other title:
  • : تقويم الملائمة الداخلية والتكيف الهامشي بين تيجان السيراميك الهجينة المثبتة على زرع الأسنان وقاعدة التيتانيوم / دراسة في المختبر [Added title page title]
Subject(s): DDC classification:
  • 617.69
Available additional physical forms:
  • Issues also as CD.
Dissertation note: Thesis (M.Sc)-Cairo University, 2023. Summary: Aim: Evaluating the internal fit and marginal adaptation between ultra-translucent multilayered zirconia (UT) and lithium disilicate (LDS) implant-supported hybrid abutment crowns (HACs) and Ti base. Methodology: A total of 24 implant‐supported hybrid abutment crowns on 12 titanium implant analogues were manufactured by a fully digital workflow. The HACs were divided into two equal groups (n=12). Group LDS and group UT HACs. Internal fit and marginal adaptation of the HACs were measured using the replica technique and stereomicroscope, respectively. Then, the results of both groups were statistically analysed. Results: No significant difference was found in the mean internal and marginal gaps between group LDS (43.89 µm ± 8.02 and 94.00 µm ± 6.51, respectively) and group UT (71.62 µm ± 12.56 and 43.77 µm ± 6.00, respectively). Conclusions: Within the limitations of this study, it can be concluded that LDS and UT HACs fabricated by fully digital workflow demonstrated clinically reliable treatment solutions. Summary: قد تؤثر التناقضات في التوافق الداخلي بين الترميمات المدعومة بالزرع وقاعدة التيتانيوم على تدفق اللاصق أثناء اللصق والاحتفاظ بالترميم. بالإضافة إلى ذلك، فإن التناقض الهامشي والفجوة الناتجة بين مكونات الترميمات المدعومة بالزرع تعمل بمثابة مخزن للبكتريا يحفز ويسرع تكوين الطبقه البكتيرية و التي يمكن أن تؤدي إلى التهاب الأنسجة المحيطة بالزرعة؛ ومع ذلك، لا يوجد أدلة واضحة فيما يتعلق بأفضل المواد الترميمية التي تمنح التكيف الهامشي والملاءمة الداخلية الأكثر فعالية. لذلك أجريت هذه الدراسة لتقييم الملائمة الداخلية والتكيف الهامشي بين تيجان الدعامات السيراميك الهجينة المثبتة على قاعدة التيتانيوم. تم احاطة أثني عشرة من نظيرالزرعات المصنوعة من التيتانيوم براتنجات الإيبوكسي لتتلقي تيجان الدعامات الهجينة باستخدام نظام العمل الرقمي. اربعه وعشرون من تيجان الدعامات الهجينة تم تقسيمها بشكل عشوائي الي مجموعتين متساويين في العدد كل مجموعه بها اثني عشر ترميمه مجموعة: مركبات ثنائية سيليكات الليثيوم ومجموعة: مركبات زركونيا متعددة الطبقات فائقة الشفافية. تم خرط تيجان الدعامات الهجينة باستخدام ماكينة خراطة ذات خمسة محاور لخراطة ثقب المسمار الخاص بالترميم. تم اختبار الملائمة الداخلية بين تيجان الدعامات الهجينة وقواعد التيتانيوم باستخدام تقنية النسخ المتماثل وتم قياس التكيف الهامشي باستخدام المجهر المجسم. أظهر التحليل الإحصائي بأنه لم يكن هناك فروق ذات دلالة إحصائية من حيث متوسط الفجوات الداخلية لمجموعة مركبات ثنائية سيليكات الليثيوم (43.89 ± 8.02 مم) و مجموعة مركبات زركونيا متعددة الطبقات فائقة الشفافية (71.62 ± 12.56 مم) ولم تكن هناك فروق ذات دلالة إحصائية في متوسط الفجوات الهامشية بين مجموعة ثنائية سيليكات الليثيوم (94.00 ± 6.51) ومجموعة الزركونيا متعددة الطبقات فائقة (43.77 ± 6.00). ونتيجة لذلك، فإن تيجان الدعامات الهجينة المصنوعة من ثنائي سيليكات الليثيوم والمواد الترميمية متعددة الطبقات فائقة الشفافية من الزركونيا والتي تم خراطتها بواسطة آلات خرط ذات خمسة محاور باستخدام نظام عمل رقمي أظهرت حلاً علاجيًا موثوقًا به ومرضيًا من الناحية الجمالية.
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Home library Call number Status Barcode
Thesis Thesis قاعة الرسائل الجامعية - الدور الاول المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.09.09.M.Sc.2024.Ma.I (Browse shelf(Opens below)) Not for loan 01010110090255000

Thesis (M.Sc)-Cairo University, 2023.

