Use of slurry infiltrated fiber concrete (SIFCON ) of retrofitting reinforced concrete beams deficient in shear / Ibtsam Ahmed Aly ; Supervised Ashraf Adel Shawky , Hamed M. Mahamoud

By: Contributor(s): Material type: TextTextLanguage: eng Publication details: Cairo : Ibtsam Ahmed Aly , 2010Description: 100P. : charts , facsimiles ; 30cmOther title:
  • استخدام الفيبر المخترقة بالمونة الأسمنتية فى معالجة شروخ القص فى الكمرات الخرسانية المسلحة [Added title page title]
Subject(s): Online resources: Available additional physical forms:
  • Issued also as CD
Dissertation note: Thesis (M.Sc.) - Cairo University - Faculty of Engineering - Department of Civil Engineering Summary: This reports on the behavior of shear - deficient Rc beams repaired with slurry infiltrated fiber concrete (SIFCON) jackets . The parameters investigated included the type of the beam (rect. - flanged ) and (Vf) (0,2%, 4% and 6%) . All of the 8 beams (rect. - flanged) were tested in equal third - point loading .6 beams were initially tested until the first shear crack appeared while two specimens (rect. - flanged) were tested until failure under shear load
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Home library Call number Copy number Status Barcode
Thesis Thesis قاعة الرسائل الجامعية - الدور الاول المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.13.05.M.Sc.2010.Ib.U (Browse shelf(Opens below)) Not for loan 01010110052993000
CD - Rom CD - Rom مخـــزن الرســائل الجـــامعية - البدروم المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.13.05.M.Sc.2010.Ib.U (Browse shelf(Opens below)) 52993.CD Not for loan 01020110052993000

Thesis (M.Sc.) - Cairo University - Faculty of Engineering - Department of Civil Engineering

This reports on the behavior of shear - deficient Rc beams repaired with slurry infiltrated fiber concrete (SIFCON) jackets . The parameters investigated included the type of the beam (rect. - flanged ) and (Vf) (0,2%, 4% and 6%) . All of the 8 beams (rect. - flanged) were tested in equal third - point loading .6 beams were initially tested until the first shear crack appeared while two specimens (rect. - flanged) were tested until failure under shear load

Issued also as CD