Bibliography: pages 93-105.

Aim: Evaluating the internal fit and marginal adaptation between ultra-translucent multilayered zirconia (UT) and lithium disilicate (LDS) implant-supported hybrid abutment crowns (HACs) and Ti base.
Methodology: A total of 24 implant‐supported hybrid abutment crowns on 12 titanium implant analogues were manufactured by a fully digital workflow. The HACs were divided into two equal groups (n=12). Group LDS and group UT HACs. Internal fit and marginal adaptation of the HACs were measured using the replica technique and stereomicroscope, respectively. Then, the results of both groups were statistically analysed.
Results: No significant difference was found in the mean internal and marginal gaps between group LDS (43.89 µm ± 8.02 and 94.00 µm ± 6.51, respectively) and group UT (71.62 µm ± 12.56 and 43.77 µm ± 6.00, respectively).
Conclusions: Within the limitations of this study, it can be concluded that LDS and UT HACs fabricated by fully digital workflow demonstrated clinically reliable treatment solutions.

قد تؤثر التناقضات في التوافق الداخلي بين الترميمات المدعومة بالزرع وقاعدة التيتانيوم على تدفق اللاصق أثناء اللصق والاحتفاظ بالترميم. بالإضافة إلى ذلك، فإن التناقض الهامشي والفجوة الناتجة بين مكونات الترميمات المدعومة بالزرع تعمل بمثابة مخزن للبكتريا يحفز ويسرع تكوين الطبقه البكتيرية و التي يمكن أن تؤدي إلى التهاب الأنسجة المحيطة بالزرعة؛ ومع ذلك، لا يوجد أدلة واضحة فيما يتعلق بأفضل المواد الترميمية التي تمنح التكيف الهامشي والملاءمة الداخلية الأكثر فعالية. لذلك أجريت هذه الدراسة لتقييم الملائمة الداخلية والتكيف الهامشي بين تيجان الدعامات السيراميك الهجينة المثبتة على قاعدة التيتانيوم.
تم احاطة أثني عشرة من نظيرالزرعات المصنوعة من التيتانيوم براتنجات الإيبوكسي لتتلقي تيجان الدعامات الهجينة باستخدام نظام العمل الرقمي. اربعه وعشرون من تيجان الدعامات الهجينة تم تقسيمها بشكل عشوائي الي مجموعتين متساويين في العدد كل مجموعه بها اثني عشر ترميمه مجموعة: مركبات ثنائية سيليكات الليثيوم ومجموعة: مركبات زركونيا متعددة الطبقات فائقة الشفافية. تم خرط تيجان الدعامات الهجينة باستخدام ماكينة خراطة ذات خمسة محاور لخراطة ثقب المسمار الخاص بالترميم. تم اختبار الملائمة الداخلية بين تيجان الدعامات الهجينة وقواعد التيتانيوم باستخدام تقنية النسخ المتماثل وتم قياس التكيف الهامشي باستخدام المجهر المجسم.
أظهر التحليل الإحصائي بأنه لم يكن هناك فروق ذات دلالة إحصائية من حيث متوسط الفجوات الداخلية لمجموعة مركبات ثنائية سيليكات الليثيوم (43.89 ± 8.02 مم) و مجموعة مركبات زركونيا متعددة الطبقات فائقة الشفافية (71.62 ± 12.56 مم) ولم تكن هناك فروق ذات دلالة إحصائية في متوسط الفجوات الهامشية بين مجموعة ثنائية سيليكات الليثيوم (94.00 ± 6.51) ومجموعة الزركونيا متعددة الطبقات فائقة (43.77 ± 6.00). ونتيجة لذلك، فإن تيجان الدعامات الهجينة المصنوعة من ثنائي سيليكات الليثيوم والمواد الترميمية متعددة الطبقات فائقة الشفافية من الزركونيا والتي تم خراطتها بواسطة آلات خرط ذات خمسة محاور باستخدام نظام عمل رقمي أظهرت حلاً علاجيًا موثوقًا به ومرضيًا من الناحية الجمالية.

Issues also as CD.

Text in English and abstract in Arabic & English.